Lambrecht PRO-Modbus 14523 Скачать руководство пользователя страница 9

(14523/14524) PRO-Modbus 

  

 

     Manual

Manual
Wind Sensors PRO-Modbus (14523/14524)

31501 Global radiation 

instantaneous values 
(High-WORD)
(temperature compen-
sated)

W/m²

100

2 decimal places
Registers 31501 + 31502 can 
only be read out together 
(function code 0x04)

LONG

0x04

Big-Endian 
WORD

31502 Global radiation 

instantaneous values 
(Low-WORD)
(temperature compen-
sated)

0x04

Big-Endian 
WORD

31591 Global radiation 

instantaneous values 
(High-WORD)
(uncompensated)

W/m²

100

2 decimal places
Registers 31591 + 31592 can 
only be read out together 
(function code 0x04)

LONG

0x04

Big-Endian 
WORD

31592 Global radiation 

instantaneous values 
(Low-WORD)
(uncompensated)

0x04

Big-Endian 
WORD

10.8.1   

Mapping register PRO-Modbus

Register 
address

Register value

Unit

Factor

Description

46001

30001 Register address 1

Wind speed instantaneous value

INT

46002

30002 Register address 1

Wind speed average value since last retrieval

INT

46003

30003 Register address 1

Wind speed maximum value 

INT

46004

30004 Register address 1

Wind speed minimum value

INT

46005

30201 Register address 1

Wind direction instantaneous value

INT

46006

30202 Register address 1

Wind direction average value since last retrieval

INT

46007

30203 Register address 1

Wind direction maximum value

INT

46008

30204 Register address 1

Wind direction minimum value

INT

9

Содержание PRO-Modbus 14523

Страница 1: ...easuring range of 60 m s low starting values of 0 5 m s high resolution of measuring values very low needs of maintenance Standards EMC acc to EN 61000 6 2 EN 61000 6 4 EN 61000 4 2 3 4 5 6 11 Namur N...

Страница 2: ...an undisturbed terrain of this kind does not exist the sensor must be put up at a height of at least 5 m above the obstacle height If the sensor must be installed on a roof top the place of instal lat...

Страница 3: ...orientation select a landmark which is as far as possible up north with regard to the nal position of the wind direction sensor The reference point can be selected using a topographical map 1 25000 T...

Страница 4: ...14523 14524 PRO Modbus Manual Manual Wind Sensors PRO Modbus 14523 14524 8 Wiring diagram 4...

Страница 5: ...14523 14524 PRO Modbus Manual Manual Wind Sensors PRO Modbus 14523 14524 9 Dimensional drawings Accessory optional Mast adapter Id No 32 14567 008000 5 15 P51 69 P M27x1 5...

Страница 6: ...234 is transmitted in the order 0x12 0x34 Example Big Endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 10 2 Device address The addresses 1...

Страница 7: ...mal place INT 30202 Wind direction average value since last retrieval 10 1 decimal place INT 30203 Wind direction maximum value 10 1 decimal place INT 30204 Wind direction minimum value 10 1 decimal p...

Страница 8: ...tocon guration is started with the data logger met LOG it queries the available mapping registers on each COM interface in the device address range 1 25 For this purpose the number of mapping register...

Страница 9: ...Big Endian WORD 31592 Global radiation instantaneous values Low WORD uncompensated 0x04 Big Endian WORD 10 8 1 Mapping register PRO Modbus Register address Register value Unit Factor Description 4600...

Страница 10: ...delivery 1 sensor without cable Connectable to Lambrecht meteo data loggers power supply units user speci c evaluation systems not included in delivery Parameters Wind direction 14523 Wind speed 14524...