background image

(14523/14524) PRO-Modbus 

  

 

     Manual

Manual
Wind Sensors PRO-Modbus (14523/14524)

PRO-Modbus · Advantages at a glance

► wear-free, precise data acquisition
► high reliability and longevity
► cup rotor made of seawater-resistant aluminium
► for highest capacity
► simple installation for mast, fl ange and bore
► practical cable plug connection

Descriptions

  outstanding protection against electrostatic discharge for 

operation in lightning-prone regions

  wide range of operating for all-year application in most 

climatic zones due to integrated, regulated heating

  especially robust due to reinforced axis

  very high measuring range of 60 m/s

  low starting values of < 0.5 m/s

  high resolution of measuring values

  very low needs of maintenance

Standards

►  EMC acc. to EN 61000-6-2, EN 61000-6-4, 
 

EN 61000-4-2, -3, -4, -5, -6, -11, 

 

Namur NE-21

►  VDE 0100

►  WMO No. 8

►  VDI 3786 part 2

Content

1. 

Warranty

2. 

Initial operation

3. 

Maintenance

4. 

Principles of installation

5. 

Setting up the North Direction 

 

for the wind direction sensor

6. 

Electrical connection

7. 

Heating

8. 

Wiring diagram

9. 

Dimensioned drawings

10. 

Modbus-protocol

10.1 

Data encoding 

10.2 

Device-address

10.3 

Standard confi guration - Default

10.4 

Modbus command set

10.5 

Measured value and parameter registers

10.6 

Sensor parameters / Confi guration parameters

10.7 

Mapping register for autoconfi guration 

10.8 

Autoconfi guration

10.8.1  Mapping register PRO-Modbus
11. 

Technical data

1

Содержание PRO-Modbus 14523

Страница 1: ...easuring range of 60 m s low starting values of 0 5 m s high resolution of measuring values very low needs of maintenance Standards EMC acc to EN 61000 6 2 EN 61000 6 4 EN 61000 4 2 3 4 5 6 11 Namur N...

Страница 2: ...an undisturbed terrain of this kind does not exist the sensor must be put up at a height of at least 5 m above the obstacle height If the sensor must be installed on a roof top the place of instal lat...

Страница 3: ...orientation select a landmark which is as far as possible up north with regard to the nal position of the wind direction sensor The reference point can be selected using a topographical map 1 25000 T...

Страница 4: ...14523 14524 PRO Modbus Manual Manual Wind Sensors PRO Modbus 14523 14524 8 Wiring diagram 4...

Страница 5: ...14523 14524 PRO Modbus Manual Manual Wind Sensors PRO Modbus 14523 14524 9 Dimensional drawings Accessory optional Mast adapter Id No 32 14567 008000 5 15 P51 69 P M27x1 5...

Страница 6: ...234 is transmitted in the order 0x12 0x34 Example Big Endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 10 2 Device address The addresses 1...

Страница 7: ...mal place INT 30202 Wind direction average value since last retrieval 10 1 decimal place INT 30203 Wind direction maximum value 10 1 decimal place INT 30204 Wind direction minimum value 10 1 decimal p...

Страница 8: ...tocon guration is started with the data logger met LOG it queries the available mapping registers on each COM interface in the device address range 1 25 For this purpose the number of mapping register...

Страница 9: ...Big Endian WORD 31592 Global radiation instantaneous values Low WORD uncompensated 0x04 Big Endian WORD 10 8 1 Mapping register PRO Modbus Register address Register value Unit Factor Description 4600...

Страница 10: ...delivery 1 sensor without cable Connectable to Lambrecht meteo data loggers power supply units user speci c evaluation systems not included in delivery Parameters Wind direction 14523 Wind speed 14524...

Отзывы: