Operating Instructions (16461)
BLUESONIC
10
Wilh. Lambrecht GmbH Germany
10
Maintenance
In principle the equipment is maintenance-free.
However, it is recommended to carry out a functional test on an annual basis. When doing
so, pay attention to the following points:
•
Visual inspection of the equipment for soiling
•
Check the sensors by carrying out a measurement request
11
Technical Data
Power supply:
24 VDC ± 10 %
Current consumption and power input - sensor:
approx. 50 mA / 1.2 VA at 24 VDC
Current consumption and power input with heating:
approx. 10 A / 240 VA at 24 VDC
Dimensions including mounting bracket:
Ø 150 mm, height 145 mm
Weight including mounting bracket, excluding connection cable:
approx. 1.63 kg
Fastening:
Mast with Ø 50 mm
Protection class:
III (SELV)
Protection type:
IP 65
Storage conditions
Permissible storage temperature:
-55... +80 °C
Permissible relative humidity:
0... 95 % RH non-condensing
Operating conditions
Permissible operating temperature: -40... +60 °C (with heating)
Permissible relative humidity:
0 ... 100 % RH
Housing:
seawater-resistant aluminium AlMg3Si
BLUESONIC
NMEA
Id-No.: 00.16461.000 010
Interface RS422 NMEA / Talker
Data bits:
8
Stop bit:
1
Parity:
No
Baud rate:
4800
BLUESONIC
ANALOG
Id-No.: 00.16461.000 040
Interface circuits:
4…20 mA
Maximum load:
300
Ω
Resolution:
16 Bit
Update rate:
1 Hz
Scaling wind speed:
4…20 mA
≙
0…65 m/s
Scaling wind direction:
4…20 mA
≙
0°...360°