background image

EN

51

cod. 3541S870  -  Rev. 03  -  07/2020

JEREZ ECO

• 

Read the warnings contained in this 

manual carefully. 

• 

Once the unit is installed, describe its 

operation to the user and give them 

this manual. The manual is an integral 

part of the product and must be kept in 

a safe, accessible place for future refe-

rence. 

• 

Installation and maintenance must be 

performed by a registered technician, in 

accordance with current standards and 

the manufacturer's instructions. Tampe-

ring with the sealed adjustment devices 

is prohibited. 

• 

Improper installation or lack of appro-

priate maintenance may result in pro-

perty damage or injury. The manufactu-

rer will not be liable for damage caused 

by improper installation or use or, in any 

case, for failure to comply with the in-

structions. 

• 

Before performing any cleaning or 

maintenance operations, unplug the 

unit from the mains power supply using 

the power switch or another cut-off de-

vice. 

• 

In the event of a malfunction or impro-

per operation, unplug the unit and have 

it repaired by qualified personnel. Only 

contact registered technicians. The unit 

must only be repaired, and its compo-

nents replaced, by registered techni-

cians using original replacement parts. 

Otherwise the safety of the unit may be 

compromised. 

• 

This unit may only be used for the pur-

pose for which it was expressly desig-

ned. Any other use must be considered 

inappropriate, and therefore hazardous. 

• 

The packing materials are a potential 

source of danger, and must be kept out 

of reach of children. 

• 

The unit can be used by children aged 

at least 8 years and by persons with 

reduced physical, sensory or mental 

capabilities, or lacking experience or 

the necessary knowledge, only if un-

der supervision or they have received 

instructions on its safe use and the re-

lated risks. Children must not play with 

the unit. Cleaning and maintenance in-

tended to be done by the user can be 

carried out by children aged at least 8 

years only if under supervision.. 

• 

Dispose of the unit and its accessories 

in accordance with current standards. 

• 

The images contained in this manual 

are  a  simplified  representation  of  the 

GENERAL WARNINGS

Содержание JEREZ ECO

Страница 1: ...1 203 40 90 391 204 63 61 4712 77 13 04 4742 52 20 81 3519 55 03 13 495 268 04 70 8152 59 64 93 8552 20 53 41 831 429 08 12 3843 20 46 81 383 227 86 73 3812 21 46 40 4862 44 53 42 3532 37 68 04 8412 2...

Страница 2: ...operation unplug the unit and have it repaired by qualified personnel Only contact registered technicians The unit must only be repaired and its compo nents replaced by registered techni cians using...

Страница 3: ...0 C product Such representations may in clude slight insignificant differences with respect to the product supplied APPLIANCE INTENDED FOR DOME STIC USE NOT VALID FOR INDU STRIAL USE 1 USER S MANUAL 5...

Страница 4: ...3 4 Replacing the batteries 4 Also verify that the batteries are sufficiently charged for heater operation 1 3 1 Turning the unit on Turn the knob to the required water heating level The unit will be...

Страница 5: ...Defective gas valve Check and or change the gas valve Activation of the over temperature protection Damaged or badly positio ned heating sensor Check that the heating sensor is properly installed and...

Страница 6: ...nts space must be allowed for removing the casing and performing normal maintenance activities fig 5 Minimum distances A On each side 2cm B 50cm C In front 2cm 2 3 Assembling the heater Before assembl...

Страница 7: ...S II2H3B P AT CH II2E3B P DE LU SI GR SK CZ LT 2HM 2E 2H 2HS 2ELW G20 G230 20 mbar 21 1 18 9 8 1 6 56 mg kWh 19 1905G80032 3V W IPX4D Suitable for operation in a partially protected place MADE IN CHIN...

Страница 8: ...the unit s consumption See the technical data table section 4 5 In installations with an appro ved flexible pipe for LPG pay special attention to the fol lowing The pipe must comply with applicable re...

Страница 9: ...nt re gulations FERROLI declines all liability for property da mage or injuries caused by unauthorized persons tam pering with the unit 3 1 ADJUSTMENTS 3 1 1 Gas conversion Conversion of the unit to a...

Страница 10: ...er on the floor with the connections facing down If the above instructions are not observed there may be risk of suffocation or poisoning due to gas or fumes escaping danger of fire or explosion Also...

Страница 11: ...he casing and exterior parts of the heater using soapy water if neces sary Do not use abrasive detergents or solvents 3 3 2 Opening the casing To open the casing 1 Unscrew the A screws 2 Rotate the ca...

Страница 12: ...61 cod 3541S870 Rev 03 07 2020 JEREZ ECO 4 TECHNICAL DATA AND CHARACTERISTICS 4 1 Dimensions and connections fig 19 Dimensions and connections JEREZ ECO 6 fig 20 Dimensions and connections JEREZ ECO...

Страница 13: ...07 2020 JEREZ ECO fig 21 Dimensions and connections JEREZ ECO 14 1 1 2 gas inlet 2 1 2 cold water inlet 3 1 2 domestic hot water outlet 4 2 Overview and main components fig 22 Overview JEREZ ECO 6 fig...

Страница 14: ...ater outlet 4 Combustion chamber assembly 5 Gruppo bruciatori 6 Exhausthood 7 Copper heat exchanger 8 Solenoid valve 9 Induction electrode 10 Ignition electrode 11 Flue gas sensor 12 Hot water tempera...

Страница 15: ...Maximum gas delivery G20 m3 h 1 25 2 23 2 84 Minimum gas delivery G20 m3 h 0 67 0 86 1 13 Burner injectors G230 n x 14 x 0 95 24 x 0 95 28 x 0 95 Gas supply pressure G230 mbar 20 20 20 Maximum gas del...

Страница 16: ...r as placed on the market MAX MAX MAX Sound power level LWA dB 57 58 59 Emissions of nitrogen oxides NOx mg kWh 52 37 42 ErP product fiche Models LPG Trademark LAMBORGHINI Type Conventional water heat...

Страница 17: ...4842 92 23 67 3842 65 04 62 8332 68 02 04 861 203 40 90 391 204 63 61 4712 77 13 04 4742 52 20 81 3519 55 03 13 495 268 04 70 8152 59 64 93 8552 20 53 41 831 429 08 12 3843 20 46 81 383 227 86 73 3812...

Отзывы: