1.4.2 Setting the temperature
Turn the water temperature selector clockwise to incre-
ase the temperature, or counterclockwise to decrease it.
fig. 4 -
Setting the temperature
1.5 Faults
Once the adjustments described above have been made,
the heater is ready to operate automatically. When a hot
water tap is opened, an intermittent discharge is genera-
ted on the ignition electrode to light the burner.
All electronic models have an ionization electrode built
into the burner to monitor flame presence. If a malfun
-
ction or lack of gas causes the heater to turn off, close
the hot water tap.
It is then necessary to eliminate the fault or obstacle pre-
venting the gas from reaching the heater, e.g., inadver-
tent closing of the gas cock, empty gas cylinder, etc.
To reactivate the heater, close and open the hot water
tap.
If no hot water is produced after eliminating the cause
and opening the hot water tap, repeat the process.
If the problem persists, call the technical support center.
Table 1 - Faults
The burner
does not
ignite
Absence of
gas
Check the flow of
gas to the heater,
and make sure
the pipes have
been purged.
Failure of the
ignition/detec-
tion electrode
Check the elec-
trode cable, and
make sure it's
properly con-
nected and free of
deposits.
Defective gas
valve
Check and/or
change the gas
valve.
Activation of
the over-
temperature
protection
Damaged or
badly positio-
ned heating
sensor
Check that the
heating sensor is
properly installed
and operating
and/or change it.
Activation of
the flue gas
thermostat
(after this
operation,
the unit is
reset by tur-
ning on the
tap, and the
thermostat
cools off).
Flue gas
thermostat
contact open
Check the ther-
mostat.
Cables
disconnected
Check the con-
nections.
Thermostat
obstructed
or incorrectly
sized
Check the ther-
mostat.
Probe discon-
nected
Check the con-
nection or change
the probe.
2 INSTALLATION MANUAL
2.1 General information
The heater may only be instal-
led by an authorized technician,
in accordance with all instruc-
tions contained in this manual,
standard UNE 26, and local in-
stallation and exhaust regula-
tions.
2.2 Location
Make sure the water heater chosen is the most suitable:
•
To adequately meet the system’s hot water require-
ments.
•
For the gas to be used (see water heater dataplate).
•
For the water supply pressure, necessary for operation
(see table of characteristics).
Make sure the room where the unit is installed meets
all the requirements of the Current Regulations. In
particular, this unit is an “open chamber” type and
must only be installed and operate in permanently
ventilated places. An insufficient supply of combu
-
stion air will compromise normal operation and the
evacuation of fumes. Also, the fumes forming under
these conditions are extremely harmful to health if