40
UK
EQUIPMENT
LMO EQUIPMENT
The release pushbutton on the equipment is the main component for accessing all the diagno-
stic functions (activation and deactivation) as well as for releasing the control and checking
device.
The release pushbutton has a multicoloured led which indicates the state of the control and
checking device during operation and when the diagnostic function is in use.
EQUIPMENT STATE INDICATORS
Description
Condition Colour sequence
Colour sequence
Standby, other intermediate states
No light
Fuel preheating “on”, waiting time 5s.max
Yellow
Ignition stage Yellow, flashing
Yellow, flashing
Correct operation
Green
Incorrect operation, current level of
flame detector below permitted minimum Green, flashing
Green, flashing
Drop in voltage
Alternating yellow red
Burner lock out
Red
Fault
Red, flashing
Stray light before burner ignition
Alternating green red
Rapid flashing for diagnostics
Red, rapid flashing
If the burner is locked out, there will be a steady red light on the lock out pushbutton.
By pressing the transparent pushbutton, the control and checking device will be released.
By pressing it for more than 3 seconds, the diagnosis stage will be activated (red light flashes rapidly).
The table below describes the causes of the lock out or fault in relation to the number of flashes (always
red). The diagnosis function is interrupted by pressing the release button for at least 3 seconds.
DIAGNOSIS OF LMO EQUIPMENT FAULTS AND LOCK OUT
Visual indication
Possible causes
2
flashes
No flame signal
- Faulty fuel valves
- Faulty flame detector
- Incorrect burner setting, no fuel
- No ignition
3
flashes
Not used
4
flashes
Stray light on ignition
5
flashes
Not used
6
flashes
Not used
7
flashes
No flame signal during operation
- Faulty fuel valves
- Faulty flame detector
- Incorrect burner setting, no fuel
8
flashes
Anomalies in fuel preheating time
9
flashes
Not used
10
flashes
Incorrect electrical connection or damage to equipment
Содержание ECO 8
Страница 2: ......
Страница 104: ...104 RU LAMBORGHINI CALORECLIMA 2004 108 CE 2006 95 CE 105 108 109 110 111 112 113 114 117 119 120 121 123...
Страница 105: ...105 RU a...
Страница 106: ...106 RU b c d CO2 CO2 CO2...
Страница 107: ...107 RU 3 Lamborghini Calor S p A 24 24 10...
Страница 111: ...111 RU 2 4 3 4 5 1 A B C D B 60...
Страница 113: ...113 RU 15 3 10 13 15 10 10 2 1 18 2 2 ECO 8 ECO 10 ECO 15 ECO 20 ECO 15 2 ECO 20 2 t1 t2 t3...
Страница 115: ...115 RU LMO 14 16 7 ECO 15 ECO 20 CO F FR IG LS M MB TA TC TR TS VE 230 50...
Страница 117: ...117 RU 17 ECO 8 10 15 20 13 12 ECO 8 10 15 20 12 2 42 27 ECO 15 2 ECO 20 2 10 2 1 18 2 2 61 1 42 2 27 30 2 7 14 2...
Страница 119: ...119 RU 10 O 13 12 10 16 13 12...
Страница 120: ...120 RU LMO on 5 3 3 LMO 2 3 4 5 6 7 8 9 10...
Страница 122: ...122 RU 23 22 32 14 34...
Страница 123: ...123 RU a b a b c a b c a b a b a b c b c b b...