RAGGIO C
192
EN
cod. 3541V280 - Rev. 01 - 04/2021
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the
setting of the parameter given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given
in brackets is modified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
To return to the service menu, touch the arrow at the top left of the screen.
Menu [Transparent parameters P]
A
By selecting a parameter on the screen, the possible values will be shown. If the values
shown do not match those indicated in the corresponding "Range" column, check that the
parameter
B01
is correctly set to
RRT
.
B28
Flowmeter sensitivity fac-
tor
0 ÷ 60 (0 = disabled)
20
B29
Restoring Factory Values Set the value to 10
-
Code
Description
Range
Default
P30
Heating ramp
1 ÷ 20°C/minute
4°C/minute
P31
Virtual setpoint min.
temperature
0
= Deactivated
1 ÷ 80°C
0
P32
Heating standby time 0 ÷ 10 minutes
4
P33
Heating Post-Circula-
tion
0 ÷ 255 minutes
15
P34
Pump operation
Fixed flow rate on call
Fixed continuous flow rate
Adaptive flow rate on call
Adaptive continuous flow rate
Adaptive flow rate on call
P35
Modulating pump min.
speed
30 ÷ 100%
30%
P36
Modulating pump start
speed
90 ÷ 100%
90%
P37
Modulating pump
max. speed
90 ÷ 100%
100%
P38
Pump deactivation
temperature during
Post-Circulation
0 ÷ 100°C
55°C
P39
Pump activation hys-
teresis temperature
during Post-Circula-
tion
0 ÷ 100°C
25°C
P40
Heating user max. set-
point
20 ÷ 90°C
80°C
P41
Max. output in heating 0 ÷ 100%
80%
P42
Burner shutdown in
DHW
Fixed
Linked to setpoint
Solar
Fixed
P43
Comfort mode activa-
tion temperature
0 ÷ 80°C
40°C
P44
Comfort mode deacti-
vation hysteresis
0 ÷ 20°C
20°C
P45
DHW standby time
30 ÷ 255 seconds
120
Code Description
Range