iXinox 24 C
27
EN
cod. 3541N452EN - Rev. 03 - 03/2020
P44
Not used (b01=1)
Do not modify
0
Primary setpoint (b01=2)
70-85°C (Primary circuit temperature adjustment in DHW)
80°C
Comfort deactivation hysteresis
(b01=3)
0-20°C
20°C
Primary setpoint (b01=4)
70-85°C (Primary circuit temperature adjustment in DHW)
80°C
P45
DHW standby time (b01=1)
30-255 seconds
60 seconds
DHW standby time (b01=2)
30-255 seconds
120 seconds
DHW standby time (b01=3)
30-255 seconds
120 seconds
DHW standby time (b01=4)
30-255 seconds
120 seconds
P46
DHW user max. setpoint (b01=1) 40-70°C
55°C
DHW user max. setpoint (b01=2) 40-70°C
65°C
DHW user max. setpoint (b01=3) 40-70°C
55°C
DHW user max. setpoint (b01=4) 40-70°C
65°C
P47
DHW pump Post-Circulation
(b01=1)
0-255 seconds
50 seconds
DHW pump Post-Circulation
(b01=2)
0-255 seconds
30 seconds
DHW pump Post-Circulation
(b01=3)
0-255 seconds
30 seconds
DHW pump Post-Circulation
(b01=4)
0-255 seconds
30 seconds
P48
DHW maximum power (b02=1)
0-100%
100%
DHW maximum power (b02=2)
0-100%
100%
DHW maximum power (b02=3)
0-100%
94%
DHW maximum power (b02=4)
0-100%
100%
P49
Comfort1 standby time (b01=1)
0-100minutes
20 minutes
Not implemented (b01=2)
--
--
Not implemented (b01=3)
--
--
Not implemented (b01=4)
--
--
P50
Comfort2 standby time (b01=1)
0-100 minutes
42 minutes
Not implemented (b01=2)
--
--
Not implemented (b01=3)
--
--
Not implemented (b01=4)
--
--
P51
Solar deactivation temperature
(b01=1)
0-100°C
10°C
Setpoint deltaT (b01=2)
0-20°C
0°C
Solar deactivation temperature
(b01=3)
0-100°C
10°C
Setpoint deltaT (b01=4)
0-20°C
0°C
P52
Solar ignition temperature
(b01=1)
0-100°C
10°C
DHW ramp (b01=2)
1-20°C/minute
5°C/minute
Solar ignition temperature
(b01=3)
0-100°C
10°C
DHW ramp (b01=4)
1-20°C/minute
5°C/minute
P53
Solar standby time (b01=1)
0-255 seconds
10 seconds
No effect on adjustment (b01=2)
0-255 seconds
0 seconds
Solar standby time (b01=3)
0-255 seconds
10 seconds
No effect on adjustment (b01=4)
0-255 seconds
0 seconds
P54
Heating deltaT temperature adju-
stment (b01=1)
0-60°C
18°C
Heating deltaT temperature adju-
stment (b01=2)
0-60°C
18°C
Heating deltaT temperature adju-
stment (b01=3)
0-60°C
18°C
Heating deltaT temperature adju-
stment (b01=4)
0-60°C
18°C
Contents
Description
Range
Default