111
cod. 3541T630 - Rev. 04 - 12/2021
EN
DORA
200 HT - 260 HT
Parameter Description
Range
Default
Notes
P58
Use of the evaporator fan with the compres-
sor off
0 = OFF
1 = ON with manual speed
control
2 = ON with automatic speed
control
0
Modifiable (1)
P59
Evaporator fan speed (EC) with compressor
off
0÷100%
40%
Modifiable (1)
P60
Temperature difference 1 of evaporation of
the air for the calculation of the setpoint
1÷25°C
4°C
Modifiable (1)
P61
Temperature difference 2 of evaporation of
the air for the calculation of the setpoint
1÷25°C
2°C
Modifiable (1)
P62
Temperature difference 3 of evaporation of
the air for the calculation of the setpoint
1÷25°C
6°C
Modifiable (1)
P63
Temperature difference 4 of evaporation of
the air for the calculation of the setpoint
1÷25°C
3°C
Modifiable (1)
P64
Temperature difference 5 of evaporation of
the air for the calculation of the setpoint
1÷25°C
10°C
Modifiable (1)
P65
Temperature difference 6 of evaporation of
the air for the calculation of the setpoint
1÷25°C
18°C
Modifiable (1)
P66
Band 2 evaporator temperature proportional
regulation
1÷20°C
2°C
Modifiable (1)
P67
Band 3 evaporator temperature proportional
regulation
1÷20°C
9°C
Modifiable (1)
P68
Band 4 evaporator temperature proportional
regulation
1÷20°C
5°C
Modifiable (1)
P69
Band 5 evaporator temperature proportional
regulation
1÷20°C
10°C
Modifiable (1)
P70
Band 6 evaporator temperature proportional
regulation
1÷20°C
5°C
Modifiable (1)
P71
EC evaporator fan speed reduction for silent
mode
0÷40%
15%
Modifiable (1)
P72
EC fan speed regulator gain
1÷100
5
Modifiable (1)
(1) = NOT USABLE FOR THIS EQUIPMENT