cod. 3541T630 - Rev. 04 - 12/2021
110
EN
DORA
200 HT - 260 HT
Parameter Description
Range
Default
Notes
P22
Tank upper probe temperature for heating
element stop in photovoltaic mode
30÷80°C
75°C
Modifiable
P23
Photovoltaic supplement
0 = function excluded
1 = enabled
0
Modifiable
P24
Operating mode during Off-peak
0 = function excluded
1 = ECO 2 = Automatic
0
Modifiable
P25
Offset for tank upper probe
-25÷25°C
0°C
Modifiable
P26
Offset for tank lower probe
-25÷25°C
0°C
Modifiable
P27
Inlet air probe offset
-25÷25°C
0°C
Modifiable
P28
Offset for defrost probe
-25÷25°C
0°C
Modifiable
P29
Anti-legionella cycle activation time
0÷23 hours
23 hours
Modifiable
P30
Hysteresis on upper tank probe for heating
element operation
2÷20°C
7°C
Modifiable
P31
Working time of heat pump in Automatic
mode for calculating heating speed
10÷80 min
30 min
Modifiable
P32
Threshold on tank lower probe for heating
element switch-on in Automatic mode
0÷20°C
4°C
Modifiable
P33
EEV use
0 = not used
1 = used
0
Modifiable (1)
P34
Overheating calculation interval for EEV
with automatic control
20÷90s
30 s
Modifiable (1)
P35
Overheating set-point for EEV with
automatic control
-8 ÷15°C
4°C
Modifiable (1)
P36
Desuperheating set-point for EEV with
automatic control
60÷110°C
88°C
Modifiable (1)
P37
EEV opening step during defrosting (x10)
5÷50
15
Modifiable (1)
P38
EEV minimum opening step with automatic
control (x10)
3~45
9
Modifiable (1)
P39
EEV control mode
0 = automatic
1 = manual
0
Modifiable (1)
P40
EEV initial opening step with automatic
control / EEV opening set-point with manual
control (x10)
5÷50
25
Modifiable (1)
P41
AKP1 threshold for KP1 gain
-10÷10°C
-1°C
Modifiable (1)
P42
AKP2 threshold for KP2 gain
-10÷10°C
0°C
Modifiable (1)
P43
AKP3 threshold for KP3 gain
-10÷10°C
0°C
Modifiable (1)
P44
EEV KP1 gain
-10÷10
2
Modifiable (1)
P45
EEV KP2 gain
-10÷10
2
Modifiable (1)
P46
EEV KP3 gain
-10÷10
1
Modifiable (1)
P47
Max. inlet air temperature for heat pump
operation
30÷50°C
43°C
Modifiable
P48
Min. inlet air temperature for heat pump
operation
-10÷10°C
4°C
Modifiable
P49
Inlet air temperature threshold for setting the
electronic fan speed or two-speed AC
10÷40°C
25°C
Modifiable (1)
P50
Tank lower probe temperature for frost
protection
0÷15°C
12°C
Modifiable
P51
EC evaporator fan upper speed set-point
60÷100%
65%
Modifiable (1)
P52
EC evaporator fan lower speed set-point
10÷60%
40%
Modifiable (1)
P53
EC evaporator fan defrost speed setpoint
0÷100%
50%
Modifiable (1)
P54
Low pressure switch bypass time
1÷240 min
1
Modifiable (1)
P55
Band 1 evaporator temperature proportional
regulation
1÷20°C
4°C
Modifiable (1)
P56
Differential temperature with activation of
maximum speed
P57÷20°C
2°C
Modifiable (1)
P57
Differential temperature with deactivation of
maximum speed
1°C÷P56
1°C
Modifiable (1)