83-515-000 Rev. A
59
7.10 SINGLE BYTE COMMANDS
7.10.1 General
Single byte commands are commands in which all the necessary data for the supply to act
upon is contained in a single byte. Single byte commands will be executed immediately by the
supply. If the command requires data to be sent to the HOST PC or IEEE Board (see sections
7.10.4 and 7.10.3.1) that response will be transmitted immediately with no delay due to any
software overhead. With the exception of the Disconnect from communications command, sec-
tion 7.10.3.1, commands must be sent by the HOST PC or IEEE Board 2 times in sequence for
verification. Alll have the most significant bit, D7, set to a logic 1. A CR, carriage return, char-
acter is not included in a single byte command. The RST command will not change any setting
made by a single byte command.
All Single Byte commands will be executed in 1 ms or less. This does not include any re-
sponse sent to the HOST/IEEE Board, which is dependent upon the response length and the
serial transmission speed (Baud rate).
7.10.2 Global commands without response
7.10.2.1 Disable MD Mode (MD MODE OPTION REQUIRED)
Disable is the default condition upon power up. The Hex value of the command is 0xA0.
Send it two times in sequence. All supplies, both the currently addressed supply and all
non-addressed supplies, will disable MD Mode as a result of this command.
7.10.2.2 Enable MD Mode (MD MODE OPTION REQUIRED)
Send to enable Multi Drop Mode. The Hex value of the command is 0xA1. Sent it two times
in sequence. When this command is sent, the supply will set SRQ retransmission to the
disable state; if you wish it to be enabled you must send the enable command. All supplies,
both the currently addressed supply and all non-addressed supplies, will enable MD Mode
as a result of this command.
7.10.2.3 Disable SRQ retransmission (MD MODE OPTION REQUIRED)
Disable is the default condition upon power up. The Hex value of the command is 0xA2.
Sent it two times in sequence. If the supply sends an SRQ it will only sent it 1 time. All sup-
plies, both the currently addressed supply and all non-addressed supplies, will disable
SRQ retransmission as a result of this command. All status registers will retain their data
when this command is sent.
7.10.2.4 Enable SRQ retransmission (MD MODE OPTION REQUIRED)
Enable retransmission of SRQs. This is only available when the Multi Drop Mode is en-
abled in the supply. The Hex value of the command is 0xA3. Send it two times in se-
quence. If the supply sends an SRQ it will be repeated on a timely basis, 10 ms plus 20 ms
times the supply address, until answered. All supplies, both the currently addressed supply
and all non-addressed supplies, will enable SRQ retransmission as a result of this com-
mand.
7.10.2.5 Enable FLT Bit in the SENA Register
The Hex value of the command is 0xA4. Send it two times in sequence.
Содержание 2U GENESYS 5kW
Страница 2: ......
Страница 3: ...GENESYS Manual Supplement FOR UNITS EQUIPPED WITH IEMD OPTION ALSO REFER TO MANUAL 83 030 200 IEMD...
Страница 8: ......
Страница 16: ...83 515 000 Rev A 9 CHAPTER 2 SPECIFICATIONS...
Страница 17: ...83 515 000 Rev A 10...
Страница 19: ...83 515 000 Rev A 12 2 13 GENESYSTM 5000W POWER SUPPLIES OUTLINE DRAWINGS...