background image

1/2" NPT**

3/4" NPT**

1"

1-1/4"

1-1/2" 

2" 

2-1/2" 

3" 

4" 

4"

6" 

6" 

8" 

10" 

12" 

16" 

20" 

JPX-0004

JPX-0010

JPX-0016

JPX-0028

JPX-0038

JPX-0060

JPX-0085

JPX-0130

JPX-0200

0.09

0.11

0.15 

0.27 

0.4 

0.8

0.8 

0.8 

1.6

0.3 

0.4 

0.6 

1.0 

1.5 

3.0

3.0 

3.0 

6.1 

22 

31 

40 

59 

85 

150 

194 

202 

327 

25 

37 

51 

77 

115 

221 

278 

290 

507 

10 

14 

18

27 

39 

68 

88 

92 

149 

11 

17 

23 

35 

52 

101 

126 

132 

231 

4-10

10-20

16-30

28-45 

38-65 

60-100 

85-145 

130-225 

200-325 

285-525 

450-825 

650-1200 

1160-2150 

1850-3400 

2650-4900 

4200-7800 

6700-12750 

1-2.5

2.5-4.5

4 -7 

7-10 

9-15

14-23

19-33

30-51

45-74

65-120 

102-187 

150-275

265-490 

420-775 

600-1115 

950-1775 

1520-2895

Models ending with "L" are low profile; "V" for vertical profile

Inlet/Outlet may also be specified with ANSI flanges or DIN flanges; JPX-0004 and JPX-0010 are

standard male, N.P.T. (BSP or JIS threads available); other models also available with optional threading

Maximum pressure rating: 

150 psi (10.3 bar); consult factory for higher pressure requirements

Pressure loss range: 

3 - 12 psi (.2 -.8 bar) 

Maximum particle size: 

JPX-0016 and smaller – .25 inch (6 mm); all other models – .375 inch (9 mm)

Material (standard carbon steel): 

Domes – A 285C/516 GR70, .25 inch (6 mm) minimum thickness         

    

Other parts – A-36, A-53B or other quality grade, .25 inch (6 mm) minimum thickness; special  

      

    

coatings and other materials available - consult factory

Paint coating:

 Acrylic urethane, spray-on royal blue

1"

1"

1"

1-1/2"

1-1/2"

1-1/2"

1-1/2"

1-1/2"

1-1/2"

Specifications

Flow Range

U.S. gpm

m

3

/hr

gal

liters

lbs.

kg

kg

lbs

Model*

Weight

Weight

with Water

Collection

Chamber Capacity

Inlet/Outlet

Grooved

Coupling**

1-1/2"

1-1/2"

1-1/2"

1-1/2"

2"

2"

3"

3"

JPX-0004

JPX-0010

JPX-0016

JPX-0028

JPX-0038

JPX-0060

JPX-0085

JPX-0130

JPX-0200

JPX-0285

JPX-0450

JPX-0650

JPX-1160

JPX-1850

JPX-2650

JPX-4200

JPX-6700

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

Page 3

JPX-0285-L

JPX-0285-V

JPX-0450-L

JPX-0450-V

JPX-0650-L

JPX-0650-V

JPX-1160-L

JPX-1160-V

JPX-1850-L

JPX-1850-V

JPX-2650-L

JPX-2650-V

JPX-4200-L

JPX-4200-V

JPX-6700-L

JPX-6700-V

Purge Size

Male N.P.T.

2.1 
5.4 

2.8 
6.7 

4.3 

10.4 

8.6 

20.5 

15.0 
31.5 

23.5 
51.1 

52.2 
99.3 

81.0 

162.3

7.9 

20.5 

10.6 
25.4 

16.3 
39.4 

32.6 
77.6 

56.8 

119.2 

89.0 

193.4 

197.6 
375.9 

306.6 
614.4

510 
474 

738 
697 

929 
898 

1391 
1411 

1853 
1937 

3077 
3254 

5074 
5574 

7808 
8527 

232 
216 

336 
317 

422 
408 

632
641 

842 
880 

1399 
1479 

2306 
2534 

3549 
3876

820 
758 

1202 
1132 

1627 
1554 

2716 
2665 

3991 
3951

6269 
6287 

11791 
11944 

18660 
18855

373 
345 

546 
515 

740 
706 

1235 
1211 

1814 
1796 

2850 
2858 

5360 
5430 

8482 
8571

*

**

Flow vs. Pressure Loss 

I

Q

K

L

M

N

O

P

J

H

G

F

E

D

C

B

12

Pressure Loss (psi)

3

5

10

20

30

40

50

100

10,000

5,000

3,000

2,000

1,000

500

300

200

10

5

Flow Rate (U.S. gpm)

A

3

5

7

9

10

15

20

25

50

75

100

150

200

250

500

750

1,

0

0

0

1,

5

0

0

2,

0

0

0

2,

5

0

0

3,000

Pressure Loss (bar)

.2

1.0

.8

.6

.4

Flow Rate (m

3

/hr)

Содержание JPX

Страница 1: ...Rigid couplings for fast and easy internal access Swirlex internal accelerating slots for optimum solids removal performance patented optional annular transfer ring for handling larger solids fibrous materials Vortube for enhanced solids separation collection patented Grooved inlet outlet connections for easy installation optional flanged connections also available In line inlet outlet configurati...

Страница 2: ...ge valve for servicing Grooved end connections at inlet outlet for fast secure easy installation Optional ANSI or DIN flanges also available Pressure gauges with petcock valves included as standard to monitor proper flow range see Flow vs Pressure Loss page 3 Outlet Inlet Internal Swirlex tangential slots accelerate flow to maximize separation of solids with reduced pressure loss Particles are sep...

Страница 3: ...terials available consult factory Paint coating Acrylic urethane spray on royal blue 1 1 1 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 Specifications Flow Range U S gpm m3 hr gal liters lbs kg kg lbs Model Weight Weight with Water Collection Chamber Capacity Inlet Outlet Grooved Coupling 1 1 2 1 1 2 1 1 2 1 1 2 2 2 3 3 JPX 0004 JPX 0010 JPX 0016 JPX 0028 JPX 0038 JPX 0060 JPX 0085 JPX 0130 JPX 0200 JPX 02...

Страница 4: ...ressure of at least 5 psi 3 bar Winterizing is important if the LAKOS Separator is to remain idle in freezing temperatures Drain liquid as necessary to avoid expansion of water to ice and related damages Maintenance Purging Installation Instructions 1 LAKOS JPX Separators must be purged regularly to remove the separated solids from the temporary collection chamber 2 All purge hardware should be in...

Страница 5: ...ification see Flow vs Pressure Loss page 3 Rigid Coupling Connection Provides for complete access to the upper chamber acceleration slots and internal separation barrel 2 piece standard EPDM gasket also available in Nitrile Silicone Fluoroelastomer or White Nitrile Vortube Piping provided by LAKOS Rigid Coupling Access Provides full access to collection chamber area for inspection serving standard...

Страница 6: ...rd Install at both inlet and outlet for proper flow verification see Flow vs Pressure Loss page 3 Inspection Drain Plug 1 2 inch NPT female provides access to upper chamber for inspection of slot area also allows for draining the upper chamber if necessary Rigid Coupling Connection Provides for complete access to the upper chamber acceleration slots and internal separation barrel standard EPDM gas...

Страница 7: ...a rigid coupling Not included with separator available separately Hand Hole Inspection Port Provides access to collection chamber Neoprene gasket Vortube Piping provided by LAKOS Dimensions in 72 78 93 1 2 105 3 4 126 3 8 139 3 4 155 1 2 194 1 2 229 mm 1829 1930 2375 2686 3210 3351 3950 4940 5817 in 16 18 20 22 26 32 36 44 48 mm 406 457 508 559 660 813 914 1118 1219 in 21 21 24 24 30 33 38 51 60 m...

Страница 8: ...ve size ______ Pneumatic Pinch Valve Compressed air shall be provided to actuate this full port valve at appropriate intervals and duration in order to efficiently and regularly purge solids from the separator s collection chamber System shall include a pressure regulator for proper modulation of air pressure Valve liner is natural gum rubber other liner materials available Valve size ______ Pneum...

Отзывы: