Exclusive internal acceleration creates maximum 
performance to achieve maximum protection of 
fluid handling systems from unwanted solids 
(see illustration inside for details).  Its advanced 
& patented design, building upon the performance 
LAKOS is known for, now also removes 50% more of 
the finer solids (< 40 microns), resulting in higher 
aggregate solids removal.  Independently tested.  
Proven superior for today's demanding filtration 
requirements.  For settlable solids only.

Trouble-free operation & advanced 
purging/solids-handling concepts keep 
fluids clean and concentrate separated solids

No screens or filter elements to 
clean or replace; no messy servicing routines

No backwashing; zero fluid loss options

Low & steady pressure loss

Choice of profiles to 
accommodate space/piping limitations

Rigid couplings for fast and easy internal access

Swirlex internal accelerating slots for 
optimum solids-removal performance; 
patented; optional annular transfer ring 
for handling larger solids/fibrous materials

Vortube for enhanced solids 
separation/collection; patented

Grooved inlet/outlet connections 
for easy installation; optional 
flanged connections also available

In-line inlet/outlet configuration for 
simplified piping (low-profile models only)

Unishell construction for easy installation

Optional material construction & ASME code  

High performance liquid-solids separation systems

JPX

Flow range: 
4 - 12,750 U.S. gpm
(1 - 2895 m

3

/hr) per unit

Maximum standard
pressure rating: 
150 psi (10.3 bar)

JPX Series includes 
inlet/outlet pressure 
gauges with petcock valves.

Also available with 
weld-on flanges. See 
page 3 for other details. 

How-it-Works Illustration

Model Specifications

Installation & 

Operating Instructions

Maintenance & Purging

Engineering Specifications

Liquid • Solids Separation Systems

Содержание JPX

Страница 1: ...Rigid couplings for fast and easy internal access Swirlex internal accelerating slots for optimum solids removal performance patented optional annular transfer ring for handling larger solids fibrous materials Vortube for enhanced solids separation collection patented Grooved inlet outlet connections for easy installation optional flanged connections also available In line inlet outlet configurati...

Страница 2: ...ge valve for servicing Grooved end connections at inlet outlet for fast secure easy installation Optional ANSI or DIN flanges also available Pressure gauges with petcock valves included as standard to monitor proper flow range see Flow vs Pressure Loss page 3 Outlet Inlet Internal Swirlex tangential slots accelerate flow to maximize separation of solids with reduced pressure loss Particles are sep...

Страница 3: ...terials available consult factory Paint coating Acrylic urethane spray on royal blue 1 1 1 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 Specifications Flow Range U S gpm m3 hr gal liters lbs kg kg lbs Model Weight Weight with Water Collection Chamber Capacity Inlet Outlet Grooved Coupling 1 1 2 1 1 2 1 1 2 1 1 2 2 2 3 3 JPX 0004 JPX 0010 JPX 0016 JPX 0028 JPX 0038 JPX 0060 JPX 0085 JPX 0130 JPX 0200 JPX 02...

Страница 4: ...ressure of at least 5 psi 3 bar Winterizing is important if the LAKOS Separator is to remain idle in freezing temperatures Drain liquid as necessary to avoid expansion of water to ice and related damages Maintenance Purging Installation Instructions 1 LAKOS JPX Separators must be purged regularly to remove the separated solids from the temporary collection chamber 2 All purge hardware should be in...

Страница 5: ...ification see Flow vs Pressure Loss page 3 Rigid Coupling Connection Provides for complete access to the upper chamber acceleration slots and internal separation barrel 2 piece standard EPDM gasket also available in Nitrile Silicone Fluoroelastomer or White Nitrile Vortube Piping provided by LAKOS Rigid Coupling Access Provides full access to collection chamber area for inspection serving standard...

Страница 6: ...rd Install at both inlet and outlet for proper flow verification see Flow vs Pressure Loss page 3 Inspection Drain Plug 1 2 inch NPT female provides access to upper chamber for inspection of slot area also allows for draining the upper chamber if necessary Rigid Coupling Connection Provides for complete access to the upper chamber acceleration slots and internal separation barrel standard EPDM gas...

Страница 7: ...a rigid coupling Not included with separator available separately Hand Hole Inspection Port Provides access to collection chamber Neoprene gasket Vortube Piping provided by LAKOS Dimensions in 72 78 93 1 2 105 3 4 126 3 8 139 3 4 155 1 2 194 1 2 229 mm 1829 1930 2375 2686 3210 3351 3950 4940 5817 in 16 18 20 22 26 32 36 44 48 mm 406 457 508 559 660 813 914 1118 1219 in 21 21 24 24 30 33 38 51 60 m...

Страница 8: ...ve size ______ Pneumatic Pinch Valve Compressed air shall be provided to actuate this full port valve at appropriate intervals and duration in order to efficiently and regularly purge solids from the separator s collection chamber System shall include a pressure regulator for proper modulation of air pressure Valve liner is natural gum rubber other liner materials available Valve size ______ Pneum...

Отзывы: