DISMANTLING INSTRUCTIONS - All Platform Working Heights
Step 1
The dismantling procedure requires
a minimum of 2 operatives to
complete the task safely.
To start, first remove the aluminium
toeboard assembly.
Step 2
Next, remove the 4 guardrails. To
remove braces or guardrails, first
disconnect each brace at the end
furthest away from the platform trap
door. Then immediately take up the
protected position detailed in the
3T method. Whilst standing through
the trapdoor as per the 3T method,
disconnect the braces completely.
Step 3
Now, working from the platform
below, the upper platform(s) can be
removed.