UNPACKING AND OPERATING INSTRUCTIONS 

In  order  to  operate  your  LakeAir  Air  Cleaner  properly,  it  is  necessary  to  remove  plastic  packing  material  from  the  carbon 
afterfilter inside the unit.  Follow the step–by–step instructions and you will soon be enjoying clean fresh air. 

1.

Remove the two fasteners from the top of the

cabinet using a Phillips head screwdriver.

2.

Lift the cover assembly from the chassis and set

aside.

3.

Remove the carbon afterfilter from behind the

cell.  Take off the protective packing material and
discard.

4.

Replace the carbon after filter, then the cover

assembly, making sure to include both of the fasteners.  NOTE: The fasteners must be in place

 

and secured snugly or the unit 

will not operate. 

Place  your  LakeAir  Air  Cleaner  in  a  convenient  area  in  the  desired  room.      If  you  are  using  the  air  cleaner  for  a  specific 
purpose, such as smoke removal, locate the air cleaner as close as possi-ble to the source.  (Such as near a smoking stand.)  Care 
should be taken to allow at least 4-6” of unobstructed space behind the unit so that it will exhaust freely into the room.  If, 
however, you position the unit so that the airflow is parallel to the nearest wall, you need not allow as much free space.  For 
best  results  the  unit  should  be  elevated  by  placing  it  on  a  table  or  stand.    It  can  also  be  mounted  on  a  wall,  using  our 
convenient wall mount option. 

Plug the line cord into a standard household outlet with 120V AC 60 Hz (230 models require 230 V AC 50 Hz).  Caution 
should be taken to use the unit only on the required voltage, as to do otherwise will void the warranty. 

OPERATING AND MAINTE-NANCE 

INSTRUCTIONS

Position the unit and plug it into the proper line voltage before 
turning it on. 

1.

 

To turn unit on, locate the three-position

 

rocker switch 

on top of the unit.  Depress the
button to activate the unit on the desired speed;

 

High, Low, 

or 

Off

 (center, flat position).  Under

 

normal conditions, the 

Low

 

position is adequate

 

to keep an average size room clean.  With 

exces-sive amounts of dust, smoke, or other pollutants

 

present, 

the air cleaner should be operated on

 

high.

2.

 

To shut the unit off, simply push the

 

button to its 

center (flat) position and

 

unplug the unit from the line 

voltage.

NOTE:  It should be noted that occasion-ally a large 
particle will pass through the electronic cell and an 
arcing will occur, resulting in an audible cracking 
sound.  This is normal and will not cause any  damage 
to the unit. 

Содержание excel

Страница 1: ...RK Ventures Inc 1509 Rapids Dr Racine WI 53404 www lakeair com Portable electronic air cleaners Operating and Service Manual Excel 120v Maxum 120v Excel 230 230v Maxum 230 230v ...

Страница 2: ...he motor and fan power supply control switch and all internal wiring are found in the chassis 3 CARBON AFTERFILTER The carbon afterfilter is standard in all Excel and Maxum units and is used as an afterfilter to remove objectionable odors from the cleaned air 4 ELECTRONIC FILTER CELL This is the workhorse of the LakeAir Air Cleaner and performs the major function of the air cleaner by removing the...

Страница 3: ...eing circulated in the air you breathe A LakeAir Electronic Air Cleaner removes these smoke dust dirt and pollen particles with an electrostatic process that works this way 1 The internal circulating fan draws the dirty air into the system where it first must pass through the outer grille 2 The air then passes into the ELECTRONIC CELL where it encounters the IONIZING SECTION with its many fine ion...

Страница 4: ...n the unit so that the airflow is parallel to the nearest wall you need not allow as much free space For best results the unit should be elevated by placing it on a table or stand It can also be mounted on a wall using our convenient wall mount option Plug the line cord into a standard household outlet with 120V AC 60 Hz 230 models require 230 V AC 50 Hz Caution should be taken to use the unit onl...

Страница 5: ...can be obtained through your dealer or by calling LakeAir directly 6 It may be necessary if the cell is extremely dirty to repeat the soaking process or to take a small soft brush to the plates of the cell If this is done care should be taken not to damage the plates or the fine ion wires between the widely spaced plates on the ionizer section of the cells After soaking rinse off all traces of the...

Страница 6: ...all volume of air discharged from unit Clean according to Instructions Extremely dirty electronic filter cell Plastic packing still on carbon after filter Remove plastic wrap Unit not effectively cleaning the air Clean according to Instructions Electronic filter dirty Electronic filter is not prop erly installed Check reassemble instructions Continuous arcing or snap ping noise Excessive accumulat...

Страница 7: ...dgrain 10067 Cover Assembly White 10065 Cover Assembly White 20082 Motor 120v 20048 Motor 120v 21182 Motor 230v 21148 Motor 230v 499052 Fan Blade 499086 Grille Black 499087 Grille Grey 495101 Fan Blade 499088 Grille Black 499089 Grille Grey PARTS COMMON TO BOTH UNITS 10012 499049 Cell Contact Bracket 40054 Ion Connector Strap 470004 Ground Screw U Clip 497572A Voltage Doubler 497606 Transformer 12...

Страница 8: ...n addition LakeAir International Inc warrants the power supply module and transformer in the LakeAir Elec tronic Air Cleaner for an additional six 6 years or a total of seven 7 years from the date of purchase to the original purchaser LakeAir s liability is to be limited to repair ing or replacing such products during the warranty period at its option providing the product is sent prepaid to LakeA...

Отзывы: