470004 

40136 

40137 

20082 (120v) 
21182 (230v) 

 or 

20048 (120v) 

495101 

 or 

499052 

497576 

497612/497613 

10064/10065 

 or 

10067/10066 

499086/499087 

      or 

499088/499089 

10072 (120v) 
10172 (230v) 

470067 

10012 & 499049 

499005 

 or 

499027 

40054 

10011 

 or 

10068 

EXCEL PARTS 

MAXUM PARTS 

Part# 

Description 

Part# 

Description 

10068 

Electronic Filter Cell 

10011 

Electronic Filter Cell 

499027 

Carbon Afterfilter 

499005 

Carbon Afterfilter 

10066 

Cover Assembly-Woodgrain 

10064 

Cover Assembly-Woodgrain 

10067 

Cover Assembly-White 

10065 

Cover Assembly-White 

20082 

Motor 120v 

20048 

Motor, 120v 

21182 

Motor, 230v 

21148 

Motor, 230v 

499052 Fan Blade 499086 
Grille, Black 499087 Grille, 
Grey 

495101 Fan Blade 499088 
Grille, Black 499089 Grille, 
Grey 

PARTS COMMON TO BOTH UNITS 

10012&499049 Cell Contact Bracket 40054 Ion 
Connector Strap 470004 Ground Screw U-Clip 
497572A Voltage Doubler 
497606 Transformer 120v 
497607 Transformer 230v 

40136 Ion Wires w/S-Hooks and Springs (6) 40137 Ceramic 
Insulators w/Screws (4/8) 470067 High Voltage Wire Jiffy Clip 
Fastener 470033 Black cover Fastener  
495159 White Cover Fastener 
497613 Grey Rocker Switch 
497612 Black Rocker Switch  

Содержание excel

Страница 1: ...RK Ventures Inc 1509 Rapids Dr Racine WI 53404 www lakeair com Portable electronic air cleaners Operating and Service Manual Excel 120v Maxum 120v Excel 230 230v Maxum 230 230v ...

Страница 2: ...he motor and fan power supply control switch and all internal wiring are found in the chassis 3 CARBON AFTERFILTER The carbon afterfilter is standard in all Excel and Maxum units and is used as an afterfilter to remove objectionable odors from the cleaned air 4 ELECTRONIC FILTER CELL This is the workhorse of the LakeAir Air Cleaner and performs the major function of the air cleaner by removing the...

Страница 3: ...eing circulated in the air you breathe A LakeAir Electronic Air Cleaner removes these smoke dust dirt and pollen particles with an electrostatic process that works this way 1 The internal circulating fan draws the dirty air into the system where it first must pass through the outer grille 2 The air then passes into the ELECTRONIC CELL where it encounters the IONIZING SECTION with its many fine ion...

Страница 4: ...n the unit so that the airflow is parallel to the nearest wall you need not allow as much free space For best results the unit should be elevated by placing it on a table or stand It can also be mounted on a wall using our convenient wall mount option Plug the line cord into a standard household outlet with 120V AC 60 Hz 230 models require 230 V AC 50 Hz Caution should be taken to use the unit onl...

Страница 5: ...can be obtained through your dealer or by calling LakeAir directly 6 It may be necessary if the cell is extremely dirty to repeat the soaking process or to take a small soft brush to the plates of the cell If this is done care should be taken not to damage the plates or the fine ion wires between the widely spaced plates on the ionizer section of the cells After soaking rinse off all traces of the...

Страница 6: ...all volume of air discharged from unit Clean according to Instructions Extremely dirty electronic filter cell Plastic packing still on carbon after filter Remove plastic wrap Unit not effectively cleaning the air Clean according to Instructions Electronic filter dirty Electronic filter is not prop erly installed Check reassemble instructions Continuous arcing or snap ping noise Excessive accumulat...

Страница 7: ...dgrain 10067 Cover Assembly White 10065 Cover Assembly White 20082 Motor 120v 20048 Motor 120v 21182 Motor 230v 21148 Motor 230v 499052 Fan Blade 499086 Grille Black 499087 Grille Grey 495101 Fan Blade 499088 Grille Black 499089 Grille Grey PARTS COMMON TO BOTH UNITS 10012 499049 Cell Contact Bracket 40054 Ion Connector Strap 470004 Ground Screw U Clip 497572A Voltage Doubler 497606 Transformer 12...

Страница 8: ...n addition LakeAir International Inc warrants the power supply module and transformer in the LakeAir Elec tronic Air Cleaner for an additional six 6 years or a total of seven 7 years from the date of purchase to the original purchaser LakeAir s liability is to be limited to repair ing or replacing such products during the warranty period at its option providing the product is sent prepaid to LakeA...