Command Pro Engineered Systems
User Manual
30
142134
6.7.3
22R08A Installation Testing
Before putting the system into service, perform the following testing procedure:
1.
Apply the appropriate power to the receiver (12-24 VDC or 120 VAC).
2.
Verify that the POWER (DS3) LED turns ‘ON’. Refer to
Figure 15
.
3.
Turn on the transmitter.
4.
Verify that the Signal (DS1) LED flashes.
5.
Verify that pressing any function switch on the transmitter lights the corresponding relay on the
receiver and the Relay (DS2) LED.
Review all of the steps above to ensure the accuracy of the wiring.
Figure 15: 22R08A LED Status Indicators
Содержание Command Pro SAFE-T-RANGE
Страница 19: ...Command Pro Engineered Systems User Manual 19 142134 Figure 6 21R14A Receiver ...
Страница 20: ...Command Pro Engineered Systems User Manual 20 142134 Figure 7 Typical 21R14A Power Control Wiring ...
Страница 23: ...Command Pro Engineered Systems User Manual 23 142134 Figure 9 Typical 21R22 Power Control Wiring ...
Страница 31: ...Command Pro Engineered Systems User Manual 31 142134 Figure 16 22R08A Series Receiver Relay Output Connections ...