Figure 15: Verify COM port 

 

To configure PC settings, follow these steps: 

1.  Open the Configuration and Test Utility (CU). 
2.  Click on the 

PC Settings

 tab to configure the following PC settings to enable you to communicate with the ConnexLink 

Unit as shown in Figure 4. 

a.  If Select the product from the Product 

drop-down menu.

 

b.  Select the COM Port verified in 

Device Manager from the drop-down 
menu. If none are listed, click the 
[Find Ports] button 

c. 

Default baud rate of 57600 should be 
selected, but if it is known that the 
unit has been configured to a 
different baud rate, select it here. 

Note:

 If connecting to a previously 

configured radio, set baud rate 
to what is configured on the 
radio. 

d.  Set Parity to None (recommended) 
e.  Set Handshaking to the following 

– 

depending on the interface: 

RS232

: Hardware (recommended)  

RS485

: None 

f. 

Set Data Bits to 8 

g.  Set Stop Bits to 1 

Figure 16: PC Settings

 

Содержание CL4490

Страница 1: ...SA 19HS RS485 to USB example ULinx RS485 to USB Model 485USBTB 2W RS485 to RS232 combined with RS232 to USB adapter example B B Electronics Model 485SD9TB PC Operating Windows XP or newer Laird Config...

Страница 2: ...ong Kong 852 2762 4823 Figure 1 Extract All 2 Install the extracted files Be sure to run the installation software as administrator right click on Setup exe application and select Run as administrator...

Страница 3: ...e files will be installed into Click the button to install Figure 4 Begin installation c Click Continue Figure 5 Continue d Reboot your system to complete the installation Figure 6 Reboot Note Be sure...

Страница 4: ...ese settings override any EEPROM configurations and so must be configured correctly to operate as expected with the settings that will be configured on the radio with the Laird Configuration and Test...

Страница 5: ...pment that the radio will be interfacing with Note RS232 Forced 9600 is for recovery mode ONLY It should never be used in an application If a baud rate of 9600 is required it should be configured usin...

Страница 6: ...1628 858 940 Hong Kong 852 2762 4823 Figure 11 Connected with serial cable c CL4490 1000 485 can be connected using an RS485 to USB adapter or combination RS485 to RS232 RS232 to USB adapter as shown...

Страница 7: ...ange of paired server Server radio Green Power LED Red Link LED Figure 14 Client LEDs not paired Server LEDs or client in range of paired server To verify the COM port in the Device Manager follow the...

Страница 8: ...a If Select the product from the Product drop down menu b Select the COM Port verified in Device Manager from the drop down menu If none are listed click the Find Ports button c Default baud rate of 5...

Страница 9: ...ad Radio Figure 18 Read Successful Note If you receive a message that the read was not successful or Unable to enter command mode verify the Baud setting on PC settings tab You can use AutoBaud mode w...

Страница 10: ...er to Client b Set RF Channel 16 by default must be set the same on server c Set System ID 1 by default must be set the same on server d Ensure Auto Destination is enabled e Ensure Broadcast Mode is d...

Страница 11: ...follow these steps 1 Return to PC Settings Tab 2 Click Close Port Figure 22 Close port 3 Disconnect from the client and connect to the second radio as per sections 6 7 above 4 Configure the server wit...

Страница 12: ...23 Figure 17 Server settings Note The RF Channel and System ID must be set the same on the Server and the Client for them to Pair 5 Click OK when prompted The CU returns Write Successful message when...

Страница 13: ...io again to confirm communications and that changes were written correctly to the radio To set the test configurations follow these steps 1 Ensure the power supply is connected to both the client and...

Страница 14: ...o the first radio client and make sure that it is at least five feet away from the second unit server 3 With the second unit still connected to the Configuration Utility via the PC click on Range Test...

Страница 15: ...To configure a P2MP system follow steps 1 8 to configure the first client and server The Server MUST be configured in Broadcast mode for P2MP systems Then repeat step 7 for as many clients as will be...

Отзывы: