By default, single units are configured as a client. Each CL4490 system requires one unit to be configured as a server.
1. Configure the client with the following basic settings:
a. Set client/server to
Client
b. Set RF Channel
– 16 by default (
must
be set the same on server)
c.
Set System ID
– 1 by default (
must
be set the same on server)
d. Ensure
Auto-Destination
is enabled
e. Ensure
Broadcast Mode
is disabled
f.
Interface Baud
– should be set to host device requirements (for demo we set to 9600)
g. All other settings
– Leave as default
Figure 19: Client configuration
2. Click
Write Radio
to save the configuration changes to the radio.
3. Click
OK
when prompted. The CU will return
Write Successful
message when complete. Click
OK
.
Figure 20: Write successful