- 9 -
1 • GENERAL WARNINGS
• The room
where the oven is installed
must be well-ventilated!
•
The oven power supply must have omnipolar mains switch with a
minimum opening distance between the contacts of at least 3 mm
per pole.
•
The device has been designed for permanent connection to the
water mains.
•
The mains water pressure must be between 200 and 500 kPa.
• The flexible water intake tube must be supplied by the installer
and must conform to standard IEC 61770. Do not reuse pre-
existing or used connection tubes.
•
The oven must be part of an equipotential bonding system. This
connection is made by attaching a conductor with a nominal
section of up to 10 mm
2
to the specific terminal, located on the
rear of the oven, marked with the international symbol IEC60417 –
5021.
The connection is made between all the adjacent devices in the
room and the dispersion system in the building.
• This device is for use up to an altitude of 2000m above sea level.
For installations at altitudes over 2000m above sea level., please
contact an authorised technical service centre.
90037450rev00