Instruction LTC 11 Laing Innotech GmbH + Co. KG Althuette Germany
- 27 -
As the controller will be supplied with set limits, changes can only be made
when the present value is deleted as described below, after that a new limit
can be set.
•
Move the table top by use of the arrow keys to the maximum or minimum
desired height
•
Press the left arrow key 4 times quickly one after another
•
Reaching the program mode will be confirmed by a sound
•
Press the right arrow key shortly six times
•
Reaching the limit adjustment menu will be confirmed by six sounds
•
Then
o
If the top limit should be defined press the “up” key, the table must
be at the desired top position
o
If the bottom limit should be defined press the “down” key, the table
must be at the desired bottom position
•
The successful adjustment of the new upper limit will be confirmed by two
sounds
Attention: The top and lower limits must keep a minimum distance so that
the table can still move after the new limits have been adjusted. This
minimum distance is defined in the parameter set entered into the
controller. Saving a new upper or lower limit is not possible if the minimum
distance is not maintained. In this case when pushing the appropriate
arrow key to save the new limit the following short beeps can be heard,
indicating that the new limit was not saved. In this case the distance
between the upper and lower limit must be increased and the process must
be repeated.
Delete stroke limits
•
Make sure, no user height limit is defined! If a user height limit is
defined, see “delete user height limits” and delete the limits set
before you proceed!
•
Move the table top to the upper or lower limit by use of the arrow keys
(press the key until the table stops as the adjusted limit is reached)
•
Press the left arrow key 4 times quickly one after another
•
Reaching the program mode will be confirmed by a sound
•
Press the right arrow key shortly six times
•
Reaching the limit adjustment menu will be confirmed by six sounds
•
Then
o
If the table top is at the upper position and the adjustment for the
upper position shall be deleted press the “up” arrow key.
o
If the table top is at the lower position and the adjustment for the
lower position shall be deleted press the “down” arrow key.
•
Successful deletion of the position will be confirmed by a sound