background image

21

Rev. D  1-19-00

P/N 471243

ITEM

DESCRIPTION

QUANT.

PART NUMBER

  1*

Indoor Draft Hood

1

471198

  1A

Outdoor Top

1

471213

  2*

Indoor Top (Cover)

1

471075

  3*

Indoor Stack Adaptor

1

471214

  *

Indoor Draft Hood Kit consisting of items 1, 2,& 3

1

471187

  4

Middle Top

1

471069

  5

Flue Collector

1

471059

  6

Return Header

1

471096

  7

Bolt 3/8 x 16 UNC x 3/4

4

471200

  8

Rubber Seal tube

10

470742

  9

Heat Exchanger Less Heads

1

471093

10

Main Header (Inlet/Outlet)

1

471094

 11

Combustion Chamber

1

N.A.

12

Ignitor Electrode Bracket

1

471058

13

Burner Natural Gas

1

471122

Burner Propane

1

471136

14

Ignitor Electrode

1

471090

15

Gas Valve-Nat. Gas DSI-Robertshaw

1

471088

Gas Valve-Propane DSI-Robertshaw

1

471089

Gas Valve-Nat. Gas Millivolt-Robertshaw

1

471192

Gas Valve-Propane Millivolt-Robertshaw

1

072125

Gas Valve-Nat. Gas Millivolt-SIT

1

471437

Gas Valve-Propane Millivolt-SIT

1

471435

16

Thermostat-Millivolt Models

1

072022

Thermostat (Electronic)-Direct Spark Models

1

471431

17

On/Off Switch spst

1

471128

18

Heat Shield Burner Tray

1

471070

19

Control Panel Assy

1

471078

20

Door Assembly

1

471067

21

Control Bracket

1

471159

22

Ignition Control DSI

1

471091

23

Transformer

1

074033

24

Jacket Assembly

1

N.A.

25

Inspection Panel

1

471071

26

Burner Tray Back Support

1

471169

27

Burner Tray Side Support

2

471166

28

Heat Exchanger Support Brackets

2

471164

29

Hi-Limit Safety Switch

2

071017

30

Flow Valve, assy.

1

471095

31

Pressure Switch

1

471097

32

Baffle Hold Down Bracket

1

471064

33

Flue Baffle

4

471065

**

Items Below Not Shown

**

Washer 3/8 I.D.

4

072169

**

Thermal Cutoff Switch

1

075173

**

Pilot Natural Gas Millivolt

1

471239

**

Pilot Propane Millivolt

1

471238

**

Thermopile Generator

1

071515

**

Quick-flange Kit for 2" slip connection

1

471215

**

Quick-flange II Kit for 1½" thd. connection

1

471083

**

Kit Wiring Laguna 100K Millivolt

1

471201

**

Kit Wiring Laguna 100K DSI

1

471202

**

Knob

1

470184

**

Knob Stopper

1

470414

**

Presslite Piezo Ignitor Assy-Millivolt

1

075459

**

Valve Drain 1/4 npt

1

072136

**

Hi-Tension Ignition Cable

1

471092

**

Rubber bushing, 2" i.d.

2

070544

PARTS LIST

Содержание 100K

Страница 1: ...injury or death Installation and service must be performed by a qualified installer service agency or the gas supplier To Consumer Retain For Future Reference Laguna 100K ABOVE GROUND POOL SPA HEATER...

Страница 2: ...cal Balance 11 Pool and Spa Water 11 Installation Instructions 12 Specifications 12 Outdoor Installation 12 Indoor Installation 12 Plumbing Connections 13 ManualBypass 13 Valves 13 Pressure Switch 13...

Страница 3: ...reliable in worldwide usage Heatexchangerconstructedofpremiumnon corrodingmaterialsincludingbronzeheadersstandard The controls have been designed to be very easy to troubleshoot and very easy to acces...

Страница 4: ...ninthismanualappliestotheLaguna100Knaturalgasandpropane DSIandmillivoltstandingpilotheatermodels It is very important the owner installer read and understand the section covering installation and reco...

Страница 5: ...et the thermostat to lowest setting fully counterclockwise 3 Turn off electric power to the heater 4 This heater is equipped with an ignition device which automatically lights the main burner Do not t...

Страница 6: ...formed 3 Remove control access door 4 Turn gas control lever horizontally to OFF Do not force 5 Replace control access door Operation contd MILLIVOLT LIGHTING OPERATION NATURAL GAS PROPANE FOR YOUR SA...

Страница 7: ...d the demand for heat ends the main valve is de energized immediately Screw A Operation contd Knob Stopper Figure 5 OPERATING CONTROLS DIRECT SPARK ELECTRONIC AND MILLIVOLT MODELS For convenience and...

Страница 8: ...e is considerable air trapped in the gas supply line unsuccessful ignition indicates other problems with the ignition system such as an unclean ignition electrode impeding flame sensing 3 If the therm...

Страница 9: ...horted Ign electrode B Open HV Ign cable C Miswired D Bad DSI control 4 Spark on no valve A Valve coil open B Open valve wire C Bad control also check voltage between V1 V2 5 Flame okay during A Bad e...

Страница 10: ...weekends it is not necessary to leave the thermostat set at 78 F Lower the temperature to a range that can be achieved easily in one day Generally this would be 10 F to 15 F if pool heater is sized pr...

Страница 11: ...al Weak Lye solution have a pH of 13 14 RULE 7 4 to 7 6 is a desirable pH range It is essen tial to maintain correct pH see Table 2 Maintenance contd If pH becomes too high over alkaline it has these...

Страница 12: ...on a level surface consisting entirely of or a combination of noncombustible materials such as steel iron brick tile concrete slate or plaster Do not install on carpeting The heater must be installed...

Страница 13: ...eater has the unique capability of direct schedule 40 or 80 CPVC ABS PVC plumbing connections Either a Quick Flange or Quick Flange II depending on model ordered has been included with the Laguna 100K...

Страница 14: ...e II a Or first thread a 1 in npt x 1 in slip CPVC ABS male adaptor not supplied to the Quick Flange II and after preparing the joint by sanding with a medium grit sandpaper glue the pipe to the adapt...

Страница 15: ...d on the same meter The gas line from the meter will usually be of a larger size than the gas valve supplied with the heater Therefore a reduction of the connecting gas pipe will be necessary Make thi...

Страница 16: ...ny fences walls or shrubs at any side or back nor closer than 18 inches at the plumbing side A minimum clearance of 24 inches must be maintained at front of heater see Figure 14 IMPORTANT When locatin...

Страница 17: ...xchanger or water connections will not result in damage to the area adjacent to the heater or the structure When such locations cannot be avoided it is recommended that a suitable drain pan with adequ...

Страница 18: ...plug must be plugged into an outdoor rated watertight GFCI protected receptacle rated for 10 amps minimum a constant power source is recommended If the heater must be hard wired you must remove the c...

Страница 19: ...OUND WIRE GREEN HERE GROUND SCREW WITH PAINT CUTTING WASHER EXTERNAL BOND LUG CHASSIS SHEET METAL V1 TH V2 GRD N H GRN WHT BLUE WHT ORN ORN GRN WHT WHT WHT WHT WHT WHT ELECTRONIC 1 2 3 4 TRANSFORMER W...

Страница 20: ...ace wires Defective pressure switch Replace Switch Defective gas controls Call serviceman On Off switch in OFF position Turn switch to ON Heater Short Cycling Rapid On and Off Operation Insufficient w...

Страница 21: ...ronic Direct Spark Models 1 471431 17 On Off Switch spst 1 471128 18 Heat Shield Burner Tray 1 471070 19 Control Panel Assy 1 471078 20 DoorAssembly 1 471067 21 Control Bracket 1 471159 22 Ignition Co...

Страница 22: ...22 P N 471243 Rev D 1 19 00 EXPLODED VIEW 33 14 13a...

Страница 23: ...ject to accident negligence alteration abuse misapplication or misuse The above warranty applies only if the heater is installed and operated in complete compliance with the installation and operation...

Страница 24: ...24 P N 471243 Rev D 1 19 00 Laguna Pools and Spa Products P O Box8085 Moorpark CA93020 805 523 2400...