background image

3

Rev. D  1-19-00

P/N 471243

Introduction

Laguna 100K

ABOVE GROUND POOL AND SPA HEATERS

Congratulations on your purchase of a Laguna 100K high performance heating system. Proper installation and
service of your new heating system and correct chemical maintenance of the water will ensure years of enjoyment.
The Laguna 100K is a compact, lightweight and efficient gas fired high performance above ground pool and spa
heater that can be connected to schedule 40 CPVC or ABS pipe and has a built-in top. The heater features include
the following features.

• Reliable direct-spark ignition (DSI) system available in propane or natural gas versions.
• Millivolt standing pilot versions in propane and natural gas, when no convenient line power is present.
• Fuel gas input of 100,000 btu/hr with thermal efficiency in excess of 82%.
• Quiet and dependable operation from packaged burner system proven reliable in worldwide usage.
• Heat exchanger constructed of premium non-corroding materials including bronze headers standard.
• The controls have been designed to be very easy to troubleshoot and very easy to access and replace in the

rare event of a malfunction-making the Laguna 100K user friendly.

IMPORTANCE NOTICES FOR THE INSTALLER AND OPERATOR.

The manufacturer’s warranty may be void if, for any reason, the heater is improperly installed and /or operated.
Be sure to follow the instructions set forth in this manual.
These heaters are designed for the heating of swimming pools and spas, and should never be employed for use as
space heating boilers, general purpose water heaters, or for the heating of salt water.

CODES

The installation must conform with local codes or in the absence of local codes with the latest National Fuel Gas
Code, ANSI Z223.1, and the latest edition of the National Electrical Code, NFPA 70.
Installation in Canada to be made in accordance with the latest CAN/CGA-B149.1 or .2 and CSA C22.1
Canadian Electric Code, part 1.

Содержание 100K

Страница 1: ...injury or death Installation and service must be performed by a qualified installer service agency or the gas supplier To Consumer Retain For Future Reference Laguna 100K ABOVE GROUND POOL SPA HEATER...

Страница 2: ...cal Balance 11 Pool and Spa Water 11 Installation Instructions 12 Specifications 12 Outdoor Installation 12 Indoor Installation 12 Plumbing Connections 13 ManualBypass 13 Valves 13 Pressure Switch 13...

Страница 3: ...reliable in worldwide usage Heatexchangerconstructedofpremiumnon corrodingmaterialsincludingbronzeheadersstandard The controls have been designed to be very easy to troubleshoot and very easy to acces...

Страница 4: ...ninthismanualappliestotheLaguna100Knaturalgasandpropane DSIandmillivoltstandingpilotheatermodels It is very important the owner installer read and understand the section covering installation and reco...

Страница 5: ...et the thermostat to lowest setting fully counterclockwise 3 Turn off electric power to the heater 4 This heater is equipped with an ignition device which automatically lights the main burner Do not t...

Страница 6: ...formed 3 Remove control access door 4 Turn gas control lever horizontally to OFF Do not force 5 Replace control access door Operation contd MILLIVOLT LIGHTING OPERATION NATURAL GAS PROPANE FOR YOUR SA...

Страница 7: ...d the demand for heat ends the main valve is de energized immediately Screw A Operation contd Knob Stopper Figure 5 OPERATING CONTROLS DIRECT SPARK ELECTRONIC AND MILLIVOLT MODELS For convenience and...

Страница 8: ...e is considerable air trapped in the gas supply line unsuccessful ignition indicates other problems with the ignition system such as an unclean ignition electrode impeding flame sensing 3 If the therm...

Страница 9: ...horted Ign electrode B Open HV Ign cable C Miswired D Bad DSI control 4 Spark on no valve A Valve coil open B Open valve wire C Bad control also check voltage between V1 V2 5 Flame okay during A Bad e...

Страница 10: ...weekends it is not necessary to leave the thermostat set at 78 F Lower the temperature to a range that can be achieved easily in one day Generally this would be 10 F to 15 F if pool heater is sized pr...

Страница 11: ...al Weak Lye solution have a pH of 13 14 RULE 7 4 to 7 6 is a desirable pH range It is essen tial to maintain correct pH see Table 2 Maintenance contd If pH becomes too high over alkaline it has these...

Страница 12: ...on a level surface consisting entirely of or a combination of noncombustible materials such as steel iron brick tile concrete slate or plaster Do not install on carpeting The heater must be installed...

Страница 13: ...eater has the unique capability of direct schedule 40 or 80 CPVC ABS PVC plumbing connections Either a Quick Flange or Quick Flange II depending on model ordered has been included with the Laguna 100K...

Страница 14: ...e II a Or first thread a 1 in npt x 1 in slip CPVC ABS male adaptor not supplied to the Quick Flange II and after preparing the joint by sanding with a medium grit sandpaper glue the pipe to the adapt...

Страница 15: ...d on the same meter The gas line from the meter will usually be of a larger size than the gas valve supplied with the heater Therefore a reduction of the connecting gas pipe will be necessary Make thi...

Страница 16: ...ny fences walls or shrubs at any side or back nor closer than 18 inches at the plumbing side A minimum clearance of 24 inches must be maintained at front of heater see Figure 14 IMPORTANT When locatin...

Страница 17: ...xchanger or water connections will not result in damage to the area adjacent to the heater or the structure When such locations cannot be avoided it is recommended that a suitable drain pan with adequ...

Страница 18: ...plug must be plugged into an outdoor rated watertight GFCI protected receptacle rated for 10 amps minimum a constant power source is recommended If the heater must be hard wired you must remove the c...

Страница 19: ...OUND WIRE GREEN HERE GROUND SCREW WITH PAINT CUTTING WASHER EXTERNAL BOND LUG CHASSIS SHEET METAL V1 TH V2 GRD N H GRN WHT BLUE WHT ORN ORN GRN WHT WHT WHT WHT WHT WHT ELECTRONIC 1 2 3 4 TRANSFORMER W...

Страница 20: ...ace wires Defective pressure switch Replace Switch Defective gas controls Call serviceman On Off switch in OFF position Turn switch to ON Heater Short Cycling Rapid On and Off Operation Insufficient w...

Страница 21: ...ronic Direct Spark Models 1 471431 17 On Off Switch spst 1 471128 18 Heat Shield Burner Tray 1 471070 19 Control Panel Assy 1 471078 20 DoorAssembly 1 471067 21 Control Bracket 1 471159 22 Ignition Co...

Страница 22: ...22 P N 471243 Rev D 1 19 00 EXPLODED VIEW 33 14 13a...

Страница 23: ...ject to accident negligence alteration abuse misapplication or misuse The above warranty applies only if the heater is installed and operated in complete compliance with the installation and operation...

Страница 24: ...24 P N 471243 Rev D 1 19 00 Laguna Pools and Spa Products P O Box8085 Moorpark CA93020 805 523 2400...

Отзывы: