PL1220 Laser, MLC122040
Machine Maps
© 03/2018, Laguna Tools, Inc.
9
2.2
External Map
KEY
A.
Frame
B.
Lid with Viewing Window
C.
Removable Bottom
D.
Removable Side Panel
E.
Emergency Stop
F.
Power Switch
G.
Controller & Display
H.
4” Fume Port
I.
PC-USB Connection Input
J.
USB Flash Drive Input
K.
Ethernet Connection
Input
L.
Circuit Breaker
M.
Power Connection Input
N.
Distilled Water Inlet
O.
Distilled Water Outlet
P.
Compressed Air Inlet
Q.
Standby Alarm Input
R.
Chiller Alarm Input
S.
Removable Rear Panel
Also See:
Connection Diagram
Appendix 6: Exploded Parts
DESCRIPTION AND PURPOSE
A.
Frame – Also called the enclosure, the frame encloses the laser
beam and all internal components.
B.
Lid with Viewing Window – The lid is hinged on two dampening
rods that hold the lid in place when open. It is equipped with
sensors to detect when the laser is running.
The laser beam will not fire with the lid in the open position.
C.
Removable Bottom – The bottom can be placed into the laser
Chassis or removed for cleaning and maintenance.
D.
Removable Side Panel – Used to enclose the laser beam.
Can be removed to service the machine.
E.
Emergency Stop – To be used to stop the machine at any point
in time during operation. The switch must then be rotated and
unlocked prior to restarting the machine.
F.
Power Switch – Used to turn the machine on and off.
G.
Controller & Display – The controller used has many functions
and features and works in collaboration with the software
package RDWorks. See the Controls and Software Machine
Map sections to further explore them and get started.
H.
4” Fume Port – The fume port is to be used with 4” metal
ductwork and a blower or fume extractor to vent the machine.
I.
PC-USB Connection Input – Used to connect the machine to
a PC or other device to transfer work files to the machine.
A PC can also be connected to the machine to transfer machine
data to the RDWorks Software on the PC.
J.
USB Flash Drive Input – Used to transfer job files via USB flash
drive (AKA memory card).
K.
Ethernet Connection Input – Used to connect the machine to
a network to transfer work files.
L.
Circuit Breaker – Used to protect the lasers electrical
components and operator from electrical malfunctions.
The breaker included with the machine is a 2P C10 10 Amp
breaker.
M.
Power Connection Input – To be used with an IEC320-C13
to NEMA 5-15P power cord to give power to the machine.
The same cable is used to connect the chiller unit to a power
source.
N.
Distilled Water Input – To be used with the supplied ¼” silicon
water hose to supply water from the chiller output connection to
the laser tube. The laser will not fire without water circulating
through the laser tube.
O.
Distilled Water Output – To be used with a ¼” silicone water
hose to take water from the laser back to the chiller input
connection.
P.
Compressed Air inlet – Used with an air hose and included air
pump to supply air to the workpiece through the laser head.
The air supply keeps the path for the laser beam open and free
of debris.
Q.
Standby Alarm Input – This is an optional plug that is not
used with the PL1220 Machine.
R.
Chiller Alarm Input – To be used to connect the chiller alarm
circuitry and the laser tube. The alarm will sound when water
cannot be supplied to the laser tube and the laser will not fire.
S.
Removable Rear Panel – Houses electrical components, can
be removed to service the machine.
A
B
C
D
I
E
F
G
H
J K
L M
N
O
P
Q
U