First Start Up:
-
After filling the reservoir through the fill cap, it is necessary to prime the pump. Check that all
the valves and distributors are in the rest position, at the time of starting do not operate any
movement.
-
To prime, jog the start button (electric motor). When the unit emits a dull sound with no jumps
and the sound of the pump is constant. An uneven “tinny” noise indicates there is air in the
pump.
-
The oil in the reservoir may fall on start up. Therefore, it is necessary to top off the level of oil
bringing it up to the correct height, by checking the level gauge. The level should be about
halfway up the stick.
Joystick Operation:
-
Pulling -
the lever toward the operator (Pos. 2) the piston rod lowers.
-
Pushing -
the lever from the opposite side to the operator (Pos. 3) the piston rod will go up.
-
Releasing -