Note 1

:

 

 

Note 2:

For maximum battery life, turn the MMT OFF when not in use.  While battery 
saver mode greatly reduces the strain on the battery, the battery does still lose a 
small amount of power.

Battery saver mode will only activate from the main menu screen.  If the MMT is 
left in a menu or sub-menu, the battery saver mode will not activate.

Battery Saver Mode:

The MMT has a built-in battery saver mode to power down the circuitry when the device is 
not in use.  This reduces the wear on the battery and prolongs battery life.  The Battery Saver 
Mode is initiated after two minutes of inactivity on the MMT.  When in battery saver mode, the 
LCD and measurement circuitry are powered down.  This will result in the screen going blank.  

To wake up from Battery Saver Mode:

1. Press one of these four buttons: RESET, MENU, ENTER or SCROLL

2. Pressing the RANGE button does not wake up the MMT

Low Battery Detection:

The MMT is equipped with circuitry 
to detect when the battery is low on 
power.  

Low Battery Detection guidelines:

1.  The MMT uses two methods to indicate a low battery condition. 
2.  The first is a battery icon displayed in the center of the Main Measurement Screen.  
 

(See Main Measurement Screen on page 7.)

3.  The second is an audible beep with an error message that requires a button response.  
 

(See errors and warning messages on page 16.)

4.  The low battery error message is given every time the MMT is turned on or is reactivated 

after being in Battery Saver Mode.

5.  The battery will run for about 10 hours after a low battery condition is detected.
6.  Stored test data is NOT affected by a low or dead battery.  Removing the battery will not 

result in any loss of stored data (current test data that is not stored will be lost).

7.  Accuracy of the force or time measurements are not affected by a low battery condition.

For directions on changing the battery, 

see the Battery Change description on page 15.

Содержание 01163

Страница 1: ...P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com 2003 by Lafayette Instrument Company Inc All Rights R...

Страница 2: ...oll LB KG Button 6 Enter Store Button 6 Menu Button 6 Main Measurement Screen 7 Menu Descriptions 8 Main Menu 8 Show Data Menu 8 Function Descriptions 9 Download 9 Show Data 9 Version Identi er 10 Del...

Страница 3: ...bject The Lafayette MMT readily lends itself to large pre participation screenings or eld examinations where bulky more expensive systems do not The microprocessor control allows for storage of calibr...

Страница 4: ...l test time Data storage for up to 52 tests in on board memory peak force and time to reach peak force Manual or automatic storage of data Dual measurement range 0 300lbs 136 1kg or 0 50lbs 22 6kg Sel...

Страница 5: ...The unit is simply placed between the examiner s hand and the limb being tested The examiner s downward force is transmitted to the limb through the MMT unit The MMT is designed for one hand operatio...

Страница 6: ...esetting Changing the range causes the MMT to automatically reset and clear all time and force values Scroll LB KG Button The LB KG button has dual functionality depending on which screen is accessed...

Страница 7: ...e is displayed on the lower right of the Main Measurement Screen This value shows the total time that force has been applied After a test has ended this value shows the total length of the test in sec...

Страница 8: ...ction Descriptions for details on each option Download The Download function allows data to be transferred to a computer for permanent storage The download is accomplished via infrared connection to a...

Страница 9: ...n can not be established an error is given along with two audible beeps An option menu is then given which allows 1 a reattempt of communication or 2 canceling the operation The download device receiv...

Страница 10: ...U button 2 Press the SCROLL button one 1 time to move the cursor to SHOW DATA 3 Press ENTER to turn the display to SHOW DATA menu 4 Press the SCROLL button two 2 times to move the cursor to CLEAR ALL...

Страница 11: ...ove the cursor to BEEP 3 Press ENTER to turn on BEEP 4 Press the SCROLL button four 4 times to move the cursor to END 5 Press ENTER to exit the menu After the test time has ended no more data is measu...

Страница 12: ...nwanted data may inadvertently be stored The MMT will store all tests including test trials and force readings from inadvertent pressing of the load cell If a test requires that only a select number o...

Страница 13: ...limit Excessive force may cause permanent damage to the MMT or alter the calibration Caution Since the RESET button re zeros the MMT force should not be applied while the RESET button is pressed Reset...

Страница 14: ...m Battery Saver Mode 1 Press one of these four buttons RESET MENU ENTER or SCROLL 2 Pressing the RANGE button does not wake up the MMT Low Battery Detection The MMT is equipped with circuitry to detec...

Страница 15: ...3Photo CR17345 DL123ABU Panasonic CR123A Kodak K123L Acceptable Replacement Batteries Battery Change The battery of the MMT is accessed through a removable door in the face of the device The door is s...

Страница 16: ...ired to change the stirrups In the event that a stirrup breaks or becomes soiled new stirrups may be ordered through Lafayette Instrument Company Error and Message Screen Summary The MMT has special m...

Страница 17: ...FULL error is accompanied by two audible beeps The user must press the ENTER button to acknowledge and clear the warning They must then either discontinue storage by disabling the AUTO STORE feature o...

Страница 18: ...ngth because it takes into account the length of the muscle being tested The Lafayette Manual Muscle Test System MMT can be used to obtain torque values through a series of basic calculations Torque i...

Страница 19: ...Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Model 01163 User Instructions 19 Notes...

Страница 20: ...PO Box The items should be packed well insured for full value and returned along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative a...

Отзывы: