Lafayette 01163 Скачать руководство пользователя страница 11

3700 Sagamore Parkway North . PO Box 5729 . Lafayette, IN 47903 USA . Ph: 765-423-1505                                   Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail:[email protected]

3700 Sagamore Parkway North . PO Box 5729 . Lafayette, IN 47903 USA . Ph: 765-423-1505                                   Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail:[email protected]

Model 01163     User Instructions

11

Beep:

The Beep function activates an 
audible tone that indicates when a 
preset test length has expired. With 
the beep enabled, a single beep is 
sounded at the start of the test.  The 
MMT automatically detects when 
force is applied, so no buttons have 
to be pressed to begin the test. After 
the preset test time is reached, 4 
successive beeps are sounded to 
indicate that the test is over.

To activate the Beep function:

1.  Enter the Main Menu by pressing the MENU button.
2.  Press the SCROLL button two (2) times to move the cursor to BEEP.
3.  Press ENTER to turn on BEEP
4.  Press the SCROLL button four (4) times to move the cursor to END.
5.  Press ENTER to exit the menu.

After the test time has ended, no more data is measured until RESET is pressed.  A reset will 
automatically occur when a new force is applied. Only values that are measured during the test 
time are used to determine the peak value.

Time:

This setting determines the preset 
test time length for the test.  The 
preset test time can be set from 1 
second to 10 seconds in 1 second 
increments.  This only works when 
the 

Beep 

function is activated.

To set the test time:

1.  Enter the Main Menu by pressing the MENU button.
2.  Press the SCROLL button three (3) times to move the cursor to TIME.
3.  Press ENTER to increment the time.  The time loops back to 1 after 10 is reached.
4.  Press the SCROLL button three (3) times to move the cursor to END.
5.  Press ENTER to exit the menu.

Содержание 01163

Страница 1: ...P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com 2003 by Lafayette Instrument Company Inc All Rights R...

Страница 2: ...oll LB KG Button 6 Enter Store Button 6 Menu Button 6 Main Measurement Screen 7 Menu Descriptions 8 Main Menu 8 Show Data Menu 8 Function Descriptions 9 Download 9 Show Data 9 Version Identi er 10 Del...

Страница 3: ...bject The Lafayette MMT readily lends itself to large pre participation screenings or eld examinations where bulky more expensive systems do not The microprocessor control allows for storage of calibr...

Страница 4: ...l test time Data storage for up to 52 tests in on board memory peak force and time to reach peak force Manual or automatic storage of data Dual measurement range 0 300lbs 136 1kg or 0 50lbs 22 6kg Sel...

Страница 5: ...The unit is simply placed between the examiner s hand and the limb being tested The examiner s downward force is transmitted to the limb through the MMT unit The MMT is designed for one hand operatio...

Страница 6: ...esetting Changing the range causes the MMT to automatically reset and clear all time and force values Scroll LB KG Button The LB KG button has dual functionality depending on which screen is accessed...

Страница 7: ...e is displayed on the lower right of the Main Measurement Screen This value shows the total time that force has been applied After a test has ended this value shows the total length of the test in sec...

Страница 8: ...ction Descriptions for details on each option Download The Download function allows data to be transferred to a computer for permanent storage The download is accomplished via infrared connection to a...

Страница 9: ...n can not be established an error is given along with two audible beeps An option menu is then given which allows 1 a reattempt of communication or 2 canceling the operation The download device receiv...

Страница 10: ...U button 2 Press the SCROLL button one 1 time to move the cursor to SHOW DATA 3 Press ENTER to turn the display to SHOW DATA menu 4 Press the SCROLL button two 2 times to move the cursor to CLEAR ALL...

Страница 11: ...ove the cursor to BEEP 3 Press ENTER to turn on BEEP 4 Press the SCROLL button four 4 times to move the cursor to END 5 Press ENTER to exit the menu After the test time has ended no more data is measu...

Страница 12: ...nwanted data may inadvertently be stored The MMT will store all tests including test trials and force readings from inadvertent pressing of the load cell If a test requires that only a select number o...

Страница 13: ...limit Excessive force may cause permanent damage to the MMT or alter the calibration Caution Since the RESET button re zeros the MMT force should not be applied while the RESET button is pressed Reset...

Страница 14: ...m Battery Saver Mode 1 Press one of these four buttons RESET MENU ENTER or SCROLL 2 Pressing the RANGE button does not wake up the MMT Low Battery Detection The MMT is equipped with circuitry to detec...

Страница 15: ...3Photo CR17345 DL123ABU Panasonic CR123A Kodak K123L Acceptable Replacement Batteries Battery Change The battery of the MMT is accessed through a removable door in the face of the device The door is s...

Страница 16: ...ired to change the stirrups In the event that a stirrup breaks or becomes soiled new stirrups may be ordered through Lafayette Instrument Company Error and Message Screen Summary The MMT has special m...

Страница 17: ...FULL error is accompanied by two audible beeps The user must press the ENTER button to acknowledge and clear the warning They must then either discontinue storage by disabling the AUTO STORE feature o...

Страница 18: ...ngth because it takes into account the length of the muscle being tested The Lafayette Manual Muscle Test System MMT can be used to obtain torque values through a series of basic calculations Torque i...

Страница 19: ...Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Model 01163 User Instructions 19 Notes...

Страница 20: ...PO Box The items should be packed well insured for full value and returned along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative a...

Отзывы: