Lafayette 01163 Скачать руководство пользователя страница 1

3700 Sagamore Parkway North . PO Box 5729 . Lafayette, IN 47903 USA . Ph: 765-423-1505                                   Fax: 765-423-4111 . www.lafayetteinstrument.com . E-mail:[email protected]

Model 01163     User Instructions

3700 Sagamore Parkway North

P.O. Box 5729  •  Lafayette, IN 47903 USA

Tel:  765.423.1505  •  800.428.7545

Fax:  765.423.4111

E-mail: [email protected]    

www.lafayetteinstrument.com

© 2003 by Lafayette Instrument Company, Inc. All Rights Reserved-

Rel. 8.3.06

A revolutionary, hand-held strength measurement system

Model 01163

THE LAFAYETTE 

MANUAL MUSCLE TEST SYSTEM

      

U

SER’S 

M

ANUAL

Содержание 01163

Страница 1: ...P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com 2003 by Lafayette Instrument Company Inc All Rights R...

Страница 2: ...oll LB KG Button 6 Enter Store Button 6 Menu Button 6 Main Measurement Screen 7 Menu Descriptions 8 Main Menu 8 Show Data Menu 8 Function Descriptions 9 Download 9 Show Data 9 Version Identi er 10 Del...

Страница 3: ...bject The Lafayette MMT readily lends itself to large pre participation screenings or eld examinations where bulky more expensive systems do not The microprocessor control allows for storage of calibr...

Страница 4: ...l test time Data storage for up to 52 tests in on board memory peak force and time to reach peak force Manual or automatic storage of data Dual measurement range 0 300lbs 136 1kg or 0 50lbs 22 6kg Sel...

Страница 5: ...The unit is simply placed between the examiner s hand and the limb being tested The examiner s downward force is transmitted to the limb through the MMT unit The MMT is designed for one hand operatio...

Страница 6: ...esetting Changing the range causes the MMT to automatically reset and clear all time and force values Scroll LB KG Button The LB KG button has dual functionality depending on which screen is accessed...

Страница 7: ...e is displayed on the lower right of the Main Measurement Screen This value shows the total time that force has been applied After a test has ended this value shows the total length of the test in sec...

Страница 8: ...ction Descriptions for details on each option Download The Download function allows data to be transferred to a computer for permanent storage The download is accomplished via infrared connection to a...

Страница 9: ...n can not be established an error is given along with two audible beeps An option menu is then given which allows 1 a reattempt of communication or 2 canceling the operation The download device receiv...

Страница 10: ...U button 2 Press the SCROLL button one 1 time to move the cursor to SHOW DATA 3 Press ENTER to turn the display to SHOW DATA menu 4 Press the SCROLL button two 2 times to move the cursor to CLEAR ALL...

Страница 11: ...ove the cursor to BEEP 3 Press ENTER to turn on BEEP 4 Press the SCROLL button four 4 times to move the cursor to END 5 Press ENTER to exit the menu After the test time has ended no more data is measu...

Страница 12: ...nwanted data may inadvertently be stored The MMT will store all tests including test trials and force readings from inadvertent pressing of the load cell If a test requires that only a select number o...

Страница 13: ...limit Excessive force may cause permanent damage to the MMT or alter the calibration Caution Since the RESET button re zeros the MMT force should not be applied while the RESET button is pressed Reset...

Страница 14: ...m Battery Saver Mode 1 Press one of these four buttons RESET MENU ENTER or SCROLL 2 Pressing the RANGE button does not wake up the MMT Low Battery Detection The MMT is equipped with circuitry to detec...

Страница 15: ...3Photo CR17345 DL123ABU Panasonic CR123A Kodak K123L Acceptable Replacement Batteries Battery Change The battery of the MMT is accessed through a removable door in the face of the device The door is s...

Страница 16: ...ired to change the stirrups In the event that a stirrup breaks or becomes soiled new stirrups may be ordered through Lafayette Instrument Company Error and Message Screen Summary The MMT has special m...

Страница 17: ...FULL error is accompanied by two audible beeps The user must press the ENTER button to acknowledge and clear the warning They must then either discontinue storage by disabling the AUTO STORE feature o...

Страница 18: ...ngth because it takes into account the length of the muscle being tested The Lafayette Manual Muscle Test System MMT can be used to obtain torque values through a series of basic calculations Torque i...

Страница 19: ...Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Fax 765 423 4111 www lafayetteinstrument com E mail eval lafayetteinstrument com Model 01163 User Instructions 19 Notes...

Страница 20: ...PO Box The items should be packed well insured for full value and returned along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative a...

Отзывы: