Manikin Setup

System Setup

Setup f

or Sim

ulation

Clinical F

eatur

es

Maintenance

Tr

oubleshooting

Spar

e Par

ts

System Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

              

Common Learner Events can be customized via the Scenario and 
Event Handlers Editors. Select <Open Common Learner Events 
Editor> from the <Edit> menu.

All of the above mentioned editors can be accessed through the 
Instructor Application’s <Tools> menu, or directly through the 
Windows <Start> menu: 

•  Click the Windows <Start> button

•  Select the <Laerdal SimMan3G> program folder

•  Select the editor of your choice

Scenario Editor

The Scenario Editor allows you to define relationship between learner 
events and patient response by drawing lines in a simple graphical 
editor.

TRENDS

Trends are sets of physiological parameters pre-programmed to 
increase/decrease over time. They can be added to Instructor Mode 
Scenarios.

HANDLERS

Handlers are pre-programmed sets of actions and can be added to 
Instructor Mode Scenarios.

SIMMAN SCENARIOS TO SIMMAN 3G TRAUMA

SimMan Scenarios made with previous versions of the Scenario Editor 
must be converted to SimMan Scenarios in order to run and edit 
them.

To Convert SimMan Scenarios to 
SimMan 3G Trauma Scenarios:

Under <Tools> in the Instructor Application access the <Scenario 
Editor>, <Trend Editor> and <Handler Editor> respectively.

Create a backup copy of all old Scenarios prior to converting to 
SimMan 3G.

Launch the conversion wizard from the Scenario, Trend and 

Handler Editors as follows:

1  In each editor go <File> <Convert> <Old Scenarios>

2  Follow the instructions in the conversion wizard to convert 

Scenarios.

All old SimMan Scenarios will automatically be converted to a SimMan 
Classic style scenario, using the old event library.

We recommend that patient responses such as Eyes, Airway 
Resistance, be added manually to the updated Scenarios, to take full 
advantage of all new features in SimMan 3G.

Help Files

Software Help-files can be accessed as follows:
•  Click the Windows <Start> button

•  Select the <Laerdal SimMan 3G> folder from programs

•  Select the <Documentation> folder

•  Select the help file of your choice 

         Most applications will also display the corresponding Help file 

when pressing the <F1> key

Содержание SimMan 3G Trauma

Страница 1: ...SimMan 3GTrauma Directions for Use www laerdal com...

Страница 2: ......

Страница 3: ...les 24 Setup for Simulation 25 Using the Internal Compressor 25 Turning the Internal Compressor OFF 25 Changing default Compressor Settings 25 Air CO2 and Fluid Panel 26 Blood and Fluid System 26 Drai...

Страница 4: ...Network configuration WLAN setup Profile Editor Technical Assistance For technical assistance contact your local Laerdal Technical Service Center Web Downloads Visit http www laerdal com to download...

Страница 5: ...irs Interventions by learners are registered by the system in the session log and used for later debriefing Patient Monitor PC can be configured to replicate most patient monitors The web camera recor...

Страница 6: ...rules regulations or laws and is the sole responsibility of the customer The following precautions should be taken when using this product to avoid personal injury or damage to the product General Ma...

Страница 7: ...use automated chest compression machines on the manikin Mechanical or Electrical Hazards Warning Avoid pinch hazards Do not remove protective bushings from the manikin s joints or use the manikin wit...

Страница 8: ...e relevant airline Disassemble the legs from the torso and pack them into their respective cases before transportation or storage For instructions on how to disassemble the legs see Manikin Setup Atta...

Страница 9: ...hooting Spare Parts Manikin Setup SimMan 3GTrauma Overview power panel fluid fill panel DC Input 9 24V X XA Fluid Inlet Air Out Blood Inlet Activate Filling Bleeding ports Speakers Defib Connectors EC...

Страница 10: ...Left Leg Note Assemble the manikin on a large flat surface Attach the left leg before the right leg Open the torso to access the hip joint connectors To open the torso follow steps 1 4 Opening the Tor...

Страница 11: ...arent red tube Black twist and lock connector Right leg Black harness cable Black rectangular connector 4 lead Fluid from leg Tube blue White twist and lock connector Air from leg Colourless transpare...

Страница 12: ...pring then washer onto the bolt and feed through the arm 3 Tighten the screw with a Phillips head screw driver 4 Replace the deltoid pad Inserting and Connecting the Batteries Open the torso as descri...

Страница 13: ...is found on the right side of the manikin under a loose skin flap Lift the skin flap and pull out the protective cover To ensure easy access use the zippered clothing provided with the SimMan 3G manik...

Страница 14: ...upply 2 The battery indicator on the power panel shows the charge status of for the internal batteries External battery charging The battery charger comes with 5 international plugs Connect the approp...

Страница 15: ...nside the manikin Store batteries in a refrigerator i e temperature 0 C 4 C 32 F 40 F The two manikin batteries can be transported in the manikin during air freight When transporting spare batteries p...

Страница 16: ...start the simulation 10 The simulation system is now ready for use Power cables may be disconnected when batteries are charged Note Also refer to the Quick Setup Guide for detailed instructions on ini...

Страница 17: ...ting and also the default The default preshared key is SimMan3G This should however be changed with the SimMan 3G network configuration tool Connecting to an Existing Network If you would like to conn...

Страница 18: ...y of the following ways to the Session Log Using the General Events button Using the Event Search function Using the clickable manikin figure 5 PERFORMANCE The Performance window shows the effectivene...

Страница 19: ...an be viewed either as an average or in real time The window is minimized as a default To view the full display Click the Expand button to open the window 5 INSTRUCTOR PATIENT MONITOR The Instructor s...

Страница 20: ...e SimMan 3G will by default display the Classic view after conversion Opening an Auto Mode Patient Case To start a simulation in Auto Mode 1 Launch the Instructor Application on the Instructor PC 2 Se...

Страница 21: ...nts are registered automatically by the SimMan 3G manikin These events are highlighted blue and are marked with a wireless manikin icon Common Learner Events The Common Learner Events window lists the...

Страница 22: ...graph shows the patient status in terms of past current and predicted trend lines The timer in the top right corner shows how long the simulation has been running Depending on the scenario pre program...

Страница 23: ...omputer see the Patient Monitor Application Troubleshooting section in the SimMan3G Help files The Patient Monitor Interface 1 TOP MENU 1 Press wave in the top menu to view and change monitor display...

Страница 24: ...ecting the Main Setup button opens the Main Setup menu Options in the Main Setup menu are identical to the similar options displayed on the Menu line Selecting the Main Screen button enables an immedi...

Страница 25: ...between instructors can be added Accessing the Voice Conferencing Application The Voice Conference Application will launch automatically when connecting to a manikin The Voice Conference Application c...

Страница 26: ...to the same timeline and are always played back simultaneously Accessing the DebriefViewer The Laerdal DebriefViewer can be accessed in two ways 1 From the Instructor Application Click End Session Cl...

Страница 27: ...Scenarios made with previous versions of the Scenario Editor must be converted to SimMan Scenarios in order to run and edit them To Convert SimMan Scenarios to SimMan 3GTrauma Scenarios Under Tools in...

Страница 28: ...wear If using the manikin in high temperatures always allow the manikin to cool down between training sessions If the manikin is placed in a bed it should never be covered with a comforter duvet or qu...

Страница 29: ...lied with two fill units one Blood Fill Unit for blood and one Fluid Fill Unit for fluids secretions SIMMAN RIGHT LEG FILL PANEL The right leg fill panel is located at the top of the right leg near th...

Страница 30: ...l bottle with de ionized water Add 5 10 drops of Laerdal Blood colored concentrate mix and tighten the cap Run Manikin with External Blood 1 Drain the internal reservoir Follow instructions for Empty...

Страница 31: ...his action for both reservoirs CLEANING THE FLUID SYSTEM 1 From the Instructors application open Circulation and fluids tab check the Secretions box for urine and then select polyuria Check the Secret...

Страница 32: ...r OR De ionized water Priming the IV Arm System 1 Use a syringe to inject blood concentrate and 500 cc of water into an IV bag with tubing This will serve as the blood source Attach the blood source b...

Страница 33: ...osition on the skin Removing Wounds Flush all ports and tubes with 60 Isopropanol while the wounds are still attached When the fluid runs clear disconnect the tube from fluid outlet After the wound is...

Страница 34: ...right shoulder 6 Fit the Arm Adapter into the hole in the arm bracket from inside the torso Ensure the flat edge of the Adapter is facing the chest hinge Hand tighten the shoulder bolt 7 The Adapter...

Страница 35: ...eps 1 4 on page 7 2 Unscrew the hip joint connector Remove the leg cables tubes from the connector 3 Carefully remove the left leg with cables and tubes 4 Insert the AmputatedThigh with blood tube int...

Страница 36: ...e two pulse units Disconnect both units and route the wiring out of the foot Roll the wires together and store in the bottom of the ankle 3 Apply a liberal amount of baby powder inside of the Amputate...

Страница 37: ...d be aligned with the corresponding L or R on the upper dorsal thigh of the 3G manikin s leg 2 Apply a liberal amount of baby powder to the inside of the skin and leg and pull the skin all the way up...

Страница 38: ...ion do not exceed a defibrillation sequence of 3 shocks in 45 seconds followed by 1 minute of CPR After 30 minutes there must be at least 15 minutes with no shocking before starting a new sequence Not...

Страница 39: ...The pad can be exchanged for a male or female genitalia pad with urine catheter to simulate urine flow and catheterization Note The manikin legs do not need to be removed before the genitalia pad can...

Страница 40: ...completely filled 5 Reattach the Sternal tube to the Sternal IO pad 6 Place the Sternal IO unit in the Sternal Chassis Slide the unit down and towards the neck until it fits securely under the top ed...

Страница 41: ...band to expose theTibial IO module 3 Remove the IO tape Then remove the Tibial IO unit from the leg 4 Remove the tube from theTibial IO module 5 Remove theTibial IO Pad from theTibial IO chassis 6 Bef...

Страница 42: ...the module in place Roll the leg skin up over theTibial module TheTibial IO is now ready for simulation The following devices have been tested and are approved for use with the simulator BIG Automati...

Страница 43: ...module optional accessory Right arm amputation and bleeding module optional accessory The SimMan 3G arm adaptor kit is used to connect the trauma arm modules Contact your local Laerdal representative...

Страница 44: ...my Surgical cricothyrotomy The following manikin features indicate incorrect tube placement Right main stem intubation unilateral chest rise Stomach distention Lack of chest sounds CO2 exhalation see...

Страница 45: ...llback symptoms will occur unless the head is tilted back or jaw thrust maneuver is applied Breathing Features The SimMan3G can simulate spontaneous breathing Warning Do not ventilate the manikin with...

Страница 46: ...easured manually by auscultation of Korotkoff sounds Carotid brachial radial femoral popliteal dorsalis pedis and posterior tibialis pulses synchronized with ECG Pulse strength variable with BP Pulses...

Страница 47: ...or click the button to decrease bleeding rate Move slider to the right or click the button to increase bleeding rate 11 Connecting Wound Modules Wound modules can be placed on the skin Connect the wo...

Страница 48: ...yperactive Hypoactive Borborygmus Hypoactive postop Hyperactive diarrhea Hypoactive constipation Paralytic ileus 5 More Body Sounds Click the Adv Sounds Control to open the sounds control popup From h...

Страница 49: ...lowing settings from the drop down menu Wide open Half open Closed 5 Blinking Frequency Select one of the following settings from the drop down menu When activated these settings will change the blink...

Страница 50: ...ions Intraosseous access with needle insertion is possible through the sternum and left tibia The IO pads may be punctured numerous times before being replaced To replace the IO modules see the please...

Страница 51: ...port cases as illustrated in Manikin Setup Installing and Upgrading SimMan 3G software SimMan 3G software comes pre installed INSTRUCTOR PC AND PATIENT MONITOR PC 1 Power on computer and ensure no Sim...

Страница 52: ...ll updates and show which ones were performed successfully or failed Repeat from step 5 until all components are successfully updated Allow manikin time to save changes and reboot Do not power off man...

Страница 53: ...n session 1 Remove the neck skin velcro fasteners behind the neck 2 Remove the old strip of Crico tape 3 Replace with a new Crico tape 4 Ensure Crico tape completely covers and seals the opening to pr...

Страница 54: ...hest plate There is one bladder on each side of the chest plate assembly 2 Disconnect the tube from the bladder 3 Discard the used bladder 4 Insert new bladder 5 Reconnect the tube to the new bladder...

Страница 55: ...skin and put the stomach foam to the side 2 Open the hinged chest plate upwards to access the lungs 3 Remove the chest compression spring for easier access to the lungs 4 Unhook the yellow Lung Compl...

Страница 56: ...g from the skin make sure to properly position the skin halves and hold them together while zipping them closed Replacing Blood System Filter If reduced blood flow is experienced the filter may be clo...

Страница 57: ...located at the back of the head enough to reveal the ears Ensure that the microphone is positioned in the cup located towards the top of the ear with the black surface facing outwards VOICE CONFERENC...

Страница 58: ...r runs continuously The internal compressor may be worn contact LaerdalTechnical Service BLOOD SYSTEM Problem No blood flow Solution Make sure that the internal reservoir is filled with fluid Problem...

Страница 59: ...ay be old recommended lifetime is 200 discharge cycles Insert new batteries Compressor may not function properly consult your local LaerdalTechnical Services Centre PULSES Problem Cannot feel pedal pu...

Страница 60: ...tested with salt spray RF Communication WLAN frequency ranges 2 4 GHz WLAN channels 1 11 5 GHz WLAN channels 36 40 44 and 48 Operation range 100 m 300 ft outdoors RFID frequency ranges 13 56 MHz Oper...

Страница 61: ...eeve Patient Monitor 212 095xx Rugged Instructer PC 212 19650 Headset with microphone 245 96050 Webcam SimMan 3G Clothing 212 17450 Shirt 212 17650 Boxer Shorts 212 17750 Belt 212 17550 Trousers Fluid...

Страница 62: ......

Страница 63: ......

Страница 64: ...2012 Laerdal Medical AS All rights reserved 20 07343 Rev A...

Отзывы: