background image

 

 

MAINTENANCE AND IMPORTANT ADVICE 

17 

 

 

4.  

In the event of fire in the chimney, close 

the flue draught, close doors and windows, 
remove embers from the firebox, block the 
connection hole with damp cloths and call 
the fire brigade. 

 

 

 

 

4.3.

 

Important advice 

Lacunza 

recommends 

that 

only 

Lacunza-authorised  replacement  parts  be 
used.  

Lacunza  accepts  no  liability  for  any 

modification  to  the  product  which  it  has 
not authorised. 

This  appliance  is  a  heat-producing 

appliance and contact may lead to burns. 

This appliance may remain HOT for a 

period of time after it has gone out. MAKE 

SURE THAT SMALL CHILDREN DO NOT GO 

NEAR IT. 

Содержание AUSTRALIA Atlantic 610

Страница 1: ...Atlantic 610 Instruction Book AUSTRALIA ...

Страница 2: ...PRESENTATION OF THE APPLIANCE 1 1 ...

Страница 3: ...TALLER 6 2 1 Warning to installers 6 2 2 Room for installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7 2 3 3 Checks before lighting for the first time 7 2 3 4 Height adjustment and levelling the appliance 8 2 3 5 Connection to the flue 8 2 4 Chimney flue 8 2 4 1 Type of flue 8 2 4 2 C...

Страница 4: ...NCE 3 1 4 1 3 Flue socket 16 4 1 4 Painted sheet steel cast iron parts 16 4 1 5 Firebox glass 16 4 2 Maintenance of the chimney flue 16 4 3 Important advice 17 TROUBLESHOOTING 18 BASIC BREAKDOWNS 19 CERTIFICATE OF COMPLIANCE 20 ...

Страница 5: ...TPUT BURNING HARDWOOD kW 9 1 OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 64 PARTICULATE EMISSIONS FACTOR g kg 0 5 HIGH BURN Average power high primary air settings kW 9 1 Average Peak Power kW 11 8 Efficiency high primary air settings 58 Average dry fuel consumption rate high primary air settings Kg hr 2 9 Particulate emission factor oven dry wood high primary air settings g kg 0 3 MEDIUM BURN Ave...

Страница 6: ...f installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty To obtain these data tests have been done on the standards AS NZS 4012 2014 AS NZS 4013 2014 and AS NZS 2918 2018 with eucalyptus wood Figure No 1 Dimensions of the Atlantic 610 appliance in...

Страница 7: ...olutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated h...

Страница 8: ...appliance door and be placed centrally in the 920mm width The Thermal resistivity of the floor protector is 0 078m K W for 18mm thick compressed board sheets Combustible material cannot be stored closer than 50mm below the firebox in wood storage area 2 3 2 Safety distances Be sure to respect the appliance installation distances from combustible materials Bear in mind that it may even be necessary...

Страница 9: ...pliances without back boiler require an insulated double sleeve flue only on those sections that run outdoors or through cold areas Single piping can be used inside the building the heat of the gases serving to heat rooms insulating only those sections where excess temperature may cause damage If the chimney is constructed then it is necessary to pipe and insulate it to ensure correct updraught Th...

Страница 10: ... withstand high temperatures It must be possible to clean the entire flue no sections being left inaccessible for cleaning purposes 2 4 2 Chimney crown The upper end of the chimney must clear the roof the roof ridge or any obstacle located on the roof by at least 1m Figure No 3 Distances between chimney crown and roof ridge The chimney crown must clear the highest point of any neighbouring buildin...

Страница 11: ... the material insulation diameter airtightness cleanliness height verticality straightness chimney crown etc If sufficient updraught is not achieved by correcting the flue installation Lacunza supplies an accessory for exceptional cases a part which seals the top of the front part of the appliance and helps prevent smoke escaping into the room Logically this reduces both the view of the fire and t...

Страница 12: ... stored The logs should have a maximum diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech hardwood and eucalyptus logs Other fuels Oak chestnut ash maple birch elm etc Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All types of coal and liquid fuel Green wood Green or damp wood...

Страница 13: ...of the appliance 3 2 1 Operating components Figure No 8 Operating components on the appliance A Firebox door handle B Primary air intake o B1 open right o B2 closed left C Secondary air intake o C1 open right o C2 closed left D Double combustion air intake ...

Страница 14: ...no longer appear when the appliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Safety Do not store combustible materials beneath the appliance 3 5 Loading fuel In order to load firewood open the firebox door gently preventing the ...

Страница 15: ...utput open all the air intakes to the firebox and in order to obtain minimum output tend towards closing them For normal use we recommend you close the Primary Intake and leave the Secondary and Double Combustion Intakes open a High burn rate The appliance shall be operated with combustion rate controls fully open b Low burn rate The appliance shall be operated with all combustion rate controls ad...

Страница 16: ...e reinforcement In order to do this draw it towards the front of the appliance to release it from the vermiculite parts Figure No 11 First movement to release the reinforcement The vermiculite deflectors can then be extracted as shown Figure No 12 Extracting the vermiculite deflectors Extract the rest of the firebox vermiculite Figure No 13 Extract the rest of firebox vermiculites Figure No 14 Tur...

Страница 17: ... this task The cleaning should be carried out with the glass cold and taking care not to apply the glass cleaner directly on the glass as if it comes into contact with the door s closing cord it may deteriorate Put the cleaning product on the cloth Caution the vitro ceramic glass is prepared to support 700ºC Never let burning woods or combustion flame beating against the glass for prolonged period...

Страница 18: ...ll the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability for any modification to the product which it has not authorised This appliance is a heat producing appliance and contact may lead to burns This appliance may remain HOT for a period of time after it has gone out MAKE SURE THAT SMALL CHILDREN DO NOT GO NEAR...

Страница 19: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 20: ...026700014 Separador Ocean 1 6 Atlantic 610 Australia pieza móvil registro primario 1 7 Atlantic 610 Australia pieza móvil registro secundario 1 8 5000000945 Refuerzo deflector 1 9 502670000002 Cristal hogar Ocean 610 610R 1 502670000003 Cristal hogar Atlantic 610 610R 1 10 509020000042 Cordón Negro Ø13mm 3m 11 500000000510 Cordón plano pelos 8x2mm 2m 12 5040000904 Nickel Adour Parrilla hogar 1 13 ...

Страница 21: ...CERTIFICATE OF COMPLIANCE 20 7 CERTIFICATE OF COMPLIANCE ...

Страница 22: ...CERTIFICATE OF COMPLIANCE 21 7 ...

Страница 23: ...CERTIFICATE OF COMPLIANCE 22 7 ...

Страница 24: ......

Страница 25: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: