background image

 

 

MAINTENANCE AND IMPORTANT ADVICE 

18 

 

 

4.  

 

MAINTENANCE AND 

IMPORTANT ADVICE 

4.1.

 

Maintenance of the appliance 

The appliance, the flue connector piping 

and  the  flue  must  be  cleaned  regularly, 
particularly  following  long  periods  without 
use. 

4.1.1.

 

Firebox 

Clean the firebox area of ash, etc.  

4.1.2.

 

Inside the appliance 

Clean the firebox area of ash. Clean the 

deflectors, where soot may build up.  

4.1.3.

 

Flue socket 

The flue socket area must be kept clean 

at  all  times  for  the  appliance  to  work 
properly. 

It must be cleaned as often as required. 

How  often  it  is  cleaned  depends  on  how 
much the appliance is used and the type of 
fuel employed. 

4.1.4.

 

Painted sheet-steel-cast-iron parts. 

These  parts  should  be  cleaned  with  a 

brush  or  dry  cloth.  Do  not  dampen  the 
parts:  the  steel  could  rust  and  the  paint 
could  blister  and  chip.  Be  particularly 
careful when cleaning the glass: the liquids 
used must not dampen the painted steel. 

4.1.5.

 

Firebox glass 

Keep  the  secondary-air  intake  open  to 

keep  the  door  glass  cleaner  for  longer. 
However, the glass may get dirty the longer 
the  appliance  is  used.  Special  degreasing 

products  designed  for  the  purpose  should 
be used to clean it.  

Clean when the glass is cold and taking 

care not to apply the glass cleaner directly 
onto the glass as it could come into contact 
with the door-seal cord and damage it. 

4.2.

 

Maintenance of the chimney 

flue 

VERY  IMPORTANT:  In  order  to  avoid 

incidents  (chimney  fires,  etc.),  it  is 
necessary  to  perform  maintenance  and 
cleaning  operations  on  a  regular  basis;  if 
the  appliance  is  used  often,  then  the 
chimney  and  the  flue  connector  piping 
must be swept several times a year. 

In the event of fire in the chimney, close 

the flue draught, close doors and windows, 
remove embers from the firebox, block the 
connection hole with damp cloths and call 
the fire brigade. 

4.3.

 

Important advice 

Lacunza 

recommends 

that 

only 

Lacunza-authorised  replacement  parts  be 
used.  

Lacunza  accepts  no  liability  for  any 

modification  to  the  product  which  it  has 
not authorised. 

This  appliance  is  a  heat-producing 

appliance and contact may lead to burns. 

This appliance may remain HOT for a 

period of time after it has gone out. MAKE 

SURE THAT SMALL CHILDREN DO NOT GO 

NEAR IT. 

Содержание Atlantic 500

Страница 1: ...Atlantic 500 610 610R Instruction Book ...

Страница 2: ...TALLER 7 2 1 Warning to installers 7 2 2 Room for installation 7 2 2 1 Ventilation of the room 7 2 2 2 Location of the appliance in the room 8 2 3 Installation of the appliance 8 2 3 1 Floor 8 2 3 2 Safety distances 8 2 3 3 Checks before lighting for the first time 8 2 3 4 Height adjustment and levelling the appliance 8 2 3 5 Connection to the flue 8 2 4 Chimney flue 9 2 4 1 Type of flue 9 2 4 2 C...

Страница 3: ...1 4 1 3 Flue socket 18 4 1 4 Painted sheet steel cast iron parts 18 4 1 5 Firebox glass 18 4 2 Maintenance of the chimney flue 18 4 3 Important advice 18 TROUBLESHOOTING 19 BASIC BREAKDOWNS 20 DECLARATION OF PERFORMANCE 22 CE MARK 28 ...

Страница 4: ...N H O 79 78 75 CO emission at 13 O2 at N H O 0 11 0 11 0 11 Gas mass flow at N H O g s 8 0 10 6 10 5 Gas temperature downstream of flue socket at N H O ºC 259 285 305 Optimum flue draught Pa 12 12 12 Wood consumption beech at N H O kg h 2 4 3 49 3 10 Dimensions of the firebox Width mm 430 530 530 Depth mm 280 280 280 Useful height mm 220 470 470 Dimensions of the logs cm 40 50 50 Volume heated 45w...

Страница 5: ...PRESENTATION OF THE APPLIANCE 4 1 Figure No 1 Dimensions of the Ocean Atlantic 500 appliance in mm ...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Ocean Atlantic 610 appliance in mm ...

Страница 7: ...PRESENTATION OF THE APPLIANCE 6 1 Figure No 3 Dimensions of the Ocean Atlantic 610R appliance in mm ...

Страница 8: ...olutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated h...

Страница 9: ...t hand side 400 From the left hand side 400 From the rear 250 From the front 1000 From the top surface 750 Bear in mind that it may even be necessary to protect non combustible material in order to prevent breakage deformation etc as a result of overheating if the non combustible material is not designed to withstand high temperatures 2 3 3 Checks before lighting for the first time Make sure that ...

Страница 10: ...re length in order to ensure correct operation The flue must prevent the entry of rainwater The flue must be clean and airtight over its entire length The flue must be at least 6m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downdraught cowl a static cowl or a smoke extraction fan or re...

Страница 11: ...ances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 7 Distances between the chimney crown and objects within a radius of between 10 and 20m 2 4 3 Poor flue If not all the requirements indicated previously have been met smoke may escape from the appl...

Страница 12: ...ot achieved by correcting the flue installation Lacunza supplies an accessory for exceptional cases a part which seals the top of the front part of the appliance and helps prevent smoke escaping into the room Logically this reduces both the view of the fire and the loading aperture on the appliance Figure No 8 Accessory to help in the event of downdraught as a result of a poor flue This accessory ...

Страница 13: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Страница 14: ...econdary and double combustion air intake o C1 open right o C2 closed left 3 3 Lighting Use of the appliance in warm weather warm days early hours of the afternoon on sunny days may lead to lighting and updraught problems Certain weather conditions such as fog ice humidity entering the flue etc may hinder sufficient updraught in the flue and lead to suffocation Proceed as follows in order to light...

Страница 15: ...irewood open the firebox door gently preventing the sudden entry of air to the firebox so that smoke does not enter the room that the appliance is installed in Perform this operation with the glove to prevent burns to the hands The maximum load height is 2 logs with diameters of approx 10 cm The minimum interval between loads for nominal heat output is 60 minutes Always load with the nominal amoun...

Страница 16: ...nd leave the Secondary and Double Combustion Intakes open 3 7 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to prevent yourself from getting burned glove Never throw hot embers into the rubbish Access the ashpit by opening the door on the appliance 3 8 Deflectors The appliance has 2 vermic...

Страница 17: ... has an open and closed position When it is closed a lot of combustion gas is retained meaning that the flue and the fuel used must be in optimum conditions in order to ensure correct operation When open the deflector facilitates the passage of smoke Figure No 15 Stainless steel reinforcement in its closed position Figure No 16 Movements to change from closed to open Figure No 17 Stainless steel r...

Страница 18: ...be ensured Figure No 18 Movements to fit the circular deflector on the flue socket Ocean Atlantic 610R The 610R model also incorporates two stainless steel pieces in the hearth These pieces must be positioned as indicated in the image if all the values contained within the UNE EN 12815 UNE EN 13229 and UNE EN 13240 regulations are to be fulfilled Figure No 19 Stainless steel pieces 610R Given that...

Страница 19: ...ner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking care not to apply the glass cleaner directly onto the glass as it could come into contact with the door seal cord and damage it 4 2 Maintenance of the chimney flue VERY IMPORTANT In order to avoid inc...

Страница 20: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 21: ...BASIC BREAKDOWNS 20 6 BASIC BREAKDOWNS ...

Страница 22: ...a Ocean 610 2 502670000005 Trasera vermiculita Ocean 610R 1 5 504020000003 Parrilla cenicero Aralar 1 6 502570000004 Pieza móvil registro primario Ocean 1 7 502570000007 Pieza móvil registro secundario Ocean 1 502570000005 Refuerzo deflector Ocean 500 1 502620000002 Refuerzo deflector Ocean 600 610 1 502670000006 Refuerzo deflector Ocean 610R 1 502570000006 C ristal hogar Ocean 500 1 502620000003 ...

Страница 23: ...DECLARATION OF PERFORMANCE 22 7 DECLARATION OF PERFORMANCE ...

Страница 24: ...DECLARATION OF PERFORMANCE 23 7 ...

Страница 25: ...DECLARATION OF PERFORMANCE 24 7 ...

Страница 26: ...DECLARATION OF PERFORMANCE 25 7 ...

Страница 27: ...DECLARATION OF PERFORMANCE 26 7 ...

Страница 28: ...DECLARATION OF PERFORMANCE 27 7 ...

Страница 29: ...CE MARK 28 8 CE MARK ...

Страница 30: ...CE MARK 29 8 ...

Страница 31: ...CE MARK 30 8 ...

Страница 32: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: