Hardened Managed Ethernet Switch 

User’s Manual                                                                                            1 

Quick Start Guide 

This quick start guide describes how to install and use the 
Hardened Managed Ethernet Switch. This is the switch of 
choice for harsh environments constrained by space. 

 

Physical Description 

The Port Status LEDs and Power Inputs 

 

 

 

 

Содержание L-EX73000

Страница 1: ...l 1 Quick Start Guide This quick start guide describes how to install and use the Hardened Managed Ethernet Switch This is the switch of choice for harsh environments constrained by space Physical Description The Port Status LEDs and Power Inputs ...

Страница 2: ...X Orange Steady A valid network connection established Link ACT Flashing Transmitting or receiving data ACT stands for ACTIVITY Power Input Assignment Power3 12VDC DC Jack 12 48VDC Power2 Power Ground 12 48VDC Power1 Power Ground Earth Ground Terminal Block Relay Output Rating 1A 24VDC Relay Alarm Assignment FAULT Warning signal disable for following The relay contact closes if Power1 and Power2 a...

Страница 3: ... with 100 240VAC external power supply For Use with Model UP0351E 12P as power jack supply source by Universal Micro Electronics Co Ltd z Field Wiring Terminal Use Copper Conductors Only 60 75 14 24 AWG torque value 4 5 lb in z Operating voltage and Max current consumption 1 25A 12VDC 0 625A 24VDC 0 313A 48VDC Power consumption 15W Max z 40 to 75 40 to 167 operating temperature range Tested for fu...

Страница 4: ...t not the sealed device if any degradation is found z Sealed Relay Device information Sealed Device Relay Type V23079 A2008 B301 manufactured by Tyco Electronics Logistics Ag Relay Cover Manufacture of Plastic Material Ticona Designation of Plastic Material Vectra A130 Relay Epoxy Manufacture of Material Guangzhou Wells Chemical Co Ltd Designation of Material Type 6060RP Generic Name of Plastic Ma...

Страница 5: ...d by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port z Configuration settings of the terminal emulation program Baud rate 115 200bps Data bits 8 Parity none Stop bit 1 Flow control none z Press the Enter key The Command Line Interface CLI screen should appear as below z Logon to Exec Mode View Mode At the switch_a l...

Страница 6: ..._a prompt will show on the screen z Logon to Configure Mode Configure Terminal Mode At the switch_a prompt just type in configure terminal and press Enter to logon to Configure Mode or Configure Terminal Mode And the switch_a config prompt will show on the screen Web Configuration z Login the switch Specify the default IP address 192 168 1 10 of the switch in the web browser A login window will be...

Страница 7: ...Hardened Managed Ethernet Switch User s Manual 7 z Enter the factory default login ID root Enter the factory default password no password Then click on the Login button to log on to the switch ...

Страница 8: ...Hardened Managed Ethernet Switch 8 User s Manual ...

Страница 9: ...o deliver full scalability with SNMP RMON web based management functions by providing To get the most out of this manual you should have an understanding of Ethernet networking concepts In this manual you will find Features on the Hardened Managed Ethernet Switch z Illustrative LED functions z Installation instructions z Management Configuration z SNMP DHCP IGMP z Specifications ...

Страница 10: ...TCH MANAGEMENT 19 Web based browser interface 19 Administration console via RS 232 serial port CLI 19 External SNMP based network management application 19 Installation 20 SELECTING A SITE FOR THE SWITCH 20 WIRING DIAGRAM 21 CONNECTING TO POWER 21 12VDC DC Jack 21 Redundant DC Terminal Block Power Inputs 22 Alarms for Power Failure 22 CONNECTING TO YOUR NETWORK 23 Cable Type Length 23 Cabling 23 S...

Страница 11: ... UNDERSTANDING THE BROWSER INTERFACE 35 SYSTEM 37 PORT 49 SWITCHING 54 TRUNKING 58 STP RING 59 VLAN 68 QOS 75 SNMP 78 802 1X 84 OTHER PROTOCOLS 89 Command Line Console Management 95 ADMINISTRATION CONSOLE 95 Exec Mode View Mode 96 Privileged Exec Mode Enable Mode 100 Configure Mode Configure Terminal Mode 104 SYSTEM 108 PORT 116 SWITCHING 121 TRUNKING 126 STP RING 127 VLAN 141 QOS 147 SNMP 150 802...

Страница 12: ... Switch 12 User s Manual Product Overview Hardened Managed Ethernet Switch Front and Bottom View Package Contents When you unpack the product package you shall find the items listed below Please inspect the contents and report ...

Страница 13: ...Hardened Managed Ethernet Switch User s Manual 13 any apparent damage or missing items immediately to your rnet Switch Manual RS232 cable authorized reseller The Hardened Managed Ethe User s ...

Страница 14: ...ower and port link failure by relay output z Power Supply Redundant DC Terminal Block power inputs and 12VDC DC JACK with 100 240VAC external power supply For Use with Model UP0351E 12P as power jack supply source by Universal Micro Electronics Co Ltd z Field Wiring Terminal Use Copper Conductors Only 60 75 14 24 AWG torque value 4 5 lb in z Operating voltage and Max current consumption 1 25A 12VD...

Страница 15: ...s Logistics Ag Relay Cover Manufacture of Plastic Material Ticona Designation of Plastic Material Vectra A130 Relay Epoxy Manufacture of Material Guangzhou Wells Chemical Co Ltd Designation of Material Type 6060RP Generic Name of Plastic Material Epoxy Resin Management Support VLAN z Port based VLAN z IEEE802 1Q tagged VLAN TRUNKING z MAC based Trunking with automatic link fail over PORT SECURITY ...

Страница 16: ...MANAGEMENT METHODS z Console port access via RS 232 cable CLI Command Line Interface z Telnet remote access z SNMP agent MIB 2 RFC1213 Bridge MIB RFC1493 RMON MIB RFC2819 statistics history alarm and events VLAN MIB IEEE802 1Q RFC2674 Private MIB z Web browser z TFTP software upgrade capability ...

Страница 17: ... Panel Display z POWER This LED comes on when the switch is properly connected to power and turned on z Port Status LEDs The LEDs are located on the front panel displaying status for each respective port Please refer to the following table for more details ...

Страница 18: ... Flashing Transmitting or receiving data ACT stands for ACTIVITY Physical Ports The Hardened Managed Ethernet Switch provides 16 port 10 100Base TX 100Base FX 2 port combo Gigabit Hardened Managed Ethernet Switch CONNECTIVITY z RJ 45 connectors on TX ports z ST or SC connector on 100Base FX fiber port z SC connector on 1000Base SX LX fiber port MODE SELECTION z 10Base T full duplex mode z 10Base T...

Страница 19: ...lets user access full switch configuration and functionality from a Netscape or Internet Explorer browser Administration console via RS 232 serial port CLI The switch provides an onboard serial port which allows the switch to be configured via a directly connected terminal External SNMP based network management application The switch can also be configured via SNMP ...

Страница 20: ...eme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 40 C to 75 40 to 167 The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the switch receives adequate ventil...

Страница 21: ...DC Terminal Block Power Inputs or 12VDC DC Jack 12VDC DC Jack Step 1 Connect the supplied AC to DC power adapter to the receptacle on the topside of the switch Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage ...

Страница 22: ...ms for Power Failure Step 1 There are two pins on the terminal block used for power failure detection It provides the normally closed output when the power source is active Use this as a dry contact application to send a signal for power failure detection Power Input Assignment Power3 12VDC DC Jack 12 48VDC Power2 Power Ground 12 48VDC Power1 Power Ground Earth Ground Terminal Block Relay Output R...

Страница 23: ...bling requirements Cable Specifications Speed Connector Port Speed Half Full Duplex Cable Max Distance 10Base T RJ 45 10 20 Mbps 2 pair UTP STP Cat 3 4 5 100 m 100Base TX RJ 45 100 200 Mbps 2 pair UTP STP Cat 5 100 m 1000Base T RJ 45 2000 Mbps 4 pair UTP STP Cat 5 100 m 100Base FX ST SC 100 200 Mbps MMF 50 or 62 5µm 2 km 100Base FX ST SC 100 200 Mbps SMF 9 or 10µm 15 40 or 75 km 1000Base SX SC 200...

Страница 24: ...use Step 3 Consult Cable Specifications Table on previous page for cabling requirements based on connectors and speed Step 4 Connect one end of the cable to the switch and the other end to a desired device Step 5 Once the connections between two end devices are made successfully turn on the power and the switch is operational ...

Страница 25: ...tem It also contains information about port connection options This chapter covers the following topics Management Access Overview Key Concepts Key Guidelines for Implementation Web Management Access Administration Console Access SNMP Access Standards Protocols and Related Reading Management Access Overview The switch gives you the flexibility to access and manage the switch using any or all of th...

Страница 26: ... console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port When using the management method configure the terminal emulation program to use the following parameters you can change these settings after login DEFAULT PARAMETERS 115 200bps 8 data bits No parity 1 stop bit This management method is often pr...

Страница 27: ... the switch remotely After you set up your IP address for the switch you can access the switch s web interface applications directly in your web browser by entering the IP address of the switch You can then use your web browser to list and manage switch configuration parameters from one central location just as if you were directly connected to the switch s console port SNMP Based Network Manageme...

Страница 28: ...andard management protocol for multivendor IP networks SNMP supports transaction based queries that allow the protocol to format messages and to transmit information between reporting devices and data collection programs SNMP runs on top of the User Datagram Protocol UDP offering a connectionless mode service Management Architecture All of the management application modules use the same Messaging ...

Страница 29: ...r Management The switch provides a web based browser interface for configuring and managing the switch This interface allows you to access the switch using a preferred web browser This chapter describes how to configure the switch using its web based browser interface ...

Страница 30: ...y collects statistics about a LAN segment or VLAN The RMON probe transfers the collected data to a management workstation on request or when a pre defined threshold is reached The management workstation collects the statistics that the RMON probe gathers The workstation can reside on the same network as the probe or it can have an in band or out of band connection to the probe The switch provides ...

Страница 31: ... of manageable objects in various layers of the TCP IP protocol suites MIB II covers all manageable objects from layer 1 to layer 4 and as a result is the major SNMP MIB supported by all vendors in the networking industry The switch supports a complete implementation of SNMP Agent and MIB II RMON MIB RFC 2819 and Bridge MIB RFC 1493 The switch provides hardware based RMON counters in the switch ch...

Страница 32: ...k management application Bridge Groups Supported The switch supports the following four groups of Bridge MIB RFC 1493 The dot1dBase Group a mandatory group that contains the objects applicable to all types of bridges The dot1dStp Group contains objects that denote the bridge s state with respect to the Spanning Tree Protocol If a node does not implement the Spanning Tree Protocol this group will n...

Страница 33: ...onfiguring and managing the switch This interface allows you to access the switch using a preferred web browser This chapter describes how to configure the switch using its web based browser interface Logging on to the switch SWITCH IP ADDRESS In your web browser specify the IP address of the switch Default IP address is 192 168 1 10 ...

Страница 34: ...er the factory default login ID root PASSWORD Enter the factory default password no password Or enter a user defined password if you followed the instructions later and changed the factory default password Then click on the Login button to log on to the switch ...

Страница 35: ...ging the switch SYSTEM System Information System Name Password IP Address Save Configuration Firmware Upgrade Alarm Setting Reboot Logout PORT Configuration Port Status Rate Control RMON Statistics Per Port Vlan Activities SWITCHING Bridging Static MAC Entry Port Mirroring TRUNKING Port Trunking STP RING Global Configuration RSTP Port Setting MSTP Properties MSTP Instance Setting MSTP Port Setting...

Страница 36: ...LAN Mode Setting 802 1Q VLAN Setting 802 1Q Port Setting Port Based VLAN QOS Global Configuration 802 1p Priority DSCP SNMP SNMP General Setting SNMP v1 v2c SNMP v3 802 1X Radius Configuration Port Based Authentication OTHER PROTOCOLS GVRP IGMP Snooping NTP ...

Страница 37: ...Hardened Managed Ethernet Switch User s Manual 37 System System Information View System information VLAN ID IP Address and IP Subnet Mask of the Switch ...

Страница 38: ...ace the current system name with a new one 2 Updating setting Click Updating setting button to update your settings 3 Password Click in Password text box Type a password 4 Retype Password Click in Retype Password text box Type the same password in Password text box again to verify it 5 Updating setting Click Updating setting button to update your settings ...

Страница 39: ...the switch after IP or subnet mask are changed 5 Default Gateway Click Default Gateway drop down menu to choose Disable or Enable from the Default Gateway drop down list to disable or enable Default Gateway Setting for the switch Click the text box and type a new address to change the Default Gateway Need to choose Enable from the Default Gateway drop down menu 6 Submit Click Submit button when yo...

Страница 40: ...d Click Load button to load the file from the TFTP server 2 Backup config to TFTP server Click in TFTP Server text box and type the TFTP server IP address to where the file will be back upped Click in FILE text box and type the name of the file that will be back upped Click Backup button to backup the file to the TFTP server 3 Save Configuration Click Save Configuration button to save your configu...

Страница 41: ...e text box and type the name of the file that you intend to upgrade it to the switch 2 TFTP server IP Click in TFTP server IP text box and type the TFTP server IP address from where the file will be obtained 3 Upgrade Click upgrade button to upgrade firmware to the switch Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other function...

Страница 42: ...rdened Managed Ethernet Switch 42 User s Manual Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other functions during this period of time ...

Страница 43: ...Hardened Managed Ethernet Switch User s Manual 43 ...

Страница 44: ...Hardened Managed Ethernet Switch 44 User s Manual Firmware has been upgraded successfully to the switch Reboot the switch after completing the upgrade process ...

Страница 45: ...Hardened Managed Ethernet Switch User s Manual 45 ...

Страница 46: ...u to choose fe1 fe16 ge1 ge2 or Power1 Power3 from the Name drop down list 2 Trigger Enabled Click Trigger Enabled drop down menu to choose YES or NO from the Trigger Enabled drop down list to enable or disable Trigger 3 Update Setting Click Update Setting button to update settings to the switch ...

Страница 47: ...Hardened Managed Ethernet Switch User s Manual 47 Reboot Reboot Click Reboot button to restart the switch ...

Страница 48: ...Hardened Managed Ethernet Switch 48 User s Manual Logout Logout Click Logout button to logout of the switch ...

Страница 49: ...o disable or enable Admin Setting for the port 2 Speed Click Speed drop down menu to change the line speed and duplex settings from the Speed drop down list for the port 3 Flow control Click Flow control drop down menu to choose Disable or Enable from the Flow control drop down list to disable or enable Flow control for the port 4 Submit Click Submit button when you finished configurations ...

Страница 50: ...Hardened Managed Ethernet Switch 50 User s Manual Port Status View the Link Status Speed Duplex and Flow control status for all ports ...

Страница 51: ...ge the Ingress Rate Control for the port Rate Values 64kbps 128kbps 192kbps 1792kbps 2Mbps 3Mbps 4Mbps 100Mbps 104Mbps 112Mbps 120Mbps 1000Mbps Note M 1024k 2 Egress Click in Egress text box and type a new Rate to change the Egress Rate Control for the port Rate Values 64kbps 128kbps 192kbps 1792kbps 2Mbps 3Mbps 4Mbps 100Mbps ...

Страница 52: ...ch 52 User s Manual 104Mbps 112Mbps 120Mbps 1000Mbps Note M 1024k 3 Update setting Click Update setting button when you finished these Rate Control settings RMON Statistics Click Port 1 Port 18 to view corresponding RMON Statistics ...

Страница 53: ...Hardened Managed Ethernet Switch User s Manual 53 Per port vlan activities Click Port 1 Port 18 to view corresponding vlan activities ...

Страница 54: ...thernet Switch 54 User s Manual Switching Bridging 1 Aging Time seconds Click the text box and type a decimal number as Bridging Aging Time in seconds 2 Update setting Click update setting button when you finished Aging ...

Страница 55: ...e 4 Storm control enabled type Choose Broadcast and or DLF Multicast from Storm control enabled type for the port 5 Update Setting Click Update Setting button when you finished Threshold level and Storm control enabled type settings Static MAC Entry Static MAC Entry Forward 1 Add MAC address Click in Add MAC address text box and type a locked forwarding MAC address for the port 2 VLAN ID Click VLA...

Страница 56: ...ry Forward settings Static MAC Entry Discard 1 Add MAC address Click in Add MAC address text box and type a MAC address to be discarded for the port 2 VLAN ID VLAN ID Click VLAN ID drop down menu and choose a VLAN ID from the VLAN ID drop down list 3 Delete MAC address Click Delete MAC address drop down menu and choose a MAC address from the Delete MAC address drop down list to be discarded from t...

Страница 57: ...rom Port 1 Port 18 2 Mirror To Click Mirror To drop down menu to Choose Mirror To port Port 1 Port 18 from Mirror To drop down list 3 Mirror Mode Click Mirror Mode drop down menu to Choose Tx Rx Tx or Rx from Mirror Mode drop down list 4 Submit Click Submit button when you finished Port Mirroring settings ...

Страница 58: ...unking Port Trunking Static Channel Group 1 Trunk 1 Click Port 1 Port 16 to assign ports to Trunk 1 Maximum 4 ports in Trunk 1 GE Trunking 1 Trunk 3 Click Static or Disable for Trunk 3 2 Submit Click Submit button when you finished Port Trunking settings ...

Страница 59: ...0 61440 Click in Bridge Priority text box and type a decimal number between 0 and 61440 3 Hello Time sec 1 9 Click in Hello Time text box and type a decimal number between 1 and 9 4 Max Age sec 6 28 Click in Max Age text box and type a decimal number between 6 and 28 5 Forward Delay sec 4 30 Click in Forward Delay text box and type a decimal number between 4 and 30 6 STP Version Click STP Version ...

Страница 60: ...orward packets first A lower number denotes a higher priority This entry must be divisible by 16 The default priority setting is 128 4 Admin Path Cost Click in Admin Path Cost text box and enter a value between 0 and 2000000 to set the Admin Path Cost for the port 0 auto Setting 0 for the Admin Path Cost will automatically set the speed for forwarding packets to the port for optimal efficiency Def...

Страница 61: ...ed Ethernet Switch User s Manual 61 Disable or Auto from Edge Port drop down list to set Enable Disable or Auto Edge Port for the port 7 Update setting Click Update setting button when you finished RSTP Port Setting ...

Страница 62: ...is a region by itself unless specifically added to one 3 Revision Level Click in Revision Level text box to specify the number for configuration information The default value of revision number is 0 4 Max Hops Click in Max Hops text box to specify the maximum allowed hops for BPDU in an MST region This parameter is used by all the instances of the MST Specifying the max hops for a BPDU prevents th...

Страница 63: ...Hardened Managed Ethernet Switch User s Manual 63 ...

Страница 64: ...etting Click Update setting button when you finished VLAN Instance Configuration Included VLANs 1 Instance ID Click Instance ID drop down menu to choose instance ID from Instance ID drop down list 2 Included VLAN Click Included VLAN drop down menu to choose VLAN from Included VLAN drop down list Instance Setting 1 Bridge Priority 0 61440 Click in Bridge Priority text box to set the bridge priority...

Страница 65: ...Hardened Managed Ethernet Switch User s Manual 65 ...

Страница 66: ...nce ID from Instance ID drop down list MSTP Port Configuration 1 Port Click Port drop down menu to choose port from Port drop down list 2 Priority Granularity 16 Click in Priority text box to set the port priority for a bridge group The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN or which port s...

Страница 67: ...etting Ring state 1 Click Ring state drop down menu from Ring state drop down list to choose Enable or Disable to enable or disable Ring state 2 Update setting Click Update setting button when you finished Ring state setting Set ring port 1 Ring port 1 Click Ring port 1 drop down menu to choose Ring port 1 from Ring port 1 drop down list 2 Ring port 2 Click Ring port 2 drop down menu to choose Rin...

Страница 68: ...ual VLAN VLAN Mode Setting 1 VLAN Mode Setting Click VLAN Mode Setting drop down menu to choose Tag based VLAN or Port based VLAN from VLAN Mode Setting drop down list 2 Update Setting Click Update Setting button when you finished VLAN Mode Setting ...

Страница 69: ...Hardened Managed Ethernet Switch User s Manual 69 ...

Страница 70: ...k in the VLAN ID textbox and specify a new VLAN ID number from 2 4094 4 VLAN Name Click in the VLAN Name textbox and type a name for this newly created VLAN Add port to or delete port from VLAN 1 VLAN Member Choose the port to be added to or deleted from the VLAN 2 Tag or Untag Click Tag or Untag drop down menu to Choose Tag or Untag from Tag or Untag drop down list for a Hybrid port 3 Submit Clic...

Страница 71: ... Click VLAN setting The VLAN Setting window appears 2 Delete VLAN Click Delete VLAN button 3 Select a VLAN ID Click Select a VLAN ID drop down menu from Select a VLAN ID drop down list to choose the VLAN to be deleted 4 Submit Click Submit button when you finished VLAN setting ...

Страница 72: ...wn menu to choose Access Trunk or Hybrid from Mode drop down list for the port The port will be Tag port if you choose Trunk Mode for the port And the port will be Tag or Untag port if you choose Hybrid Mode for the port 3 PVID Click in the PVID textbox and specify a new PVID number for the port 4 Update Setting Click Update Setting button when you finished VLAN Port Setting ...

Страница 73: ...Hardened Managed Ethernet Switch User s Manual 73 ...

Страница 74: ... be added to or deleted from the VLAN 2 Select all Click select all button to choose Port 1 Port 18 all to be added to the VLAN 3 Delete all Click delete all button to choose Port 1 Port 18 all to be deleted from the VLAN 4 Submit Click Submit button when you finished Port Based VLAN setting ...

Страница 75: ...port to trust the DSCP Differentiated Service Code Point labels of all traffic received on that port 3 Policy Choose Strict Priority Queue3 WRR Queue0 2 or WRR Queue0 3 A strict priority queue is always emptied first The queues that are used in the WRR Weighted Round Robin are emptied in a round robin fashion and you can configure the weight for each queue 4 Weighted Round Robin Click in the Weigh...

Страница 76: ... Ethernet Switch 76 User s Manual 802 1p Priority 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for VLAN Priority 0 7 2 Submit Click Submit button when you finished 802 1p priority ...

Страница 77: ...ed Managed Ethernet Switch User s Manual 77 DSCP 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for DSCP Priority 0 63 2 Submit Click Submit button when you finished DSCP ...

Страница 78: ...dened Managed Ethernet Switch 78 User s Manual SNMP SNMP General Setting 1 SNMP Status Click SNMP Status drop down menu from SNMP Status drop down list to choose Enable or Disable to enable or disable SNMP ...

Страница 79: ...art Trap Click Warm Start Trap drop down menu from Warm Start Trap drop down list to choose Enable or Disable to enable or disable warm start trap 9 Link Down Trap Click Link Down Trap drop down menu from Link Down Trap drop down list to choose Enable or Disable to enable or disable link down trap 10 Link Up Trap Click Link Up Trap drop down menu from Link Up Trap drop down list to choose Enable o...

Страница 80: ...et Community Name Click in the Get Community Name textbox and specify a get community name 2 Set Community Name Click in the Set Community Name textbox and specify a set community name 3 Update Setting Click Update Setting button when you finished SNMP V1 V2c Setting ...

Страница 81: ...Hardened Managed Ethernet Switch User s Manual 81 ...

Страница 82: ...the Auth Password textbox and specify an authentication password y SNMPv3 Auth SHA Add a user using SNMP v3 with authentication Click in the Auth Password textbox and specify an authentication password y SNMPv3 Priv Auth MD5 Add a user using SNMP v3 with authentication and privacy Click in the Auth Password textbox and specify an authentication password Click in the Privacy PassPhrase textbox and ...

Страница 83: ...d a user using SNMP v3 with read only access mode y Read Write Add an user using SNMP v3 with read write access mode 5 Sumit Click Sumit button when you finished SNMP V3 Setting Delete User 1 Delete User Click Delete User button The Select User Name window appears 2 Select User Name Click Select User Name drop down menu from Select User Name drop down list to choose the user to be deleted from usi...

Страница 84: ...dius Configuration 1 Radius Status Click Radius Status drop down menu from Radius Status drop down list to choose Enable or Disable to globally enable or disable authentication 2 Update Setting Click Update Setting button when you finished Radius Status Setting ...

Страница 85: ...itch and radius server This key must match the encryption used on the radius daemon All leading spaces are ignored but spaces within and at the end of the key are used If spaces are used in the key do not enclose the key in quotaion marks unless the quotation marks themselves are part of the key 5 Timeout 1 1000 Click in the Timeout textbox and specify the time interval in seconds that the Switch ...

Страница 86: ...utton The Select Radius Server IP window appears 2 Select Radius Server IP Click Select Radius Server IP drop down menu from Select Radius Server IP drop down list to choose the IP address of the remote radius server host to be deleted 3 Sumit Click Sumit button when you finished radius server deletion ...

Страница 87: ...from Port Control drop down list to choose Auto Force Authorized or Force Unauthorized to force a port state Auto specifies to enable authentication on port Force Authorized specifies to force a port to always be in an authorized state Force Unauthorized specifies to force a port to always be in an unauthorized state 4 Periodic Reauthentication Click Periodic Reauthentication drop down menu from P...

Страница 88: ...ardened Managed Ethernet Switch 88 User s Manual reauthorization attempts The default time is 3600 seconds 6 Update Setting Click Update Setting button when you finished port based authentication setting ...

Страница 89: ...Hardened Managed Ethernet Switch User s Manual 89 Other Protocols ...

Страница 90: ...Disable to enable or disable GVRP for the port 2 GVRP applicant Click GVRP applicant drop down menu from GVRP applicant drop down list to choose Active or Normal to the port Ports in the GVRP active applicant state send GVRP VLAN declarations when they are in the STP Spanning Tree Protocol blocking state which prevents the STP bridge protocol data units BPDUs from being pruned from the other port ...

Страница 91: ...m VLAN ID drop down list to choose the VLAN under configuration for the switch 4 IGMP version Click IGMP version drop down menu from IGMP version drop down list to choose 1 2 or 3 for the switch 5 Fast leave Click fast leave drop down menu from fast leave drop down list to choose Enable or Disable for the switch Enable this function will allow members of a multicast group to leave the group immedi...

Страница 92: ...Enable or Disable for the switch Use this command to enable report suppression for IGMP version 1 and version 2 Report suppression does not apply to IGMP version 3 and is turned off by default for IGMP versionn1 and IGMP version 2 reports The switch uses IGMP report suppression to forward only one IGMP report per multicast router query to multicast devices When IGMP router suppression is enabled t...

Страница 93: ... Click in the NTP Server textbox and specify the IP address or Domain name of NTP server 3 Sync Time Click Sync Time button to synchronize time with NTP server 4 Time Zone Click Tmie Zone drop down menu from Tmie Zone drop down list to set time zone 5 Polling Interval 1 10080 min Click in the Polling Interval textbox and specify the polling interval 6 Update Setting Click Update Setting button whe...

Страница 94: ...one PDT Pacific Daylight Saving Time Zone ADT Alaska Daylight Saving Time Zone 4 Weekday Click in the textboxes and specify the daylight saving period Month Click Month drop down menu from Month drop down list to choose from January to December Week 1 5 Specifies weekdays from Monday to Friday Day Click Day drop down menu from Day drop down list to choose from Sunday to Saturday Hour 0 23 Specifie...

Страница 95: ...ommend Line Administration Console Connect the DB9 straight cable to the RS 232 serial port of the device to the RS 232 serial port of the terminal or computer running the terminal emulation application Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch console port When us...

Страница 96: ...d Managed Ethernet Switch 96 User s Manual Exec Mode View Mode Logon to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon to Exec Mode or View Mode switch_a login root ...

Страница 97: ...lp facility Access this help by typing in the full or partial command string then typing a question mark The CLI displays the command keywords or parameters along with a short description At the switch_a prompt just press to list the above basic commands switch_a At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or pa...

Страница 98: ...ec Mode or View Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon ...

Страница 99: ...thernet Switch User s Manual 99 back to Exec Mode or View Mode switch_a login root Exit from Exec Mode View Mode At the switch_a prompt just type in exit and press Enter to exit from Exec Mode or View Mode switch_a exit ...

Страница 100: ...de At the switch_a prompt just type in enable and press Enter to logon to Privileged Exec Mode or Enable Mode And the switch_a prompt will show on the screen switch_a enable Commands Privileged Exec Mode or Enable Mode allows users to run commands as following At the switch_a prompt just press to list the commands switch_a ...

Страница 101: ...hernet Switch User s Manual 101 At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a show ...

Страница 102: ...ed Exec Mode or Enable Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon ...

Страница 103: ...User s Manual 103 back to Exec Mode or View Mode switch_a login root Exit from Privileged Exec Mode or Enable Mode At the switch_a prompt just type in exit and press Enter to exit from Privileged Exec Mode or Enable Mode switch_a exit ...

Страница 104: ... just type in configure terminal and press Enter to logon to Configure Mode or Configure Terminal Mode And the switch_a config prompt will show on the screen switch_a configure terminal Commands Configure Mode or Configure Terminal Mode serves as a gateway into the modes as following At the switch_a config prompt just press to list the commands switch_a config ...

Страница 105: ...Switch User s Manual 105 At the switch_a config prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a config show ...

Страница 106: ... Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen Logon back to Exec Mode View Mode At the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root ...

Страница 107: ...ernet Switch User s Manual 107 Exit from Configure Mode or Configure Terminal Mode At the switch_a config prompt just type in exit and press Enter to exit from Configure Mode or Configure Terminal Mode switch_a config exit ...

Страница 108: ...o hostname HOSTNAME HOSTNAME specifies the network name of the system 4 Example The following example sets the hostname to switch and shows the change in the prompt switch_a config hostname switch switch config Password 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use enable password command...

Страница 109: ...s and prefix length of an interface M specifies IP subnet mask 8 255 0 0 0 16 255 255 0 0 24 255 255 255 0 4 Example The following example sets the new IP address 192 168 1 10 and new IP subnet mask 255 255 255 0 to switch switch_a config interface vlan1 1 switch_a config if ip address 192 168 1 10 24 switch_a config if Default Gateway 1 Command Mode Configure mode Logon to Configure Mode Configur...

Страница 110: ... ADDRESS A B C D specifies the IP address of the DNS server 4 Example The following example sets the DNS server 192 168 1 100 to switch switch_a config ip dns 192 168 1 100 switch_a config Save Configuration Load config from TFTP server 1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use install image comman...

Страница 111: ...ing example backups configuration file to tftp server IP address 192 168 1 100 switch_a write config file 192 168 1 100 switch_a Save Configuration 1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use copy running config startup config command to write configurations to the file to be used at startup This is ...

Страница 112: ...ll show on the screen switch_a config 2 Usage Use this command to enable auto save configuration function The configuration will be automatically saved at every configured interval while this command is enabled Use the no form of this command to disable this feature 3 Command Syntax service auto config enable no service auto config enable 4 Example The following example enables or disables auto sa...

Страница 113: ... 1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use install image command to upgrade firmware from tftp server to switch 3 Command Syntax install image IP ADDRESS WORD IP ADDRESS specifies the IP address of tftp server WORD specifies the file name to be upgraded to switch 4 Example The following example spe...

Страница 114: ...Hardened Managed Ethernet Switch 114 User s Manual At the switch_a prompt just type in reload and press Enter to reboot the switch after completing the upgrade process ...

Страница 115: ...onfig alarm trigger if fe1 switch_a config Alarm trigger power 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to enable or disable alarm trigger of power source 3 Command Syntax no alarm trigger power POWER POWER specifies the power source 4 Example The following example enabl...

Страница 116: ... Usage Use logout command to exit from the Exec mode or Privileged Exec mode 3 Command Syntax logout 4 Example The following example specifies to exit from the Exec mode or Privileged Exec mode switch_a logout switch_a login Port Configuration Port Status Rate Control RMON Statistics Per Port Vlan Activities Configuration Admin Setting 1 Command Mode Interface mode Logon to Configure Mode Configur...

Страница 117: ...de fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use duplex command to specify the duplex mode to be used for each interface Use the no duplex to disable this function 3 Command Syntax no duplex MODE MODE specifies the duplex mode auto full half 4 Example The following example shows the use of duplex MODE full to the...

Страница 118: ...mmand Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage Use the show interface command to display interface configuration and status 3 Command Syntax show interface IFNAME IFNAME specifies the name of the interface for which status and configuration information is...

Страница 119: ...ng example shows the use of rate control ingress VALUE 10 mega bits to the interface fe1 port 1 switch_a config interface fe1 switch_a config if rate control ingress 10m switch_a config if RMON Statistics 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage...

Страница 120: ...ged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage Use show vlan command to display information about a particular VLAN by specifying the VLAN ID 3 Command Syntax show vlan 2 4094 2 4094 VLAN ID 4 Example The following is an output of show vlan command displaying information about VLAN 2 switch_a show vlan 2 ...

Страница 121: ...TIME 10 1000000 The number of seconds of persistence 4 Example The following example sets the new AGEINGTIME 1000 to bridge GROUP 1 switch_a config bridge 1 ageing time 1000 switch_a config Threshold level 0 100 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a c...

Страница 122: ...mmand to enable broadcast traffic Use no storm control broadcast command to disable broadcast traffic 3 Command Syntax storm control broadcast enable no storm control broadcast 4 Example The following example shows setting storm control broadcast enable to the interface fe1 port 1 switch_a config interface fe1 switch_a config if storm control broadcast enable switch_a config if Multicast 1 Command...

Страница 123: ... the screen switch_a config interface fe1 switch_a config if 2 Usage Use storm control dlf enable command to enable destination lookup failure traffic Use no storm control dlf command to disable destination lookup failure traffic 3 Command Syntax storm control dlf enable no storm control dlf dlf destination lookup failure 4 Example The following example shows setting storm control dlf enable to th...

Страница 124: ... in vlan VLANID 2 switch_a config bridge 1 address 2222 2222 2222 forward fe1 vlan 2 switch_a config Static MAC Entry Discard 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to statically configure a bridge entry to discard matching frames 3 Command Syntax bridge GROUP address ...

Страница 125: ...g by the destination port on the specified source port 3 Command Syntax mirror interface SOURCEPORT direction SNOOPDIRECTION no mirror interface SOURCEPORT SOURCEPORT Name of the Source interface to be used SNOOPDIRECTION both receive transmit both Specifies mirroring of traffic in both directions receive Specifies mirroring of received traffic transmit Specifies mirroring of transmitted traffic 4...

Страница 126: ...o create a static aggregator or add a member port to an already existing static aggregator Use the no static channel group command to detach the port from the static aggregator 3 Command Syntax static channel group 1 3 no static channel group 1 3 Channel group number Maximum 4 ports in static channel group 1 and static channel group 2 Maximum 2 ports in static channel group 3 4 Example The followi...

Страница 127: ...sed for bridging PROTOCOL ieee IEEE 802 1Q spanning tree protocol mstp IEEE 802 1s multiple spanning tree protocol rstp IEEE 802 1w rapid spanning tree protocol 4 Example The following example chooses the PROTOCOL rstp on bridge GROUP 1 switch_a config bridge 1 protocol rstp vlan bridge switch_a config Multiple Spanning Tree Protocol 1 Command Mode Configure mode Logon to Configure Mode Configure ...

Страница 128: ...the no form of the command to disable the Rapid Spanning Tree protocol on a bridge 3 Command Syntax bridge GROUP rapid spanning tree enable no bridge GROUP rapid spanning tree enable BRIDGE FORWARD GROUP 1 1 Bridge group name used for bridging BRIDGE FORWARD Puts all ports of the specified bridge into the forwarding state 4 Example The following example enables or disables the rapid spanning tree ...

Страница 129: ...nal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set bridge priority for the common instance Using a lower priority indicates a greater likelihood of the bridge becoming root 3 Command Syntax bridge GROUP priority PRIORITY no bridge GROUP priority GROUP 1 1 The ID of the bridge group for which the priority is set PRIORITY 0 61440 The bridge pr...

Страница 130: ...n to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set the max age for a bridge Use the no parameter with this command to restore the default value of max age 3 Command Syntax bridge GROUP max age MAXAGE no bridge GROUP max age GROUP 1 1 The ID of the bridge group to which this maximum age time is assigned MAXA...

Страница 131: ...a config bridge 1 forward time 30 switch_a config RSTP Port Setting Priority Granularity 16 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set the port priority for a bridge The lower priority...

Страница 132: ... to be assigned to the group 4 Example The following example sets the cost 123 of the interface fe1 port 1 of bridge GROUP 1 switch_a config interface fe1 switch_a config if bridge 1 path cost 123 switch_a config if Point to Point Link 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show ...

Страница 133: ... Usage Use spanning tree autoedge command to assist in automatic identification of the edge port Use the no spanning tree autoedge command to disable this feature 3 Command Syntax no spanning tree autoedge 4 Example The following example enables the spanning tree autoedge of the interface fe1 port 1 switch_a config interface fe1 switch_a config if spanning tree autoedge switch_a config if Edgeport...

Страница 134: ...nning tree mst configuration switch_a config mst 2 Usage Use this command to create an MST region and specify a name to it MST bridges of a region form different spanning trees for different VLANs By default each MST bridge starts with the region name as its bridge address This means each MST bridge is a region by itself unless specifically added to one 3 Command Syntax bridge GROUP region REGION_...

Страница 135: ...1 revision 25 switch_a config mst Max Hops 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify the maximum allowed hops for BPDU in an MST region This parameter is used by all the instances of the MST Specifying the max hops for a BPDU prevents the messages from looping ...

Страница 136: ...he bridge group ID INSTANCE_ID 1 15 Specify the instance ID VLAN_ID 1 4094 Specify multiple VLAN IDs corresponding to the bridge instance 4 Example The following example associates multiple VLANs 10 and 20 to instance 1 of bridge GROUP 1 switch_a config bridge 1 protocol mstp switch_a config spanning tree mst configuration switch_a config mst bridge 1 instance 1 vlan 10 20 switch_a config mst Brid...

Страница 137: ... switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to assign a Multiple Spanning Tree instance to a port Use the no parameter with this command to remove the instance 3 Command Syntax bridge GROUP instance INSTANCE_ID no bridge GROUP instance INSTANCE_ID GROUP 1 1 Specify the bridge group ID INSTANCE_ID Specify the instance ...

Страница 138: ...y the port priority in a range of 0 240 4 Example The following example sets the port priority 121 for Multiple Spanning Tree instance 3 to a port fe1 in bridge GROUP 1 switch_a config interface fe1 switch_a config if bridge group 1 instance 3 priority 121 switch_a config if Bridge Group Instance Path Cost 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to ...

Страница 139: ...eter with this command to disable Ring state 3 Command Syntax bridge GROUP ring enable no bridge GROUP ring enable bridge forward GROUP 1 1 Specify the bridge group ID 4 Example The following example enables Ring state in bridge GROUP 1 switch_a config bridge 1 ring enable switch_a config Set ring port 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a confi...

Страница 140: ...Hardened Managed Ethernet Switch 140 User s Manual switch_a config ring set port fe1 fe2 switch_a config ...

Страница 141: ... VLAN 1 Command Mode VLAN Configure mode Logon to Configure Mode Configure Terminal Mode Logon to VLAN Configure Mode The switch_a config vlan prompt will show on the screen switch_a config vlan database switch_a config vlan 2 Usage This command enables or disables the state of a particular VLAN on a bridge basis Specifying the disable state causes all forwarding over the specified VLAN ID on the ...

Страница 142: ... prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use switchport mode access command to set the switching characteristics of the Layer 2 interface to access mode and classify untagged frames only Use the no switchport access command to reset the mode of the Layer 2 interface to access default 3 Command Syntax switchport mode access no switchport access 4 Exam...

Страница 143: ... fe1 port 1 and all frames to be received on interface fe1 port 1 switch_a config interface fe1 switch_a config if switchport mode hybrid acceptable frame type all switch_a config if Switchport mode trunk 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config i...

Страница 144: ... vlan remove VLANID no switchport hybrid vlan all Allow all VLANs to transmit and receive through the Layer 2 interface none Allow no VLANs to transmit and receive through the Layer 2 interface add Add a VLAN to the member set remove Remove a VLAN from the member set VLANID 2 4094 The ID of the VLAN or VLANs that will be added to or removed from the Layer 2 interface For a VLAN range specify two V...

Страница 145: ...NID switchport trunk allowed vlan except VLANID no switchport trunk vlan all Allow all VLANs to transmit and receive through the Layer 2 interface none Allow no VLANs to transmit and receive through the Layer 2 interface add Add a VLAN to transmit and receive through the Layer 2 interface remove Remove a VLAN from transmit and receive through the Layer 2 interface except All VLANs except the VLAN ...

Страница 146: ... fe1 switch_a config if 2 Usage Use this command to set or remove the default VLAN for the interface 3 Command Syntax switchport portbase add remove vlan VLANID VLANID The ID of the VLAN will be added to or removed from the Layer 2 interface 4 Example The following example specifies to add the interface fe1 port 1 to VLANID 2 switch_a config interface fe1 switch_a config if switchport portbase add...

Страница 147: ...4 Example The following example globally enables QoS on the switch switch_a config mls qos enable switch_a config Trust 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use mls qos trust command to turn on QoS trust CoS or DSCP Use the no mls qos trust command to turn off QoS trust CoS or DSCP 3...

Страница 148: ...g priority queue out switch_a config Weighted Round Robin 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use wrr queue bandwidth command to specify the bandwidth ratios of the transmit queues 3 Command Syntax wrr queue bandwidth WRR_WTS WRR_WTS Weighted Round Robin WRR weights for the 4 queues...

Страница 149: ... on the switch switch_a config wrr queue cos map 1 0 1 switch_a config DSCP 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use mls qos map dscp queue command to map the DSCP values to a queue 3 Command Syntax mls qos map dscp queue DSCP_VALUE to QUEUE_ID DSCP_VALUE DSCP values Up to 8 values s...

Страница 150: ...he following example enables SNMP to the switch switch_a config snmp server enable switch_a config Description 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server description command to specify and no snmp server description command to remove description for SNMP 3 Command Syntax sn...

Страница 151: ...tch_a config snmp server location location switch_a config Contact 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server contact command to specify and no snmp server contact command to remove contact for SNMP 3 Command Syntax snmp server contact CONTACT no snmp server contact CONTACT...

Страница 152: ... Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify trap host IP address for SNMP Use the no parameter with this command to remove trap host IP address for SNMP 3 Command Syntax snmp server trap ipaddress 1 5 IP ADDRESS no snmp server trap ipaddress 1 5 1 5 The trap host IP addre...

Страница 153: ...ure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable warmStart command to enable warm start trap for SNMP Use the no snmp server trap type enable warmStart command to disable warm start trap for SNMP 3 Command Syntax no snmp server trap type enable warmStart 4 Example The following examp...

Страница 154: ...ble linkUp command to enable link up trap for SNMP Use the no snmp server trap type enable linkUp command to disable link up trap for SNMP 3 Command Syntax no snmp server trap type enable linkUp 4 Example The following example enables link up trap for SNMP switch_a config snmp server trap type enable linkUp switch_a config Authentication Failure Trap 1 Command Mode Configure mode Logon to Configur...

Страница 155: ...e no snmp server trap type enable topologyChange command to disable topology change trap for SNMP 3 Command Syntax no snmp server trap type enable topologyChange 4 Example The following example enables topology change trap for SNMP switch_a config snmp server trap type enable topologyChange switch_a config SNMP v1 v2c Get Community Name 1 Command Mode Configure mode Logon to Configure Mode Configu...

Страница 156: ... NAME The set community name for SNMP 4 Example The following example specifies set community name name for SNMP switch_a config snmp server community set name switch_a config SNMP v3 SNMPv3 No Auth 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Add a user using snmp v3 with read only or read ...

Страница 157: ...write access mode md5 authentication method sha authentication method AUTH_PASSWORD authentication password 4 Example The following example adds a user myuser using snmp v3 with read write access mode and MD5 authentication mypassword switch_a config snmp server v3 user myuser rw auth md5 mypassword switch_a config SNMPv3 Priv Auth MD5 SNMPv3 Priv Auth SHA 1 Command Mode Configure mode Logon to Co...

Страница 158: ... method AUTH_PASSWORD authentication password PRIV_PASS_PHRASE encryption pass phrase 4 Example The following example adds a user myuser using snmp v3 with read write access mode MD5 authentication mypassword and encryption pass phrase mypassphrase switch_a config snmp server v3 user myuser rw priv md5 mypassword des mypassphrase switch_a config ...

Страница 159: ...trl switch_a config Radius Server IP Radius Server Port 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify the IP address of the remote radius server host and assign authentication and accounting destination port number 3 Command Syntax no radius server host IP ADDRESS ...

Страница 160: ...the IP address 192 168 1 100 of the remote radius server host and set the secret key ipi shared among the radius server and the 802 1x client switch_a config radius server host 192 168 1 100 key ipi switch_a config Timeout 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to spec...

Страница 161: ...a value in the range 1 to 100 4 Example The following example specifies the retransmit value 12 switch_a config radius server retransmit 12 switch_a config Port Based Authentication Authentication State 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config int...

Страница 162: ...uthorized no dot1x port control auto Specify to enable authentication on port force authorized Specify to force a port to always be in an authorized state force unauthorized Specify to force a port to always be in an unauthorized state 4 Example The following example specifies to enable authetication on the interface fe1 port 1 switch_a config interface fe1 switch_a config if dot1x port control au...

Страница 163: ...t1x timeout re authperiod SECS no dot1x timeout re authperiod SECS 1 4294967295 Specify the seconds between reauthorization attempts The default time is 3600 seconds 4 Example The following example specifies to set the interval 25 seconds between reauthorization attempts switch_a config interface fe1 switch_a config if dot1x timeout re authperiod 25 switch_a config if ...

Страница 164: ...idge 3 Command Syntax set gvrp enable bridge GROUP set gvrp disable bridge GROUP GROUP Bridge group ID used for bridging 4 Example The following example globally enables GVRP to bridge GROUP 1 switch_a config set gvrp enable bridge 1 switch_a config Dynamic VLAN creation 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen...

Страница 165: ... in a bridge 3 Command Syntax set port gvrp enable all IFNAME set port gvrp disable all IFNAME all All ports added to recently configured bridge IFNAME The name of the interface 4 Example The following example enables GVRP on the interface fe1 port 1 switch_a config set port gvrp enable fe1 switch_a config Per port setting GVRP applicant 1 Command Mode Configure mode Logon to Configure Mode Config...

Страница 166: ...ration and deregistration on the port fixed Specify the multicast groups currently registered on the switch are applied to the port but any subsequent registrations or deregistrations do not affect the port Any registered multicast groups on the port are not deregistered based on the GARP timers forbidden Specify that all GVRP multicasts are deregistered and prevent any further GVRP multicast regi...

Страница 167: ...re mode or Interface mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a configure terminal switch_a config switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp snooping command to enable IGMP Snooping When this com...

Страница 168: ...rotocol version number 4 Example The following example sets the IGMP protocol version 3 on the interface fe1 port 1 switch_a config interface fe1 switch_a config if ip igmp version 3 Fast leave 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interfac...

Страница 169: ...ommand to configure the frequency of sending IGMP host query messages To return to the default frequency use the no ip igmp query interval command 3 Command Syntax ip igmp query interval INTERVAL no ip igmp query interval INTERVAL 1 18000 Frequency in seconds at which IGMP host query messages are sent 4 Example The following example changes the frequency of sending IGMP host query messages to 2 mi...

Страница 170: ...rt 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp snooping mrouter interface command to statically configure the specified VLAN constituent interface as a multicast router interface for IGMP S...

Страница 171: ...ble report suppression 3 Command Syntax no ip igmp snooping report suppression 4 Example The following example enables report suppression for IGMPv2 reports on vlan1 1 switch_a config interface vlan1 1 switch_a config if ip igmp version 2 switch_a config if ip igmp snooping report suppression NTP NTP Status 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a ...

Страница 172: ...le The following example specifies the IP address 192 168 1 100 of NTP server switch_a config ntp server 192 168 1 100 switch_a config Sync Time 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use ntp sync time command to synchronize time with NTP server 3 Command Syntax ntp sync time 4 Example...

Страница 173: ...he polling interval 3 Command Syntax ntp polling interval MINUTE MINUTE 1 10080 The polling interval Enter a value in the range 1 to 10080 minutes 4 Example The following example specifies the polling interval 60 minutes switch_a config ntp polling interval 60 switch_a config Daylight Saving Mode 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prom...

Страница 174: ...MONTH HOUR MINUTE DAY MONTH HOUR MINUTE OFFSET TIMEZONE Specifies the daylight saving timezone DAY 1 31 Specifies from 1 to 31 MONTH 1 12 Specifies from January to December HOUR 0 23 Specifies from 0 to 23 MINUTE 0 59 Specifies from 0 to 59 OFFSET 1 1440 Specifies from 1 to 1440 minutes no clock summer time 4 Example The following example sets clock summer time TIMEZONE onehour as daylight saving ...

Страница 175: ...at 5 Up to 100m 328ft MMF 50 or 62 5µm SMF 9 or 10µm MMF 50 or 62 5µm SMF 9 or 10µm LED Indicators Per unit Power status Power 1 Power 2 Power 3 Per port 10 100TX 100FX Link ACT 10 100 1000TX Green 1000SX LX Orange Link ACT Dimensions 65mm W x 125mm D x 145mm H 2 56 W x 4 92 D x 5 71 H Net Weight 1Kg 2 2lbs Power Input DC Jack 12VDC External AC DC required Terminal Block 12 48VDC Operating Voltage...

Страница 176: ... 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards EN61000 4 11 Voltage Dips Standards Environmental Test Compliance IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock IEC60068 2 32 Ed Free Fall NEMA TS1 2 Environmental requirements for traffic control equipment ...

Страница 177: ...tch User s Manual 177 Appendix A DB9 DCE pin assignment Pin no Name RS232 Signal name 1 DCD Data Carrier detect 2 RxD Received data 3 TxD Transmit data 4 N C 5 GND Signal ground 6 DSR Data set Ready 7 N C 8 CTS Clear to send 9 N C ...

Страница 178: ...rope Bratislava Poland EET 2EETDST Asia Nicosia EET Europe Minsk Europe Sofia Europe Athens Europe Vilnius Europe Chisinau Europe Istanbul Europe Kiev Europe Uzhgorod Europe Zaporozhye Europe Nicosia Asia Istanbul Europe Tiraspol Turkey GMT0BST Europe London Europe Dublin Eire Europe Belfast GB GB Eire WET0WETDST WET Atlantic Faeroe Atlantic Madeira Atlantic Canary PWT0PST Europe Lisbon Portugal M...

Страница 179: ...enter America Menominee America Costa_Rica America Managua CST6CDT US Central SystemV CST6CDT EST5EDT America New_York America Kentucky Louisville America Kentucky Monticello America Detroit America Pangnirtung America Louisville EST5EDT US Eastern US Michigan SystemV EST5EDT AST4ADT America Thule Atlantic Bermuda SystemV AST4ADT EST5 America Coral_Harbour America Cayman America Jamaica America Pa...

Страница 180: ...orto_Acre Brazil Acre NORO2 America Noronha Brazil DeNoronha CST4CDT Antarctica Palmer America Santiago Chile Continental EIST6EIDT Pacific Easter Chile EasterIsland Asia MST 8 Asia Kuala_Lumpur Asia Kuching CST 8 Asia Harbin Asia Shanghai Asia Chongqing Asia Urumqi Asia Kashgar Asia Hong_Kong Asia Macau Asia Macao Hongkong PRC ROC Oceania CST 9 30CDT Australia Adelaide Australia Broken_Hill Austr...

Страница 181: ... Zulu UCT1 Atlantic Cape_Verde Etc GMT 1 UCT2 Atlantic South_Georgia Etc GMT 2 UCT3 Antarctica Rothera America Belem America Cayenne America Paramaribo Etc GMT 3 UCT4 America Anguilla America Antigua America Barbados America Dominica America Grenada America Guadeloupe America Martinique America Montserrat America Puerto_Rico America St_Kitts America St_Lucia America St_Vincent America Tortola Amer...

Страница 182: ...hu Africa Khartoum Africa Dar_es_Salaam Africa Kampala Antarctica Syowa Asia Bahrain Asia Kuwait Asia Qatar Asia Riyadh Asia Aden Etc GMT 3 UCT 4 Indian Mauritius Indian Reunion Indian Mahe Asia Muscat Etc GMT 4 UCT 5 Indian Kerguelen Indian Maldives Asia Karachi Asia Dushanbe Asia Ashgabat Asia Samarkand Asia Tashkent Etc GMT 5 UCT 5 45 Asia Katmandu UCT 6 Antarctica Mawson Antarctica Vostok Asia...

Страница 183: ...co_City America Lima Mexico General CST6 America Regina America Swift_Current Canada East Saskatchewan Canada Saskatchewan SystemV CST6 EET 2EETDST2 Europe Bucharest EET 2EETDST3 Europe Tallinn Europe Helsinki Europe Riga Europe Mariehamn EET 2EETDST2W2K Europe Istanbul UCT 14 Pacific Kiritimati Etc GMT 14 UCT9 30 Pacific Marquesas UCT12 Etc GMT 12 North America Canada PST8PDT_CA America Vancouver...

Страница 184: ...te MST7MDT_MX America Chihuahua America Hermosillo America Mazatlan Mexico BajaSur CST6CDT_MX America Guatemala North America Turks and Caicos EST5EDT_TC America Grand_Turk Additions Since 10g RTM EST5EDT_INDIANA America Indiana Indianapolis America Indiana Marengo America Indiana Vevay America Fort_Wayne America Indianapolis America Indiana Knox America Knox_IN US Indiana Starke US East Indiana U...

Отзывы: