Lacme Birdy Скачать руководство пользователя страница 7

8

1

3

2

Return signal LED - B

1

2

Pilot lamp - A

1

3

2

V

out

   

1 500 V 

³

V

out

   

2 000 V 

³

V

out

   

2 500 V 

³

V

out

   

3 000 V 

³

V

out

   

4 000 V 

³

V

out

   

5 000 V 

³

V

out

   

6 000 V 

³

V

out

 

   

7 000 V

³

Bar-graph operation indicator of the fence. 
Each LED indicates a level of the output voltage (Vout) of the energizer.

Led alarm :

 V

out 

<

 

1 500 V

very little vegetation

average vegetation

 V

output 

 

oltage 

Display

Voltage reading 
by each Sentinel responder 
when installed.

thick vegetation

= Green backlight when all is well. 

= Backlight flashing red when the voltage is no longer sufficient to guard, or if a fault is found by the sentinels. In this case 

the element is in error at the flashing display. 

The 

Clos 

2006-D

 

to indicate the voltage at the point where it is installed. 

 can be associated with sentinel responders (1 to 4) for increased guard security The responder is used

 

Specific instructions for sentinel responders comes with them.

Connexion example with a sentinel responder :

Terminal 1 :

 

to be connected to the 

EARTH 

connexion.

Terminal 2 : to be connected to the fence as 

“TOTAL POWER OUTPUT”

.

Terminal 1 :

 

to be connected to the 

EARTH 

connexion

.
Terminal 2 : to be connected to the fence as 

“TOTAL POWER OUTPUT”

.

Terminal 3 : as an option, to be connected to the fence as 

“REDUCED POWER

OUTPUT” 

as well as the 

return signal test

.

Pilot lamp - A

Clos 2000-6 D

Clos 2000-1 / Clos 2000-2 / Clos 2000-3 / Clos 2000-4 / Clos 2000-6

Clos 2000-4 Led /Clos 2000-6 Led/ Clos 2000-6 D

Clos 2000-4 Led /Clos 2000-6 Led/ Clos 2000-6 D

Содержание Birdy

Страница 1: ...n EN User guide DE Bedienungsanleitung ES Instrucciones de empleo IT Manuale di istruzioni P 3 P 6 P 9 P 12 P 15 Electrificateurs Weidezaunger te Electrificadores Elettrificatori Energizers Electrific...

Страница 2: ...voquer une d gradation des conducteurs et une perte d efficacit Brancher la prise de courant sur le secteur le voyant lumineux t moin de bon fonctionnement doit s allumer au rythme des impulsions envi...

Страница 3: ...boucl e en retour permanent sur la borne 3 de l appareil le voyant lumineux B permet de surveiller le bon fonctionnement de cette branche 3 B Exemple de branchement sortie puissance r duite Exemple d...

Страница 4: ...ue un niveau de tension de sortie Vout de l lectrificateur Led d alarme Vout 1 500 V Tr s peu de v g tation V g tation moyenne Affichage de la tension de sortie Affichage de la tension vue par les r p...

Страница 5: ...he voltage and energy levels are sufficient to correctly guard the animals Only regular checks using a controller on the fence line can ensure this 6 power max output energy j energy at 500 ohms volta...

Страница 6: ...terminal 3 of the unit the LED B allows to monitor the proper functioning of this fence 3 B Schema example reduced power Example of a loop connection 3 Fence wire connected to the HIGH OUTPUT POWER an...

Страница 7: ...the flashing display The Clos 2006 D to indicate the voltage at the point where it is installed can be associated with sentinel responders 1 to 4 for increased guard security The responder is used Sp...

Страница 8: ...sicherheit der Tiere dank einer ausreichenden Zaunspannung und Energie gew hrleistet wird Nur regelm ige Kontrollen des Zauns k nnen dies best tigen INBETRIEBNAHME 9 DE Stromver sorgung Max Ausgang sl...

Страница 9: ...seinem Ende mit Klemme 3 des Ger ts verbunden R cklaufanschluss kann ber die Kontrollleuchte B berwacht werden ob dieser Bereich ordnungsgem funktioniert Mit dieser Konfiguration leuchtet die gr ne Ko...

Страница 10: ...ete Anzeige blinkt rot wenn die H tespannung nicht mehr ausreicht oder bei den Sentinel Transpondern ein Fehler festgestellt wird In diesem Fall blinkt das fehlerhafte Element auf der Anzeige An Clos...

Страница 11: ...imadamente cada 1 5 segundos Cuidado este testigo no garantiza que los niveles de tensi n y energ a est n suficientes para asegurar la guardia de los animales Solamente controles regulares sobre la l...

Страница 12: ...rolar el buen funcionamiento de este sector 3 B Ejemplo de conexi n salida de potencia reducida Ejemplo de conexi n en bucle 3 Alambre de cerca conectado a la salida potencia total Ejemplo de alambre...

Страница 13: ...la cerca como SALIDA DE POTENCIA TOTAL 1 2 Piloto de funcionamiento A 1 3 2 Vout 1 500 V Vout 2 000 V Vout 2 500 V Vout 3 000 V Vout 4 000 V Vout 5 000 V Vout 6 000 V Vout 7 000 V Gr fico de barras q...

Страница 14: ...irca ogni 1 5 secondi Attenzione questo indicatore non garantisce che i livelli di tensione e di energia siano sufficienti per garantire la guardia dei animali Soli i controlli regolari sulla linea di...

Страница 15: ...iare il corretto funzionamento di questo collegamento 3 B Esempio di collegamento uscita potenza ridotta Esempio di collegamento ciclico 3 Cavo recinto collegato all uscita potenza totale Esempio di c...

Страница 16: ...RA Morsetto 2 collegare al recinto come USCITA POTENZA TOTALE 1 2 Spia di funzionamento A 1 3 2 Vout 1 500 V Vout 2 000 V Vout 2 500 V Vout 3 000 V Vout 4 000 V Vout 5 000 V Vout 6 000 V Vout 7 000 V...

Отзывы: