4

SITTING

GAS CONNECTION

CAUTION:

• 

The buyer agrees to install the appliance in accordance with recognised best practices and the 

regulations in force.

• 

Any technical operation such as installation, repair or adjustment of the appliance must be carried 

out by a qualified technician.

• 

Do not lift the appliance by the front rail. Damages caused in this way are not covered by the 

warranty.

• 

If the appliance is to be installed against a wall or partition, or close to furniture or decorative 

railing or skirting, these must be made of fireproof material. Otherwise, they must be lined with a 

fireproof material. Special attention must be given to all fire prevention regulations. The flooring 

in the room where the appliance is to be installed must be capable of withstanding temperatures 

above 65°C.

• 

Install a suitable extractor hood above the range cooker.

DELIVERY AND UNPACKING:

The appliance is delivered on a wooden pallet, packed with cardboard.

• 

Unpack and check the appliance for damage upon receipt. In case of damage, mark the delivery 

note  accordingly,  and  within  48  hours  notify  the  carrier  in  writing  by  registered  mail  with 

acknowledgement of receipt.

• 

To release the appliance from the pallet, use a 10 mm Allen key to remove the screws under the 

pallet.

• 

Remove the wooden pallet and put the appliance on the floor, taking care not to lift it by the front 

rail.

Natural gas:

Since 1st July 1997, an automatic shut-off valve must be fitted to all new installation or whenever an

existing shut-off valve is replaced.

LPG (butane-propane):
Propane gas:

The installation must have a class-1 safety regulator.

Connect the appliance to the outlet of a 4 kg/h regulator. Recommended dual bottles to inlet of

regulator for correct operation of the appliance during prolonged periods at full capacity. Supply from

35 kg bottle or from tank is possible and recommended (connection to appliance using approved

LPG flexible hose with maximum length of 2 m).

Butane gas:

The connection must be made using a butane safety regulator fitted to the bottle (connection to

appliance using approved LPG flexible hose with maximum length of 2 m).

Connect the appliance to the outlet of a 2.6 kg/h regulator. Recommended dual bottles to inlet of

regulator for correct operation of the appliance during prolonged periods at full capacity.

CONNECTION:

 The appliance is equipped with a Ø15/21 male connector

    

 , 1/2" gas, 

thread, to the back of the appliance.

  For  a  correct  supply,  use  an  approved  flexible  connector  of  suitable 

characteristics, such as a wire-reinforced flexible connector.

 Once connected, check the supply pressure at the pressure port     , to

the back of the appliance, in one of the ends of the gas inlet manifold.

 

Check the connection for leaks.

A

B

OPERATIONAL TESTS AND CHECKS:

Once connected, check that the burners operate correctly (hob and oven) and adjust as required.
CHECKING THE OPERATION OF THE HOB BURNERS:

 

• 

Check that the appliance is connected to the electrical power supply. The electrical ignition works 

if the appliance is connected to the electrical power supply.

• 

Check that the gas shut-off valve is open.

Multicooker

Chargrill

Electric fryer

Gas burners

Induction

Ceramic Hob

Plancha

Содержание LAG 010 UR

Страница 1: ...Hob top option GAS BRANDERS LAG 010 UR LAG 020 R LAG 024 R EN 10 2016 Multicooker Chargrill Electric fryer Gas burners Induction Ceramic Hob Plancha ...

Страница 2: ...2 burners of different size and power Voir B C D table 1 appendix 0 Controlled by a thermocouple safety valve Mounted in a dished recess stainless steel Z7CN 18 09 Electric push button ignition Accessories Two 1 2 enamelled cast iron pan supports One gas pipe with sockets Pressures and hourly consumption Appliance gas supplying can be switched please refer to rating plate and marking at the rear o...

Страница 3: ...ust be installed in a workmanlike manner in accordance with the instructions in this manual and locally applicable regulations This manual should be handed over to the user after installation EN 10 2016 Multicooker Chargrill Electric fryer Gas burners Induction Ceramic Hob Plancha ...

Страница 4: ... or whenever an existing shut off valve is replaced LPG butane propane Propane gas The installation must have a class 1 safety regulator Connect the appliance to the outlet of a 4 kg h regulator Recommended dual bottles to inlet of regulator for correct operation of the appliance during prolonged periods at full capacity Supply from 35 kg bottle or from tank is possible and recommended connection ...

Страница 5: ... correct operation of the burners hob and oven must be checked If required the height of the flame must be adjusted accordingly To do this the gas delivery rate to the burner must be adjusted by screwing in or out the valve adjustment screw located behind the control knob This adjustment is essential when changing the gas supply after having changed injectors refer to Section Change of gas WARNING...

Страница 6: ... is well covered by the flame and does not touch the burner The thermocouples and magnetic heads are clean The magnetic head is tightened correctly moderate torque PRIMARY AIR ADJUSTMENT The adjustment of the primary air air gas mixture is done by adjusting the air ring located in the base of the burner under the table The mixture is correct when the flame is stable with blue cones A soft flame wi...

Страница 7: ...erminals must be of such lengths as to ensure in the event of traction that the live cables become taut before the earth cable If the appliance is permanently connected to a fixed electrical installation this installation must be fitted with a suitable leakage current protection device If the appliance is connected with a cable fitted with a plug the socket must be accessible at all times 1 Remove...

Страница 8: ...lation Any change of voltage from that for which the appliance is set up must be carried out by a qualified installer WARRANTY The warranty is part of the sale contract For any warranty work please contact an authorized reseller This warranty does not cover damage due to faulty installation misuse or inadequate maintenance Multicooker Chargrill Electric fryer Gas burners Induction Ceramic Hob Plan...

Страница 9: ... the burners Before any cleaning work close the gas supply and or isolate from the mains electricities supply CLEANING AND MAINTENANCE WARNING Do not use a steam cleaner to clean the range Use Simultaneously press in and turn the burner dial anti clockwise to setting Press the ignition button while maintaining pressure on burner dial for about 20 seconds to ignite burner and initialise safety ther...

Страница 10: ......

Отзывы: