INSTALLER’S MANUAL
CHAMBERTIN – CHASSAGNE - FONTENAY
Page 11 of 47 – US –
Cabinet preparation
:
A
B
C
D
E
F
G
H
I
J
J1
K
mm 914 330 457 930 235
405
765
865
51
1110 1510
660
’’
36 13 18 36
5/8
9
1
/
4
15
15
/
16
30
1
/
8
34
1
/
16
2
43
11
/
16
59
7
/
16
26
Fig. 10
The range is a free standing unit. If the unit is to be placed next to cabinets, the clearances shown in Figure 10
are required.
The range cooktop surface must be no lower than the adjacent base cabinet countertop surface.
Min clearances to combustibles:
0’’ (0 mm) from rear (with spacer installed).
0’’ (0 mm) from sides
below
countertop surface height.
2’’ (51 mm) from sides
above
countertop surface height.
Cabinets 13’’ (330 mm) deep may be installed above the range at least 30’’ above the plane of the
cooking surface.
Use range only with factory supplied legs.
B
A
D
G
E
C
F
J = Chambertin
/Chassagne
J1 = Fontenay
I
I
H
K
Gas connection
on range
Electrical connection
on range
Place electrical and gas
stub-out in this area