11
damaged should be carefully checked to determine that it will operate properly and perform its intended function.
Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions that may
affect its operation.
A guard or other part that is damaged should be properly repaired or replaced by an authorized service center unless otherwise
indicated elsewhere in this Instruction Manual. Have defective pressure switches replaced by authorized service center.
Do not use compressor if switch does not turn it on and off.
16. HANDLE COMPRESSOR CORRECTLY
Operate the compressor according to the instructions provided
herein. Never allow the compressor to be operated by children,
individuals unfamiliar with its operation or unauthorized personnel.
17. KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY IN PLACE
Keep all screws, bolts, and plates tightly mounted.
Check their conditions periodically.
18. KEEP MOTOR AIR VENT CLEAN
The motor air vent must be kept clean so that air can freely flow at all times. Check for dust build-up frequently.
19. OPERATE COMPRESSOR AT THE RATED VOLTAGE
Operate the compressor at voltages specified on their nameplates. If using the compressor at a higher voltage than the rated voltage,
it will result in abnormally fast motor revolution and may damage the unit and burn out the motor.
20. NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR OPERATING ABNORMALLY
If the compressor appears to be operating unusually, making strange noises, or otherwise appears defective, stop using it immediately
and arrange for repairs by an authorized service center.
21. DO NOT WIPE PLASTIC PARTS WITH SOLVENT
Solvents such as gasoline, thinner, benzine, carbon tetrachloride, and alcohol may damage and crack plastic parts. Do not wipe them
with such solvents. Wipe plastic parts with a soft cloth lightly dampened with soapy water and dry thoroughly.
22. USE ONLY GENUINE REPLACEMENT PARTS
Replacement parts not original may void your warranty and can lead to malfunction and resulting injuries. Genuine parts are available
from your dealer.
23. DO NOT MODIFY THE COMPRESSOR
Do not modify the compressor. Always contact the authorized service center any repairs. Unauthorized modification may not only
impair the compressor performance but may also result in accident or injury to repair personnel who do not have the required
knowledge and technical expertise to perform the repair operations correctly.
24. TURN OFF THE PRESSURE SWITCH WHEN THE COMPRESSOR IS NOT USED
When the compressor is not used, turn the knob of the pressure switch OFF, disconnect it from the power source and open the drain
cock to discharge the compressed air from the air tank.
25. NEVER TOUCH HOT SURFACE
To reduce the risk of burns, do not touch tubes, heads, cylinder and motors.
26. DO NOT DIRECT AIR STREAM AT BODY
Risk of injury, do not direct air stream at persons or animals.
27. DRAIN TANK
Drain tank daily or after 4 hours of use.
Open drain fitting and tilt compressor to empty accumulated water.
28. DO NOT STOP COMPRESSOR BY PULLING OUT THE PLUG
Use the “AUTO/OFF” knob of pressure switch.
29. USE ONLY RECOMMENDED AIR HANDLING PARTS ACCEPTABLE FOR PRESSURE NOT LESS THAN 125 PSI (8.6 BAR)
Risk of bursting: use only recommended air handling parts acceptable for pressures not less than 125 psi (8.6 bar).
REPLACEMENT PARTS
When servicing use only identical replacement parts.
Repairs should be conducted only by authorized service center.
GROUNDING INSTRUCTIONS
This compressor should be grounded while in use to protect the operator from electric shock. The compressor is equipped with a
three-conductor cord and three-prong grounding type plug to fit the proper grounding type receptacle.
The green (or green and yellow) conductor in the cord is the grounding wire. Never connect the green (or green and yellow) wire to a
live terminal.
EXTENSION CORD
Use only three-extension cords that have three-prong grounding type plugs and three-pole receptacles that accept the compressor’s
plug.
Replace or repair damaged cord. Make sure your extension cord is in good condition. When using an extension cord, be sure to use
one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of
power and overheating.
Table shows the correct size to use depending on cord length and name plate ampere rating. If in doubt, use the next heavier gage. The
smaller the gage number, the heavier the cord.
For 0,75 CV/0.56 kW and voltage 220/230 V, the section of the extension cord must be 1.5mm².
WARNING
Avoid electrical shock hazard. Never use this compressor with a damaged or frayed electrical cord or extension cord. Inspect all
electrical cords regularly. Never use in near water or in any environment where electric shock is possible.