![LaboGene Fortuna 1200 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/labogene/fortuna-1200/fortuna-1200_instruction-manual_668005035.webp)
Instruction manual for Fortuna
12062017QA01
Item No. 700745
CopyRight © 2017
Page
35
of
49
10
Quality testing of the Fortuna cabinets
All Fortuna cabinets are adjusted and tested before leaving the factory. A factory check list and a
factory test report is issued for each cabinet and is, together with the HEPA filter test certificates and
an instruction manual, shipped with the cabinet.
10.1
Test terms and definitions
Nominal value
Default value as specified by LaboGene.
Measured value
Value measured at the location of the sterile cabinet.
Tolerance
Acceptable deviation from the nominal value.
Average value
The sum of the measuring values divided by the number of tests.
The average value is compared to the nominal value.
Set point
Acceptable operating value for the downflow air velocity.
Downflow air velocity
Velocity of the displacement airflow circulating through the working
chamber.
10.2
What is required by EN 12469 to be tested
Test
Factory
Installation
Service
Leak test of HEPA filters
Yes
Yes
Yes
Downflow air velocity and setting of alarms
Yes
Yes
Yes
Test of alarms
Yes
Yes
Yes
Light test
Yes
Yes
Airflow pattern test
Yes
Yes
Yes
Electrical test
Yes
Special tests not included as default
Particle counting in working chamber
Yes
UV light intensity
Yes
Sound test
Yes
10.3
The factory quality test of the Fortuna cabinets
The factory quality test of the cabinets is designed to ensure that the cabinet is functioning in
accordance with requirements and specification before being shipped to the customer.
10.4
The factory check list and factory test report
The factory check list and factory test report is designed for the Fortuna cabinets specifically. They
document all quality related activities performed during the production through testing and cleaning
when the cabinet is ready for packing and shipment.
A filled in and reviewed check list and test report is shipped with each cabinet.
10.5
Test equipment needed to perform installation tests and service tests
The test equipment needed to perform installation and service test are:
Содержание Fortuna 1200
Страница 38: ...12162017QA01 Item No 700745 CopyRight 2017 Page 38 of 49 12 Annex 1 Factory check list and factory test report...
Страница 39: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 39 of 49...
Страница 40: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 40 of 49...
Страница 41: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 41 of 49...
Страница 42: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 42 of 49...
Страница 43: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 43 of 49...
Страница 44: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 44 of 49...
Страница 45: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 45 of 49...
Страница 46: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 46 of 49...