LaboGene Fortuna 1200 Скачать руководство пользователя страница 13

Instruction manual for Fortuna 

 

 

12062017QA01 

Item No. 700745 

CopyRight © 2017

 

Page 

13

 of 

49

 

 

Start-up of the Fortuna cabinets 

 

Caution

 

Correct assembly and installation is essential for proper start-up and operation of the 
Fortuna cabinets. 

5.1 

Preparation 

 

Caution

 

The installations site for the unit must be draught-free and should be selected so that  
frequent passing of people in front of the work opening is avoided. 

 
1. 

Adjust the levelling screws to assure that the table top is in horizontal position and levelled. 
 

2. 

Valves for gases or vacuum are installed in the side windows. A qualified technician must 
make the connections for the supply. 

 
When the cabinet has been installed: 
 
1. 

Check that the front window is in the correct position, i.e. parallel to the front shield. 
 

2. 

Never lift the front window manually - this will cause window to mall function. 
 

3. 

Check that the window slides from top to bottom without any irregular sound. 
 

4. 

If the window does not move when the UP or DOWN button is pressed, authorized service  
personnel must be called to correct the fault. 
 

5. 

Always  keep  hands  and  arms  away  from the  working  chamber  when  activating  the front 
window. 

5.2 

Connections 

Required fusing: Circuit breaker 10 A (13 A) or fuse T 10 A (T 13 A). 
 
In addition, the applicable safety requirements of the local power Supply Company shall apply. 
 

 

Caution

 

If an automatic relay for disconnection of power in case of electric fault is needed, it 
must be installed in the supply, as it is not built-in. 

 

 

Caution

 

Before connecting the power supply it must be checked that the mains specifications  
correspond to those stated on the type plate. 

 

 

Caution

 

The  safety  cabinet  is  provided  with  a  flexible  power  cord.  The  connection  may  be  
installed hard-wired or by means of a wall outlet with protective ground. 

 

Содержание Fortuna 1200

Страница 1: ...12162017QA01 Item No 700745 CopyRight 2017 Page 1 of 49 INSTRUCTION MANUAL Fortuna 900 1200 1500 1800 Clean Bench...

Страница 2: ...nger of medium or minor injuries or physical damage This document is the original instruction manual in accordance with the current Machinery Directive This document is the reference for any translati...

Страница 3: ...12 4 6 Connecting utilities to the Fortuna cabinets 12 5 Start up of the Fortuna cabinets 13 5 1 Preparation 13 5 2 Connections 13 5 3 Assemble the stand for the Fortuna cabinets 14 5 4 Levelling of...

Страница 4: ...27 8 3 Optional UV lights 28 8 4 Replacement of fuses 28 8 5 Replacement of laminator 29 8 6 Replacements and repairs 29 8 7 Disposal of cabinet 29 9 Specifications 30 9 1 Spare parts 34 10 Quality t...

Страница 5: ...factory settings The EN 12469 standard requires that the downflow air velocity is in the interval 0 25 m s 0 50 m s The LaboGene default downflow setting is 0 32 m s for 350 mm work opening with a max...

Страница 6: ...e nameplate data Caution The proper function and safety of the cabinet is only secured if personnel authorized by us perform the required tests maintenance and repair work Please also refer to section...

Страница 7: ...ing of downflow air velocity guarantees that product protection remains uncompromised Airflow monitoring using build in flow sensor determine the velocity of the airflow in the work chamber As soon as...

Страница 8: ...ired for individual requirements See Service menu When switching to reduced velocity the low flow alarm is activated and the light in the cabinet is turned off to indicate not safe conditions 3 Button...

Страница 9: ...w button 9 On start up after power disconnect or after power failure the above alarm will be active Press the blue ENTER button to clear the alarm The main screen showing the time and date The display...

Страница 10: ...ng chamber The standard LaboGene control system is prepared for full control of safety and timing for the use of UV light see section UV light option for operation and build in safety measures Remembe...

Страница 11: ...must be rated for twice the cabinet weight Adequate room height For cabinets which are not connected to an exhaust system the distance between the exhaust air opening on the cabinet and the room ceili...

Страница 12: ...f moving is warranted both the Fortuna can be lifted and moved using a low lifter on 1500 and 1800 models use one from each side Be aware that the cabinets are top heavy Stabilize cabinet during the m...

Страница 13: ...ront window manually this will cause window to mall function 3 Check that the window slides from top to bottom without any irregular sound 4 If the window does not move when the UP or DOWN button is p...

Страница 14: ...and Fortuna 1800 75 80 cm 9 001 040 014 Stand Fortuna 900 90 95 cm 9 001 030 011 Stand Fortuna 1200 90 95cm 9 001 030 012 Stand Fortuna 1500 90 95cm 9 001 030 013 Stand Fortuna 1800 90 95 cm 9 001 030...

Страница 15: ...net General functionality is checked ad Hoc To ensure optimal function and performance of the cabinet the parameter values found in the Factory test report must be used as close as possible An install...

Страница 16: ...be adjusted to any level desired for individual requirements See Service menu Button 3 with red light to silence the acoustic alarm Button 4 with blue light for normal light ON OFF Button 5 with yello...

Страница 17: ...Auto start auto stop Here it is possible to select Monday to Friday whole week or only a single day when the cabinet should start up in full speed and after how long it should wait until it switches o...

Страница 18: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 18 of 49 6 1 Overview of the user menu...

Страница 19: ...tantly supervised so that any deviation from safe conditions or any fault in the supervision system will be indicated immediately Safe conditions are indicated by a green LED light in the button for f...

Страница 20: ...mode if there is an alarm the light will turn off automatically and will only be turned on again when all alarms have been deactivated 6 6 Start up of the Mars and Mars Pro cabinets Turn on the cabine...

Страница 21: ...nly be activated when the window is completely closed The light is switched off in the cabinet during the UV disinfection period The UV period is controlled by a timer integrated in the control system...

Страница 22: ...front window is positioned in working position and kept in that position during the entire work process Necessary appliances for use during work must be placed within easy reach Secure the appropriate...

Страница 23: ...he work chamber remove fluids if any from the trough and dry it Disinfect if required Leave the cabinet fan in operation for about another 10 minutes Close the front window to its lowest position 6 11...

Страница 24: ...re for this process Decontamination using formaldehyde can be performed if a sterile working chamber is required for the work procedure This decontamination procedure or a similar one is required befo...

Страница 25: ...ring pads or steel wool If the coated surfaces do become dull streaked smeared or marred in some other way there is no known method to restore the finish 7 3 Disinfection of working chamber 1 Remove a...

Страница 26: ...on Before repair work is carried out inside the contaminated and or infected cabinet and prior to filter replacement and upon change of location proper cleaning and disinfecting by the operator is req...

Страница 27: ...onditions of the cabinet Optional test can be performed on request Particle test in the working chamber to determine the air quality Sound level test Light intensity test normal light Light intensity...

Страница 28: ...se lamps from the fixtures by rotating it 90 Install the new UV lamp performing the inverse operation Note Use gloves when manipulating a germicidal UV lamp to prevent leaving hand prints that reduce...

Страница 29: ...the replacement laminator and mount the fixing screws again Product name Catalogue No Laminator Fortuna 900 9 000 071 001 Laminator Fortuna 1200 9 000 071 002 Laminator Fortuna 1500 9 000 071 003 Lam...

Страница 30: ...at least Class H14 Table top and trough material AISI 304 stainless steel Table top max total load kg 100 Side glass material 5 mm hardened glass Front glass material 6 mm laminated safety glass Cabin...

Страница 31: ...m hardened glass Front glass material 6 mm laminated safety glass Cabinet and back wall material colour Polyester coated steel RAL 9016 Dimensions External dimensions with adjustable Stand Standard Dx...

Страница 32: ...hardened glass Front glass material 6 mm laminated safety glass Cabinet and back wall material colour Polyester coated steel RAL 9016 Dimensions External dimensions with adjustable Stand Standard DxW...

Страница 33: ...hardened glass Front glass material 6 mm laminated safety glass Cabinet and back wall material colour Polyester coated steel RAL 9016 Dimensions External dimensions with adjustable Stand Standard DxW...

Страница 34: ...0 9 000 050 008 Light ballast for Fortuna 1500 and 1800 9 000 050 009 Window motor for Fortuna 9 000 050 112 Display board Fortuna 9 000 050 011 Motor board Fortuna 9 000 050 010 UV light ballast Fort...

Страница 35: ...be tested Test Factory Installation Service Leak test of HEPA filters Yes Yes Yes Downflow air velocity and setting of alarms Yes Yes Yes Test of alarms Yes Yes Yes Light test Yes Yes Airflow pattern...

Страница 36: ...led the operator doing the work and the environment in the surrounding room All tests should be done by authorized test technician approved by LaboGene 11 Options for Fortuna cabinets A number of opti...

Страница 37: ...onal valves for utilities are delivered make sure that local rules and regulations are complied with during installation and use It is generally recommended to use an authorized technician for this ki...

Страница 38: ...12162017QA01 Item No 700745 CopyRight 2017 Page 38 of 49 12 Annex 1 Factory check list and factory test report...

Страница 39: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 39 of 49...

Страница 40: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 40 of 49...

Страница 41: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 41 of 49...

Страница 42: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 42 of 49...

Страница 43: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 43 of 49...

Страница 44: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 44 of 49...

Страница 45: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 45 of 49...

Страница 46: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 46 of 49...

Страница 47: ...o 700745 CopyRight 2017 Page 47 of 49 13 Annex 2 Service log book Type Product name Serial no Supplier Service interval Location Service repair Fault occurred on Notified date Repaired date Remark fau...

Страница 48: ...es from all dangers We therefore kindly ask you to copy and complete this statement before work is commenced Subject Service report no Service agreement no The undersigned hereby declares that the abo...

Страница 49: ...Instruction manual for Fortuna 12062017QA01 Item No 700745 CopyRight 2017 Page 49 of 49 15 Annex 4 Declaration of comformity Fortuna...

Отзывы: