Lab.gruppen Tesira D 120:4T Скачать руководство пользователя страница 7

6. Feature summary 

D SERIES Tesira Quick Start Guide  rev 1.2.0

7

    

6. Feature summary 

•  Four channels with three levels of total available frame power output: 20000 W, 12000 W and 8000 W
•  Rational Power Management (RPM)

•  True flexibility in allocating power output across each channel to match requirement, for more efficient use 

   

of amplifier inventory

•  Any channel is capable of delivering up to 5000 W power output, from total available power in each frame

•  Dedicated on-board surveillance and load monitoring for voice alarm applications
•  Advanced universal power supply

•  Regulated Switch-Mode Power Supply (R.SMPS™) maintains stability through fluctuations in mains voltage
•  Best-in-class Power Factor Correction (PFC)
•  Current Draw Modeling (CDM™) reduces peak mains draw
•  Breaker Emulation Limiter (BEL™) responds to available mains distribution
•  Under-Voltage Limiting (UVL™) allows continued operation through mains voltage drop

•  CAFÉ (Configuring Amplifiers For the Environment) software incorporates ESP™ (Equipment Specification  
  Predictor) to assist in design, equipment specification and commissioning
•  Features controlled by on-board DSP

•  Input Gain (Sensitivity) - Input gain (sensitivity) is set in the digital domain and controlled via CAFÉ software
•  ISVPL™ - The Inter-Sample Voltage Peak Limiter (ISVPL) tailors each channel’s power output to the  

   

characteristics of the connected load. 

•  Load Verification & Performance Monitoring - A comprehensive set of proprietary DSP-based tools  

   

enables load verification and real-time performance monitoring. 

6.1. Features Unique to Tesira® DSP and Networking Environment 

•  Developed and supported by Biamp Systems
•  D Series Tesira models fully integrated as high-power output devices
•  Channel processing control of Mute, Level and Signal Invert
•  Four input channels via Ethernet-based Audio Video Bridging (AVB) network
•  Optional four channels of analog input for local input into system or failover
•  Power state management with configurable Auto Power Down for ultra-low power draw in sleep state
•  GPIO port for further system integration
•  Creation of customized control programs in Biamp Canvas software

Содержание Tesira D 120:4T

Страница 1: ...DSERIES High Powerinstallationplatform Rev 1 2 0 Quick Start Guide Tesira Variants D 200 4T Ta D 120 4T Ta D 80 4T Ta Incorporating technologies from Item no QSG DSERIES TESIRA...

Страница 2: ...e risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases...

Страница 3: ...s for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rule...

Страница 4: ...3 4 1 Mains connection grounding 3 3 4 2 Speaker output hazard on amplifiers 3 3 4 3 Radio interference 3 3 4 4 Speaker damage 3 3 4 5 Maintenance 3 5 Introduction 6 5 1 Welcome 6 5 2 D Series Two ver...

Страница 5: ...12 Signal flow and processing 15 13 Quick Start Tutorial 16 13 1 Software installation and firmware update 16 13 1 1 Tesira Software 16 13 1 2 Firmware update 16 13 2 Network setup 17 13 3 System setu...

Страница 6: ...to ensure familiarity with the various configuration and control options Thank you again for placing your confidence in Lab gruppen products 5 2 DSeries Twoversionsavailable D Series is an advanced hi...

Страница 7: ...nment software incorporates ESP Equipment Specification Predictor to assist in design equipment specification and commissioning Features controlled by on board DSP Input Gain Sensitivity Input gain se...

Страница 8: ...dust filter assembly NOTE Depending on the model the connector kit might include more connectors than applicable for the product you have Select those connectors required for your unit and applicatio...

Страница 9: ...s to the amplifier with magnets Hold the front grille with your fingers in each of the side cutouts and slide it gently into place straight from the front NOTE Always ensure the dust filters behind th...

Страница 10: ...ich has already been heated by the D Series devices The D Series device is equipped with a sophisticated temperature sensing system which protects it from any overheating which may occur as a result o...

Страница 11: ...3 phase delta 208V 208V 2 0 8 V 2 0 8 V L1 L2 L3 Connecting the amplifier in a split phase configuration In two phase split phase configuration there are two phases separated by 180 degrees Connectin...

Страница 12: ...h of the button toggles the amplifier between ON and SLEEP state Channel Status and Control 7 LOAD LED for load related status indication 8 AMP LED for amplifier related status indication 9 SIGNAL LED...

Страница 13: ...evice configured and ready to participate in a system Device is ready and waiting to receive a configuration Device is not ready to receive a configuration Power Mains power not available Device is ON...

Страница 14: ...Ethernet AVB digital audio network 3 Serial control port on a DB 9 for integration control 4 Terminal block connector for Logis I O 4 pins of GPIO and a ground 5 Analog inputs on Tesira Analog versio...

Страница 15: ...k in the Tesira output section 4 Level block in the Tesira output section 5 Invert block in the Tesira output section 6 Amplifier gain Digitally implemented for exact control and management of gain st...

Страница 16: ...ervers Update Tesira server firmware 1 Download Tesira Firmware from biamp com www biamp com products tesira downloads aspx Locate the Software and Firmware section and download the latest version of...

Страница 17: ...t to obtain IP addresses automatically The Tesira device will receive an IP address automatically from a DHCP server if present or assign itself an IP address in the Link local range 169 254 1 0 throu...

Страница 18: ...nd a speaker Create Tesira system configuration 1 Open Tesira software 2 Select Labgruppen amplifier from the Object bar I O Blocks 3 Click somewhere in the layout window to place an amplifier in the...

Страница 19: ...nd click the reset device button to the left 2 Enter the Equipment table via System equipment table 3 For both the server and the amplifier click the cell in the serial number or host name column and...

Страница 20: ...s and highlights the current amplifier NOTE If a firewall is installed on your computer you must give the CAF application permissions to talk to the amplifiers Within CAF you can configure basic ampli...

Страница 21: ...ITCH Mains glitch missing cycles was detected on the mains inlet Check mains distribution connection Warning Temperature warning power supply TEMP WARN PSU Power supply temperature approaching critica...

Страница 22: ...below thresholds Check load or calibration Warning Speaker damaged SPKR DAMAGED One LoadPilot tone is above or below threshold Check load or calibration Fault No load NO LOAD At least one LoadPilot t...

Страница 23: ...ain Digital configurable amplifier gain 22 44 dB Pilot tone generation and analysis LoadPilot Load impedance analysis Yes Temperature control Regulated fans and show must go on limitation ATL PTL Audi...

Страница 24: ...tional device software select functionality Mains Power Nominal voltage 100 240 V AC 50 60 Hz Operating voltage 70 265 V AC 45 66 Hz Mains wall plug Selectable on order CEE 7 7 Schuko 230 V 16 A NEMA...

Страница 25: ...d by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequential damage...

Страница 26: ...zation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect...

Страница 27: ...27 DSERIESTesiraQuickStartGuide rev1 2 0 Notes Notes...

Страница 28: ...CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB Tesira is a trademark of Biamp Systems All other trademarks remain the property of...

Отзывы: