14. Faults and warnings
22
D SERIES Tesira Quick Start Guide rev 1.2.0
Category/Type
Name
On screen text
Description
Action
Fault
Mains voltage above
270 V
MAINS > 270 V
Power supply detects mains voltage
above operation voltage. Protective shut
down, auto restart attempt
Check mains distribution/
connection
Fault
Mains voltage below
65 V
MAINS < 65 V
Power supply detects mains voltage
below operation voltage. Protective shut
down, auto restart attempt
Check mains distribution/
connection
Fault
Power supply fault
PSU FAULT
Internal power supply fault
Check mains distribution/
connection.Restart device;
if not cleared it needs
servicing
Fault
Check mains
CHECK MAINS
Power supply detects unstable mains
supply. Protective shut down,
auto restart attempt
Check mains distribution/
connection
Fault
Power supply power protect
PSU POWER PROT
Too high output power for too low mains
supply voltage. Protective shut down,
auto restart attempt.
Improve mains supply
voltage or reduce output
power
LOAD
Warning
Under speaker count
UNDER SPKR CNT
Both LoadPilot tones above thresholds
Check load or calibration
Warning
Speaker short
SPKR SHORT
Both LoadPilot tones below thresholds
Check load or calibration
Warning
Speaker damaged
SPKR DAMAGED
One LoadPilot tone is above or
below threshold
Check load or calibration
Fault
No load
NO LOAD
At least one LoadPilot tone above
measurable area of significantly
above thresholds
Check load or calibration
Fault
Short circuit
SHORT CIRCUIT
LoadPilot or full frequency analysis
below short threshold or
hardware short protection
Check load or calibration
AMP
Warning
Temp warning amplifier channel
TEMP WARN
Amplifier channel is
approaching critical
Improve cooling or reduce
output power to avoid
temperature becoming
critical
Fault
Temp Fault amplifier channel
TEMP FAULT
Amplifier channel has reached critical
temperature and has shut off for
protective reasons
Automatically unmutes
when cooled down
Fault
Service channel
SERVICE CH.
Amplifier channel is damaged
Restart device; if not
cleared needs servicing
SIGNAL
Clip
Current average limiter
CAL ACTIVE
Average current on amplifier above
safe operating level
Reduce output current
to avoid limiting
Clip
Current clip
CURRENT CLIP
Amplifier channel reached
current limit
Reduce output power
to avoid limiting
Fault
Very high frequency fault
VHF FAULT
Amplifier channel protection
Check input signal
Clip
Voltage clip
VOLTAGE CLIP
Amplifier reached voltage limit
Reduce output power
to avoid limiting