Lab.gruppen PLM+ Series Скачать руководство пользователя страница 35

14. Faults and warnings 

PLM+ SERIES  Quick Start Guide  rev 3.0.2

35

    

Category/Type

Name

On screen text

Description

Action

PSU

Warning

Under Voltage Limit

UVL ACTIVE

The Under Voltage limiter is active as the

mains supply is approaching the lower 

end of the device´s operational voltage. 

Output power is decreased to ensure 

mains distribution does not collapse

Increase mains distribution 

stiffness or reduce output 

power to avoid limiting

Warning

Power Average Limit

PAL ACTIVE

 

to average power or mains current 

draw is above safe operating levels

Reduce output power 

to avoid limiting

Warning

Breaker Emulation Limit

BEL ACTIVE

Power supply is reducing mains current 

Improve mains distribution 

and update BEL 

output power to avoid 

limiting

Warning

Mains supply glitch

MAINS GLITCH

Mains glitch (missing cycles) was 

detected on the mains inlet

Check mains distribution/

connection

 

Fault

Need service

NEED SERVICE:1-8

Power supply internal error

Restart device; if not 

cleared it needs service

Fault

Mains voltage above 

400 volt peak

MAINS>400 VPK

Power supply detects mains voltage 

above 400 volt peak. Protective shut 

down, auto restart attempt

Check mains distribution/

connection

Fault

Mains voltage above 

270 V

MAINS>270 V

Power supply detects mains voltage 

above operation voltage. Protective 

shut down, auto restart attempt

Check mains distribution/

connection

Fault

Mains voltage below 

65 V

Mains<65 V

Power supply detects mains voltage 

below operation voltage. Protective 

shut down, auto restart attempt

Check mains distribution/

connection

Fault

Power supply fault

PSU FAULT

Internal power supply fault

Check mains distribution/

connection. Restart 

device; if not cleared 

it needs service

Fault

Check mains

CHECK MAINS

Power supply detects unstable mains 

supply. Protective shut down, auto 

restart attempt

Check mains distribution/

connection

Fault

Power supply power protect

PSU POWER PROT

Too high output power for too low mains 

supply voltage. Protective shut down, 

auto restart attempt

Improve mains supply 

voltage or reduce 

output power

LOAD

Warning

Speaker short

SPKR SHORT

Both LoadPilot tones below thresholds

Check load or calibration

Warning

Speaker damaged

SPKR DAMAGED

One LoadPilot tone is above 

or below threshold

Check load or calibration

Warning

Under speaker count

UNDER SPKR CNT

Both LoadPilot tones above thresholds 

or LoadSmart detected fewer 

speakers than expected

Check load and 

cabling alibration

Содержание PLM+ Series

Страница 1: ...PLM SERIES PoweredLoudspeakerManagement System Rev 3 0 2 Quick Start Guide PLM 20K44 PLM 12K44 PLM 5K44 Item no QSG PLM SERIES Incorporating technologies from...

Страница 2: ......

Страница 3: ...fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases are place...

Страница 4: ...for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules...

Страница 5: ...5 PLM SERIES QuickStartGuide rev3 0 2 EN55032 Class A EN55103 1 E4 E4 2014 30 EU 2006 95 EC EMC...

Страница 6: ...6 PLM SERIES QuickStartGuide rev3 0 2...

Страница 7: ...lectrique n enlevez pas les couvercles Il n y a pas des parties serviceable l int rieur tous reparations doit etre faire par personnel quali seulment EMC European Electro Magnetic Com patibility EU EM...

Страница 8: ...r l appareil Fran ais Cet appareil doit tre raccord une prise secteur avec terre de protection Fran ais Lorsque la prise du r seau d alimentation est utilis s comme dispositif de d connexion ce dispos...

Страница 9: ...du secteur 16 AVERTISSEMENT pour r duire le risque d incendie et de choc lectrique n exposez pas cet appareil la pluie ni l humidit 17 N exposez pas cet appareil au ruissellement ni aux claboussures...

Страница 10: ...tels que les radior cepteurs L absence d interf rences n est toutefois pas garantie pour une installation donn e Si cet quipement provoque des interf rences nuisibles la r ception de la radio ou de la...

Страница 11: ...eines Feuers oder eines elektrischen Schlages zu verringern darf dieses Ger t nicht Regen oder starker Feuchtigkeit ausgesetzt werden 17 Setzen Sie dieses Ger t nicht tropfendem Wasser oder Spritzwas...

Страница 12: ...Communications Commission FCC f r digitale Ger te der Klasse B nach Abschnitt 15 Diese Einschr nkungen sollen angemessenen Schutz vor sch dlichen St rungen durch elektrische Ger te gew hrleisten Dies...

Страница 13: ...arato quede expuesto a la lluvia o la humedad 17 No permita que este aparato quede expuesto a salpicaduras de ning n tipo y no coloque objetos que contengan l quidos como jarrones encima de este apara...

Страница 14: ...ropea de compatibilidad electromagn tica EMC Tambi n se ha verificado que este aparato cumple con los l mites establecidos para dispositivos digitales de clase A de acuerdo a lo expuesto en el apartad...

Страница 15: ...nsibility 4 3 4 1 Mains connection grounding 4 3 4 2 Speaker output hazard on amplifiers 4 3 4 3 Radio interference 4 3 4 4 Speaker damage 4 3 4 5 Maintenance 4 5 Introduction 17 5 1 Welcome 17 6 Feat...

Страница 16: ...setup 27 13 1 1 Network connections topology 27 13 1 2 Network configuration 27 13 2 Software installation and firmware update 28 13 2 1 Lake Controller software suite 28 13 2 2 CAF software 28 13 2 3...

Страница 17: ...Management RPM True flexibility in allocating power output across each channel to match requirement for more efficient use of amplifier inventory Any channel is capable of delivering up to 5900 W PLM5...

Страница 18: ...cking Carefully open the shipping carton and check for any damage to the device or the supplied accessories Every Lab gruppen product is tested and inspected before leaving the factory and should arri...

Страница 19: ...rack 7 2 1 RearMounting Two rear support brackets along with associated mounting hardware are included with the PLM device It is strongly recommended that these are used wherever possible Fit the bra...

Страница 20: ...r more PLM devices in a rack with other fan cooled equipment confirm that all other equipment also uses front to rear airflow for cooling If this precaution is not observed there is a risk of overheat...

Страница 21: ...plifiers nominal voltage range Connecting the amplifier in three phase delta configuration In three phase configuration where the phases are 120 degrees apart one can connect three balanced loads in a...

Страница 22: ...10 2 1 1 Handles Handles should be used when carrying and when fitting into or removing from a rack Ensure that rack doors or covers have sufficient depth to clear the handles 2 Dust Filters Two dust...

Страница 23: ...er view The four LEDs display mute status red mute green unmute as well as fault and warning indications Global faults and warnings are indicated by simultaneous illumination of all four LEDs Please r...

Страница 24: ...connector options Both options allow for Bridge Mode operation PLM20K44 and PLM12K44 only which is activated in the Lake Controller software Please refer to the Lake Controller Operation Manual for mo...

Страница 25: ...nical reference of the Ethernet Port please refer to the full PLM Series Operation Manual Additional information is also available in the Lake Network Configuration Guide Note Additional processor con...

Страница 26: ...ng ISVPL limiter RPM and load monitoring 5 Power Amplifier INPUTS Dante Receivers 1 8 AES 1 4 Analog 1 4 OUTPUTS Dante 1 8 no mutes AES Analog pass through to Dante Input Routers 1 4 WITH INPUT MUTES...

Страница 27: ...io along with control data Note If using Dante audio in the network the audio traffic needs to be filtered from reaching the wireless links 13 1 2 Networkcon guration Frames are configured by default...

Страница 28: ...hrough a wired network 2 Launch the Lake firmware update utility LakeUpdate exe 3 Select the appropriate product range 4 If more than one network adapter is enabled a prompt will appear requiring sele...

Страница 29: ...e menu bar at the bottom of the screen to access the Module Menu and scroll bar 6 On the Module scroll bar the frame is represented with a frame containing four discs These are labeled A B C and D eac...

Страница 30: ...NFIG screen displays a block diagram for the Modules Tapping the different blue blocks will access the configuration screens for Input mixer Levels Input EQ Delay and Output EQ Crossover respectively...

Страница 31: ...the Events and Control dialog with the return button and return to the main area by tapping the I O Config EXIT button Levels Control Drag sliders and tap mute buttons for module input and output cha...

Страница 32: ...ms modules can be placed in groups Groups menu from the MAIN page for control of multiple units 13 4 RationalPowerManagement Rational Power Management RPM is a unique Lab gruppen feature that allows f...

Страница 33: ...are allows users to create an advanced custom power allocation scheme Switching to Custom mode disables the Automatic mode When RPM is active an RPM icon will be displayed next to the Actual ISVPL val...

Страница 34: ...toring Restart device if not cleared it needs service Fault A D converter power supply fault A D PSU FAULT Voltage supply to the analog input converters faulty Restart device if not cleared it needs s...

Страница 35: ...hut down auto restart attempt Check mains distribution connection Fault Mains voltage above 270 V MAINS 270 V Power supply detects mains voltage above operation voltage Protective shut down auto resta...

Страница 36: ...own Fault Service channel SERVICE CH Restart device if not cleared it needs service Fault Very high frequency fault VHF FAULT Check input signal or reduce output With a maximum of 12 dB of gain reduct...

Страница 37: ...rm with digital input THD N 20 Hz 20 kHz for 1 W THD N at 1 kHz and 1 dB below clipping Dynamic range Channel separation Crosstalk at 1 kHz Frequency response 1 W into 8 ohm 20 Hz 20 kHz Internal samp...

Страница 38: ...o N C A V 5 6 2 0 7 e g a t l o v g n i t a r e p O g u l p l l a w s n i a M NEMA L5 30 Twist lock 125 V 30 A and CEE 7 7 Schuko 230 V 16 A NEMA L5 30 Twist lock 125 V 30 A and CEE 7 7 Schuko 230 V 1...

Страница 39: ...not covered by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequent...

Страница 40: ...zation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect...

Страница 41: ...PLM SERIES QuickStartGuide rev3 0 2 41 Notes Notes...

Страница 42: ...42 PLM SERIES QuickStartGuide rev3 0 2 Notes Notes...

Страница 43: ...specification is subject to change RPM R SMPS PFC CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB All other trademarks remain the...

Отзывы: