8. Cooling and fan operation
20
PLM+ SERIES Quick Start Guide rev 3.0.2
8. Cooling and fan operation
PLM+ devices use a forced-air cooling system with air
fl
ow from front to rear, allowing high continuous power
levels without thermal problems. To facilitate maximum air
fl
ow, ensure that no objects such as rack doors or
lids are placed at the front or rear of the rack. Never attempt to reverse the air
fl
ow. Make sure an adequate
air supply is provided in front of the PLM+ device, and that the rear of the device has suf
fi
cient space to allow
air to escape. It is recommended to keep the ambient temperature around the device as cool as possible. An
increased temperature can have a signi
fi
cant negative impact on the expected lifetime on the components
inside the PLM+ Series device.
Note: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation.
Leaving gaps in between items of equipment degrades the effectiveness of forced-air cooling.
If installing one or more PLM+ devices in a rack with other fan-cooled equipment, con
fi
rm that all other
equipment also uses front-to-rear air
fl
ow for cooling. If this precaution is not observed, there is a risk of
overheating, as units with the reverse air
fl
ow will be drawing in air which has already been heated by the
PLM+ Series devices.
The PLM+ device is equipped with a sophisticated temperature sensing system which protects it from any
overheating which may occur as a result of inadequate ventilation.
9. Operating voltage
PLM+ Series has a universal power supply and its mains nominal and operating voltages are speci
fi
ed in the
Technical Speci
fi
cations (see section 15). PLM+ Series can be ordered with a variety of mains plugs. If the mains
plug (AC plug)
fi
tted to the mains cable (AC cord) is not appropriate for your country it can be removed and a
locally-sourced one
fi
tted instead. If you are not 100% con
fi
dent of your competence to replace the mains plug (AC
plug), the task should be carried out by quali
fi
ed personnel.
Note: In-rush current is controlled and limited during the soft-start sequence. This enables multiple
PLM+ Series Devices on the same AC mains circuit to be turned on simultaneously.