14. Faults and warnings 

24    

PLM+ SERIES  Quick Start Guide  rev 1.0.0

Category/Type

Name

On screen text

Description

Action

PSU

Warning

Under Voltage Limit

UVL ACTIVE

The Under Voltage limiter is active as the

mains supply is approaching the lower 

end of the device´s operational voltage. 

Output power is decreased to ensure 

mains distribution does not collapse

Increase mains distribution 

stiffness or reduce output 

power to avoid limiting

Warning

Power Average Limit

PAL ACTIVE

Amplifier is reducing output power due 

to average power or mains current 

draw is above safe operating levels

Reduce output power 

to avoid limiting

Warning

Breaker Emulation Limit

BEL ACTIVE

Power supply is reducing mains current 

draw to stay within BEL configured 

nominal current and profile

Improve mains distribution 

and update BEL 

configuration or reduce 

output power to avoid 

limiting

Warning

Mains supply glitch

MAINS GLITCH

Mains glitch (missing cycles) was 

detected on the mains inlet

Check mains distribution/

connection

Warning

Upgrade power 

supply firmware

UPGRADE PSU

Power supply firmware version not 

compatible with amplifier

Upgrade amplifier 

firmware

Fault

Need service

NEED SERVICE:1-8

Power supply internal error

Restart device; if not 

cleared it needs service

Fault

Mains voltage above 

400 volt peak

MAINS>400 VPK

Power supply detects mains voltage 

above 400 volt peak. Protective shut 

down, auto restart attempt

Check mains distribution/

connection

Fault

Mains voltage above 

270 V

MAINS>270 V

Power supply detects mains voltage 

above operation voltage. Protective 

shut down, auto restart attempt

Check mains distribution/

connection

Fault

Mains voltage below 

65 V

Mains<65 V

Power supply detects mains voltage 

below operation voltage. Protective 

shut down, auto restart attempt

Check mains distribution/

connection

Fault

Power supply fault

PSU FAULT

Internal power supply fault

Check mains distribution/

connection. Restart 

device; if not cleared 

it needs service

Fault

Check mains

CHECK MAINS

Power supply detects unstable mains 

supply. Protective shut down, auto 

restart attempt

Check mains distribution/

connection

Fault

Power supply power protect

PSU POWER PROT

Too high output power for too low mains 

supply voltage. Protective shut down, 

auto restart attempt

Improve mains supply 

voltage or reduce 

output power

LOAD

Warning

Speaker short

SPKR SHORT

Both LoadPilot tones below thresholds

Check load or calibration

Warning

Speaker damaged

SPKR DAMAGED

One LoadPilot tone is above 

or below threshold

Check load or calibration

Warning

Under speaker count

UNDER SPKR CNT

Both LoadPilot tones above thresholds 

or LoadSmart detected fewer 

speakers than expected

Check load and 

cabling alibration

Содержание PLM 12K44

Страница 1: ...PLM SERIES PoweredLouspeakerManagement System Rev 1 0 0 Quick Start Guide PLM 20K44 PLM 12K44 Item no QSG PLM SERIES Incorporating technologies from...

Страница 2: ...risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases a...

Страница 3: ...for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules...

Страница 4: ...responsibility 3 3 4 1 Mains connection grounding 3 3 4 2 Speaker output hazard on amplifiers 3 3 4 3 Radio interference 3 3 4 4 Speaker damage 3 3 4 5 Maintenance 3 5 Introduction 6 5 1 Welcome 6 6 F...

Страница 5: ...etup 16 13 1 1 Network connections topology 16 13 1 2 Network configuration 16 13 2 Software installation and firmware update 17 13 2 1 Lake Controller software suite 17 13 2 2 CAF software 17 13 2 3...

Страница 6: ...l Power Management RPM True flexibility in allocating power output across each channel to match requirement for more efficient use of amplifier inventory Any channel is capable of delivering up to 590...

Страница 7: ...ddleware 7 Installation 7 1 Unpacking Carefully open the shipping carton and check for any damage to the device or the supplied accessories Every Lab gruppen product is tested and inspected before lea...

Страница 8: ...rack 7 2 1 RearMounting Two rear support brackets along with associated mounting hardware are included with the PLM device It is strongly recommended that these are used wherever possible Fit the bra...

Страница 9: ...r more PLM devices in a rack with other fan cooled equipment confirm that all other equipment also uses front to rear airflow for cooling If this precaution is not observed there is a risk of overheat...

Страница 10: ...plifiers nominal voltage range Connecting the amplifier in three phase delta configuration In three phase configuration where the phases are 120 degrees apart one can connect three balanced loads in a...

Страница 11: ...10 2 1 1 Handles Handles should be used when carrying and when fitting into or removing from a rack Ensure that rack doors or covers have sufficient depth to clear the handles 2 Dust Filters Two dust...

Страница 12: ...er view The four LEDs display mute status red mute green unmute as well as fault and warning indications Global faults and warnings are indicated by simultaneous illumination of all four LEDs Please r...

Страница 13: ...3 Inputs Two latching XLR 3F connectors accept four channels of AES3 digital audio Input impedance is 110 ohms ensure that 110 ohm digital audio cables are used Output Connectors Your device will be e...

Страница 14: ...iguration is required for a dual redundant network setup See the Lake Controller Operation Manual for further details Note Do not create a closed loop when configuring multiple devices in an Ethernet...

Страница 15: ...ing ISVPL limiter RPM and load monitoring 5 Power Amplifier INPUTS Dante Receivers 1 8 AES 1 4 Analog 1 4 OUTPUTS Dante 1 8 no mutes AES Analog pass through to Dante Input Routers 1 4 WITH INPUT MUTES...

Страница 16: ...io along with control data Note If using Dante audio in the network the audio traffic needs to be filtered from reaching the wireless links 13 1 2 Networkconfiguration Frames are configured by default...

Страница 17: ...re all frames are powered on and connected through a wired network 2 Launch the Lake firmware update utility LakeUpdate exe 3 Select the appropriate product range 4 If more than one network adapter is...

Страница 18: ...e menu bar at the bottom of the screen to access the Module Menu and scroll bar 6 On the Module scroll bar the frame is represented with a frame containing four discs These are labeled A B C and D eac...

Страница 19: ...displays a block diagram for the Modules Tapping the different blue blocks will access the configuration screens for Input mixer Levels Input EQ Delay and Output EQ Crossover respectively The magnify...

Страница 20: ...the Events and Control dialog with the return button and return to the main area by tapping the I O Config EXIT button Levels Control Drag sliders and tap mute buttons for module input and output cha...

Страница 21: ...ms modules can be placed in groups Groups menu from the MAIN page for control of multiple units 13 4 RationalPowerManagement Rational Power Management RPM is a unique Lab gruppen feature that allows f...

Страница 22: ...are allows users to create an advanced custom power allocation scheme Switching to Custom mode disables the Automatic mode When RPM is active an RPM icon will be displayed next to the Actual ISVPL val...

Страница 23: ...ues but protection might be compromised No load monitoring Restart device if not cleared it needs service Fault A D converter power supply fault A D PSU FAULT Voltage supply to the analog input conver...

Страница 24: ...ds service Fault Mains voltage above 400 volt peak MAINS 400 VPK Power supply detects mains voltage above 400 volt peak Protective shut down auto restart attempt Check mains distribution connection Fa...

Страница 25: ...rature Improve cooling or reduce output power to avoid temperature becoming critical Fault Temp Fault amplifier channel TEMP FAULT Amplifier channel has reached internal protection limit Automatically...

Страница 26: ...cessing Up to 4 modules of Classic linear phase FIR cross over EQ delay LimiterMax peak and RMS limiters Up to 4 modules of Classic linear phase FIR cross over EQ delay LimiterMax peak and RMS limiter...

Страница 27: ...AC 45 66 Hz 100 240 V AC 45 66 Hz Operating voltage 70 265 V AC 70 265 V AC Mains wall plug NEMA L5 30 Twist lock 125 V 30 A and CEE 7 7 Schuko 230 V 16 A NEMA L5 30 Twist lock 125 V 30 A and CEE 7 7...

Страница 28: ...by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequential damages...

Страница 29: ...ation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect 3...

Страница 30: ...30 PLM SERIES QuickStartGuide rev1 0 0 Notes Notes...

Страница 31: ...31 PLM SERIES QuickStartGuide rev1 0 0 Notes Notes...

Страница 32: ...product specification is subject to change RPM R SMPS PFC CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB All other trademarks re...

Отзывы: