11. Product overview

PLM+ SERIES  Quick Start Guide  rev 1.0.0

13

    

11.2. Rear panel 

1

2

3

4

INPUT 1

INPUT 2

INPUT 3

AES/EBU

INPUT 1-2

INPUT 3-4

SEC

PRIM

Must be grounded/earthed

Made in Sweden

PIN 1: SCRN 2: POS 3: NEG

ANALOG WITH 

I

SO-

F

LOAT 

TM

50-60Hz

100-240V      2400-2950W

Ser. N:o

Removed!

CH 

2

CH 

1

CH 

4

CH 

3

SPEAKER OUTPUTS

CLASS  3 WIRING

BRIDGE

BRIDGE

INPUT 4

SWITCHED  00/ 000 Base-TX

1 1

1Gbps

1Gbps

LINK

ACT

LINK

ACT

PLM 2K44

1

1+/- CH 1+/-
2+/- CH 2+/-

1+/- CH 1+/-
2+/- CH 2+/-

3+/- CH 3+/-
4+/- CH 4+/-

1+/- CH 3+/-
2+/- CH 4+/-

CLASS 3

WIRING

BRIDGE CH 1 & 2:

1+:+

2- : -

BRIDGE CH 3 & 4: 1+ : +, 2- : -

SPEAKER OUTPUTS

INPUT 1

INPUT 2

INPUT 3

AES/EBU

INPUT 1-2

INPUT 3-4

SEC

PRIM

Must be grounded/earthed

Made in Sweden

PIN 1: SCRN 2: POS 3: NEG

ANALOG WITH 

I

SO-

F

LOAT 

TM

50-60Hz

100-240V      2400-2950W

INPUT 4

SWITCHED  00/ 000 Base-TX

1 1

1Gbps

1Gbps

LINK

ACT

LINK

ACT

PLM 2K44

1

7

5

6

Input Connectors

1

  Analog Inputs

 – Four analog inputs are available on standard XLR-3F connectors, electronically balanced and 

featuring Lake Iso-Float circuitry. Impedance is 20 kohms; maximum input level is +26 dBu.

2

  AES3 Inputs

 – Two latching XLR-3F connectors accept four channels of AES3 digital audio. Input impedance 

is 110 ohms; ensure that 110 ohm digital audio cables are used.

Output Connectors

Your device will be equipped with one of the two output connector options. Both options allow for Bridge Mode 
operation, which is activated in the Lake Controller software. Please refer to the Lake Controller Operation Manual 
for more information.

3

  Binding Posts

 – Power outputs are available on four separate pairs of fully enclosed binding posts.

4

  speakON connectors

 – Power outputs are available simultaneously on a single 8-pole connector and on two 

4-pole connectors. The four-pole connectors carry outputs for channels 1&2 and 3&4 respectively.

Ethernet and Power Connectors

5

 Primary Network Connector

 – The primary Neutrik RJ45 etherCON® connection provides integration into 

an Ethernet control network which may include other Lake Processors and the Lake Controller software. Network 
connection permits full control of all functions along with real-time metering from a remote position. This device 
supports the Dante audio networking protocol for multichannel, high-definition digital audio over the same Ethernet 
connection.

speakON version

Содержание PLM 12K44

Страница 1: ...PLM SERIES PoweredLouspeakerManagement System Rev 1 0 0 Quick Start Guide PLM 20K44 PLM 12K44 Item no QSG PLM SERIES Incorporating technologies from...

Страница 2: ...risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases a...

Страница 3: ...for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules...

Страница 4: ...responsibility 3 3 4 1 Mains connection grounding 3 3 4 2 Speaker output hazard on amplifiers 3 3 4 3 Radio interference 3 3 4 4 Speaker damage 3 3 4 5 Maintenance 3 5 Introduction 6 5 1 Welcome 6 6 F...

Страница 5: ...etup 16 13 1 1 Network connections topology 16 13 1 2 Network configuration 16 13 2 Software installation and firmware update 17 13 2 1 Lake Controller software suite 17 13 2 2 CAF software 17 13 2 3...

Страница 6: ...l Power Management RPM True flexibility in allocating power output across each channel to match requirement for more efficient use of amplifier inventory Any channel is capable of delivering up to 590...

Страница 7: ...ddleware 7 Installation 7 1 Unpacking Carefully open the shipping carton and check for any damage to the device or the supplied accessories Every Lab gruppen product is tested and inspected before lea...

Страница 8: ...rack 7 2 1 RearMounting Two rear support brackets along with associated mounting hardware are included with the PLM device It is strongly recommended that these are used wherever possible Fit the bra...

Страница 9: ...r more PLM devices in a rack with other fan cooled equipment confirm that all other equipment also uses front to rear airflow for cooling If this precaution is not observed there is a risk of overheat...

Страница 10: ...plifiers nominal voltage range Connecting the amplifier in three phase delta configuration In three phase configuration where the phases are 120 degrees apart one can connect three balanced loads in a...

Страница 11: ...10 2 1 1 Handles Handles should be used when carrying and when fitting into or removing from a rack Ensure that rack doors or covers have sufficient depth to clear the handles 2 Dust Filters Two dust...

Страница 12: ...er view The four LEDs display mute status red mute green unmute as well as fault and warning indications Global faults and warnings are indicated by simultaneous illumination of all four LEDs Please r...

Страница 13: ...3 Inputs Two latching XLR 3F connectors accept four channels of AES3 digital audio Input impedance is 110 ohms ensure that 110 ohm digital audio cables are used Output Connectors Your device will be e...

Страница 14: ...iguration is required for a dual redundant network setup See the Lake Controller Operation Manual for further details Note Do not create a closed loop when configuring multiple devices in an Ethernet...

Страница 15: ...ing ISVPL limiter RPM and load monitoring 5 Power Amplifier INPUTS Dante Receivers 1 8 AES 1 4 Analog 1 4 OUTPUTS Dante 1 8 no mutes AES Analog pass through to Dante Input Routers 1 4 WITH INPUT MUTES...

Страница 16: ...io along with control data Note If using Dante audio in the network the audio traffic needs to be filtered from reaching the wireless links 13 1 2 Networkconfiguration Frames are configured by default...

Страница 17: ...re all frames are powered on and connected through a wired network 2 Launch the Lake firmware update utility LakeUpdate exe 3 Select the appropriate product range 4 If more than one network adapter is...

Страница 18: ...e menu bar at the bottom of the screen to access the Module Menu and scroll bar 6 On the Module scroll bar the frame is represented with a frame containing four discs These are labeled A B C and D eac...

Страница 19: ...displays a block diagram for the Modules Tapping the different blue blocks will access the configuration screens for Input mixer Levels Input EQ Delay and Output EQ Crossover respectively The magnify...

Страница 20: ...the Events and Control dialog with the return button and return to the main area by tapping the I O Config EXIT button Levels Control Drag sliders and tap mute buttons for module input and output cha...

Страница 21: ...ms modules can be placed in groups Groups menu from the MAIN page for control of multiple units 13 4 RationalPowerManagement Rational Power Management RPM is a unique Lab gruppen feature that allows f...

Страница 22: ...are allows users to create an advanced custom power allocation scheme Switching to Custom mode disables the Automatic mode When RPM is active an RPM icon will be displayed next to the Actual ISVPL val...

Страница 23: ...ues but protection might be compromised No load monitoring Restart device if not cleared it needs service Fault A D converter power supply fault A D PSU FAULT Voltage supply to the analog input conver...

Страница 24: ...ds service Fault Mains voltage above 400 volt peak MAINS 400 VPK Power supply detects mains voltage above 400 volt peak Protective shut down auto restart attempt Check mains distribution connection Fa...

Страница 25: ...rature Improve cooling or reduce output power to avoid temperature becoming critical Fault Temp Fault amplifier channel TEMP FAULT Amplifier channel has reached internal protection limit Automatically...

Страница 26: ...cessing Up to 4 modules of Classic linear phase FIR cross over EQ delay LimiterMax peak and RMS limiters Up to 4 modules of Classic linear phase FIR cross over EQ delay LimiterMax peak and RMS limiter...

Страница 27: ...AC 45 66 Hz 100 240 V AC 45 66 Hz Operating voltage 70 265 V AC 70 265 V AC Mains wall plug NEMA L5 30 Twist lock 125 V 30 A and CEE 7 7 Schuko 230 V 16 A NEMA L5 30 Twist lock 125 V 30 A and CEE 7 7...

Страница 28: ...by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequential damages...

Страница 29: ...ation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect 3...

Страница 30: ...30 PLM SERIES QuickStartGuide rev1 0 0 Notes Notes...

Страница 31: ...31 PLM SERIES QuickStartGuide rev1 0 0 Notes Notes...

Страница 32: ...product specification is subject to change RPM R SMPS PFC CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB All other trademarks re...

Отзывы: