Lab.gruppen LAB 1600 Скачать руководство пользователя страница 9

• 

When the clip limiter is engaged it flickers 
briefly. 

• 

When the clip limiter is not engaged it lights for 
a longer period. 

 

The remaining yellow LEDs indicate if any 
protection circuits are activated. These are described 
below. 
 

 
 
Protection features 

Each LAB.GRUPPEN amplifier has many advanced 
protection features, that will protect both the 
amplifier and the speakers connected to it, should a 
fault condition arise. Under normal use these features 
are inaudible. All protection circuits are independent. 
 

Clip limiter  

The clip limiter is included to prevent dangerous clip 
signals reaching the speaker and damaging it. It 
works by monitoring the output and comparing the 
distortion produced between the input and output of 
the amplifier. If the distortion exceeds 1%THD for 
any reason ( voltage or current clipping), the limiter 
reduces the input signal proportionally. Note that, if 
the signal is distorted or clipped  before it reaches the 
amplifier, the clip limiter will not be activated. 
Under normal operation the clip limiting is inaudible. 
The limiter can be turned On or Off by depressing 
the relevant clip limit switch (2). Some 
manufacturers of Loudspeaker processors do not 
recommend the use of clip limiters in amplifiers, as 
they tend to upset the tracking of the processor’s 
limiters. 
Apart from this one exception, 

LAB.GRUPPEN 

recommend leaving the clip limiters switched "on" 
(button depressed).

 

As a by-product, when the amplifier comes out of a 
protect condition, the output level has a slow rise 
time -the effect is like turning the gain up slowly. 

 

Thermal protection 

When the amplifier is driven very hard into low 
impedance, the cooling fans go into high speed. If the 
conditions that cause this continue, the temperature 
indicator(s) will light as an indication that the 
amplifier will soon thermal out.  
After five seconds the amplifier will go into thermal 
protect, by muting the input signal. After 15-20 
seconds the amplifier will cool down the 

Intercooler

®

and the cycle will begin again. 

Thermal protection starts when the I

ntercooler

® 

reaches a temperature above 90

0

 C 

 
 
 

VHF protection 

When a signal of more than 12kHz, at full output 
power, is present at the output connectors for more 
than five seconds, the VHF protection mutes the 
input signal (this is indicated on the front panel (4) 
labeled PROTECT). After five seconds the cycle 
starts again.  
This is a useful feature as there are currently no  
commercially available compression drivers that can 
take 500 watts of power at 10 kHz!! this circuit is 
inaudible under normal use, however it can be turned 
off. 

If the VHF protection is required to be turned off i.e. 
for studio monitors, please consult your supplier, as 
this is a non-user adjustment

 

Short circuit protection

 

All LAB.GRUPPEN amplifiers are completely 
short circuit protected. The protection circuit 
permits very high peak currents, but still holds the 
output devices within the safe operation area. If a 
short circuit is maintained, the channel affected will 
eventually go into thermal protection and the cycle 
will start again.  
The LAB 1600 is equipped with LAB.GRUPPEN’s 

Adaptive limiting system (ALS

TM

).

 The 

ALS

TM

 

circuit continuously monitors the supply rails, and 
limits the current going to the output transistors. If 
the 

ALS

TM

 

is activated the input signal is muted, 

and the yellow LED labeled ”PROTECT” will light. 
 

AC mains voltage protection 

 

If the AC mains voltage is outside the allowed 

operation voltage ( over or under voltage) , the 
power supply will shut down itself. When the 
mains voltage is above the minimum start voltage 
and below its maximum operating voltage the 
amplifier will restart again.  

 

It takes a couple of seconds to check its circuits 

(this is known as the "soft start" or "slow start" 
sequence), the gain will slowly and gradually raised 
back to normal, and the fans then blow at high speed 
before going onto "idle". The two green ”ON” 
LED’s indicate when then power supply is 
operating properly.

 

9

Содержание LAB 1600

Страница 1: ...reverse Operation 8 1 Operation precautions 2 Powering up Soft start 3 Input attenuators 4 Gain switch 5 Indicators Protections 9 1 Clip limiter 2 Thermal protection 3 VHF protection 4 Short circuit p...

Страница 2: ...th loudspeakers and humans alike Many loudspeakers can be easily damaged or destroyed by overpowering especially with the high power available from a bridged amplifier Always check the speakers contin...

Страница 3: ...C The indicator first comes on as a warning to either turn down the input level or check the cooling arrangements after which point the amplifier will mute the input signal When the cooling fans have...

Страница 4: ...between the fans and heat sink and this only works in one direction of the air flow see Design features on page 8 Should a heat sink get too hot its sensing circuit will mute the hot channel If the p...

Страница 5: ...standard IEC 65 and used by a majority of safety agencies The normal operating power is measured using pink noise with an average output power equal to 1 8 of full power The one eighth of the total p...

Страница 6: ...se balanced inputs whenever possible Figure 8 Balanced line with unbalanced equipment 7 Connecting speakers Speaker connections are made via the two Neutrik NL4FC Speakon connectors 1 They are the onl...

Страница 7: ...ms per channel 2 Tandem mono For tandem dual channel single input operation depress the Link switch Both channels can now be driven by a signal at either input connector The output connection is the s...

Страница 8: ...ier it takes a couple of seconds to check its circuits this is known as the soft start or slow start sequence the fans then blow at high speed before going onto idle and the two bottom green LED s com...

Страница 9: ...rotect by muting the input signal After 15 20 seconds the amplifier will cool down the Intercooler and the cycle will begin again Thermal protection starts when the Intercooler reaches a temperature a...

Страница 10: ...cs as a conventional supply We have avoided the pitfalls of push pull converters by eliminating the need for limiting on the secondary side of the switch transformer This is achieved by using sense wi...

Страница 11: ...h the cables to the unit Electromagnetic fields up to 3 V m radiated on the unit and the cables in the frequency range of 27 500 MHz We have extended the tests in two cases and chosen a standard used...

Страница 12: ...ide of the amplifier These conditions usually occur after prolonged use in environments using cracked oil smoke machines If you are using your amplifier for heavy duty use i e concert touring or indus...

Страница 13: ...3 LAB GRUPPEN shall not be responsible for any incidental or consequential damages with respect to the products warranted LAB GRUPPEN reserve the right to make changes or improvements in design or ma...

Отзывы: