Lab.gruppen LAB 1600 Скачать руководство пользователя страница 4

Please refer to diagram on page 3 

 
1. Speaker 

connector 

  This type of speaker connector may be 
unfamiliar to some users. A full description is found 
in the operation section. (See page 6). 

 

 

2.  Clip limiter switch. 

 

Turns the clip limiter on and off. 

 

 

3. Input 

jack 

 

Alternative to using input XLR or for linking 

inputs with other amplifiers. (See page 5). 

 

 

4. 

Input  signal XLR 

(See page 5). 

 

 

5.  Phase reverse switch for channel B 

 

For reversing the input signal phase of channel 

B to allow bridged operation. (See page 7). 

 

 

 

 

6. Link 

switch 

 

Allows a single input to drive both channels 

simultaneously. (See page 7). 
 

 

7.  Gain select switch 

 

Allows amplifier gain to be switched between 

29dB and its normal gain at 0.775mV input 
sensitivity. (See page 7). 

 

 

8. 

AC line cord 

(See page 5) 

 

 

9.  Minimum load selector (MLS™) switch 

This switch is used to select the minimum nominal 
speaker impedance the amplifier is going to drive. 
A LED is indicating if the 2ohms position is 
selected. (See page 7). 

 
 

Installation 

1. Mounting 

The amplifier is two rack units high (2U) and will 
mount in a standard EIA 19 inch rack. Amplifiers 
may be stacked directly on top of each other. There 
is no need for spacing between units. If it is the 
intention to fill a rack with amplifiers, we 
recommend racking is started from the bottom of 
the rack. It is also recommended that rear supports 
are used for amplifiers mounted in the middle of the 
rack, especially if used as part of a portable system. 
 

2.  

Cooling 

Your amplifier uses forced air cooling system to 
maintain a low and even operating temperature. All 
LAB.GRUPPEN amplifier, which are fan 
ventilated, have front to rear cooling. There are 
several reasons for this, one is that there's usually 
cooler air outside the rack than inside and therefore 
the amplifiers can run at higher continuos power 
levels without thermal problems. Never try to 
reverse the air flow, as the Intercooler® need a 
pressure chamber between the fans and heat sink, 
and this only works in one direction of the air flow 
(see Design features on page 8).

 

Should a heat sink get too hot, its sensing circuit 
will mute the hot channel. If the power supply 
overheats, another sensing circuit will mute all 
output channels, until it cools down to a safe 
operating temperature. 
Make sure that there is an adequate air supply in 
front of the amplifier and that the rear of the 
amplifier has sufficient space to allows the exhaust 
to escape. If the amplifier is rack mounted, do not 
use covers or doors on the front or rear of the rack.  
For fixed installations with a central cooling 
system, usually found in fixed installations with a 
dedicated rack room, it may be necessary to 

calculate the maximum heat emission. Refer to 
Power consumption on page 5. 

 
3.   Operating voltage 

A label just below the mains cable on the rear of 
the amplifier indicates the AC mains voltage, for 
which the amplifier is wired. Connect the power 
cable only to the AC source referred to on the label. 
The warranty will not cover damage caused by 
connecting to the wrong type of AC mains. 
For converting a 230 volt amplifier to 115 volt or 
vice-versa, see Appendix A.  
LAB.GRUPPEN switch mode amplifier use 
primary switching, i.e. the mains is rectified 
directly before the transformer, which means that 
the power supply is insensitive to the mains 
frequency and will operate from DC to 400 Hz. 
The amplifier is supplied with an approved European 
AC line connector. If this connector is not 
appropriate for your country, it can be cut off and 
wired to a suitable connector in the following way : 
 

BROWN   LIVE 
 
BLUE 

  NEUTRAL 

 
GREEN/YELLOW EARTH 

 
Once the AC connector is connected to a suitable AC 
supply, the amplifier can be started with the AC 
actuator.  
When you power up the amplifier it takes a couple of 
seconds to check its circuits (this is known as the 
"soft start" or "slow start" sequence), the fans then 
blow at high speed before going onto "idle" and the 2 
bottom green LED’s come on to show the output 
circuits are receiving the correct rail voltage. 

 
4.   Grounding 

 

4

Содержание LAB 1600

Страница 1: ...reverse Operation 8 1 Operation precautions 2 Powering up Soft start 3 Input attenuators 4 Gain switch 5 Indicators Protections 9 1 Clip limiter 2 Thermal protection 3 VHF protection 4 Short circuit p...

Страница 2: ...th loudspeakers and humans alike Many loudspeakers can be easily damaged or destroyed by overpowering especially with the high power available from a bridged amplifier Always check the speakers contin...

Страница 3: ...C The indicator first comes on as a warning to either turn down the input level or check the cooling arrangements after which point the amplifier will mute the input signal When the cooling fans have...

Страница 4: ...between the fans and heat sink and this only works in one direction of the air flow see Design features on page 8 Should a heat sink get too hot its sensing circuit will mute the hot channel If the p...

Страница 5: ...standard IEC 65 and used by a majority of safety agencies The normal operating power is measured using pink noise with an average output power equal to 1 8 of full power The one eighth of the total p...

Страница 6: ...se balanced inputs whenever possible Figure 8 Balanced line with unbalanced equipment 7 Connecting speakers Speaker connections are made via the two Neutrik NL4FC Speakon connectors 1 They are the onl...

Страница 7: ...ms per channel 2 Tandem mono For tandem dual channel single input operation depress the Link switch Both channels can now be driven by a signal at either input connector The output connection is the s...

Страница 8: ...ier it takes a couple of seconds to check its circuits this is known as the soft start or slow start sequence the fans then blow at high speed before going onto idle and the two bottom green LED s com...

Страница 9: ...rotect by muting the input signal After 15 20 seconds the amplifier will cool down the Intercooler and the cycle will begin again Thermal protection starts when the Intercooler reaches a temperature a...

Страница 10: ...cs as a conventional supply We have avoided the pitfalls of push pull converters by eliminating the need for limiting on the secondary side of the switch transformer This is achieved by using sense wi...

Страница 11: ...h the cables to the unit Electromagnetic fields up to 3 V m radiated on the unit and the cables in the frequency range of 27 500 MHz We have extended the tests in two cases and chosen a standard used...

Страница 12: ...ide of the amplifier These conditions usually occur after prolonged use in environments using cracked oil smoke machines If you are using your amplifier for heavy duty use i e concert touring or indus...

Страница 13: ...3 LAB GRUPPEN shall not be responsible for any incidental or consequential damages with respect to the products warranted LAB GRUPPEN reserve the right to make changes or improvements in design or ma...