Introduction 

Thank you for purchasing a LAB.GRUPPEN power amplifier. This manual contains important information on 
operating your amplifier correctly and safely. Please take some time and read this manual to familiarize yourself 
with the amplifier. 
 

The front panel 

Figure 1. Front panel 
 

1. Carry/protection 

handle 

 

Both handles can be used to carry the amplifier, 

they also act as protection for the front panel. If so 
desired they can be removed (by removing the 
screws behind the front panel) for fixed installations, 
or racks where the front covers are to shallow.  
 

 

2.  Input level attenuators 

 

These controls are used to alter the signal level 

entering the amplifier. They are calibrated in dB to 
help set up active loudspeaker systems or cut down 
unwanted noise from the input signal.  
 

(See page 8). 

 

 

3.  Over temperature protect indicator. 

 

This indicator is lit if the amplifier tries to 

operate above its maximum operating 
temperature(90

o

C). The indicator first comes on as a 

warning to either turn down the input level or  check 
the cooling arrangements after which point the 
amplifier will mute the input signal. When the 
cooling fans have returned the output heat sinks to 
the normal operating temperature the input signal is 
unmuted.

 

 

 

4.  Protection indicator (VHF and short circuit) 

 

This indicator is lit if the short circuit protection 

is activated. 
 

 This indicator also lights when constant signals, 

above 12 kHz at full power, are present at the output 
terminals. When this happens the input signal is 
muted and the process cycles until the VHF signal is 
no longer present. (See page 9). 
 

 

5.     Clip/limit indicator 

 

This indicator tells when the amplifier output is 

clipping or limiting. The two different states can be 
told apart: 

• 

When the clip limiter is engaged it flickers 
briefly. (See page 8). 

• 

When the clip limiter is not engaged it lights for 
a longer period.  

 
6.     Fan grill filter

 

 A foam filter is located behind the front panel to 

prevent dust entering the amplifier. 

 
7.     Power actuator 

 

This is used to start the amplifier.  

(See page 4 and 8) 
 

The rear panel 

 

Figure 2. Rear panel 

 

 

3

Содержание LAB 1600

Страница 1: ...reverse Operation 8 1 Operation precautions 2 Powering up Soft start 3 Input attenuators 4 Gain switch 5 Indicators Protections 9 1 Clip limiter 2 Thermal protection 3 VHF protection 4 Short circuit p...

Страница 2: ...th loudspeakers and humans alike Many loudspeakers can be easily damaged or destroyed by overpowering especially with the high power available from a bridged amplifier Always check the speakers contin...

Страница 3: ...C The indicator first comes on as a warning to either turn down the input level or check the cooling arrangements after which point the amplifier will mute the input signal When the cooling fans have...

Страница 4: ...between the fans and heat sink and this only works in one direction of the air flow see Design features on page 8 Should a heat sink get too hot its sensing circuit will mute the hot channel If the p...

Страница 5: ...standard IEC 65 and used by a majority of safety agencies The normal operating power is measured using pink noise with an average output power equal to 1 8 of full power The one eighth of the total p...

Страница 6: ...se balanced inputs whenever possible Figure 8 Balanced line with unbalanced equipment 7 Connecting speakers Speaker connections are made via the two Neutrik NL4FC Speakon connectors 1 They are the onl...

Страница 7: ...ms per channel 2 Tandem mono For tandem dual channel single input operation depress the Link switch Both channels can now be driven by a signal at either input connector The output connection is the s...

Страница 8: ...ier it takes a couple of seconds to check its circuits this is known as the soft start or slow start sequence the fans then blow at high speed before going onto idle and the two bottom green LED s com...

Страница 9: ...rotect by muting the input signal After 15 20 seconds the amplifier will cool down the Intercooler and the cycle will begin again Thermal protection starts when the Intercooler reaches a temperature a...

Страница 10: ...cs as a conventional supply We have avoided the pitfalls of push pull converters by eliminating the need for limiting on the secondary side of the switch transformer This is achieved by using sense wi...

Страница 11: ...h the cables to the unit Electromagnetic fields up to 3 V m radiated on the unit and the cables in the frequency range of 27 500 MHz We have extended the tests in two cases and chosen a standard used...

Страница 12: ...ide of the amplifier These conditions usually occur after prolonged use in environments using cracked oil smoke machines If you are using your amplifier for heavy duty use i e concert touring or indus...

Страница 13: ...3 LAB GRUPPEN shall not be responsible for any incidental or consequential damages with respect to the products warranted LAB GRUPPEN reserve the right to make changes or improvements in design or ma...

Отзывы: