FP+ Series Operation Manual
29
APPENDIX 8
FP 10000Q
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby, with remote power off via NomadLink
0
0
0
0
0
Powered on, idling
139
0
139
475
120
Amp (I)
Watt
Pink noise (1/8
rated power)
16
Ω
/ Ch.
660 x 4
10.7
5.6
732
330
402
1371
345
32
Ω
/ Bridged
1320 x 2
8
Ω
/ Ch.
1300 x 4
16.9
8.8
1224
650
574
1958
493
16
Ω
/ Bridged
2600 x 2
4
Ω
/ Ch.
2100 x 4
25.9
13.5
1914
1050
864
2949
743
8
Ω
/ Bridged
4200 x 2
2
Ω
/ Ch.
2500 x 4
32.2
16.8
2414
1250
1164
3973
1001
4
Ω
/ Bridged
5000 x 2
Pink noise (1/4
rated power)
*3)
16
Ω
/ Ch.
660 x 4
13.6
7.1
1143
880
263
897
226
32
Ω
/ Bridged
1320 x 2
8
Ω
/ Ch.
1300 x 4
22.4
11.7
2096
1733
363
1238
312
16
Ω
/ Bridged
2600 x 2
4
Ω
/ Ch.
2100 x 4
39.4
20.6
3589
2800
789
2691
678
8
Ω
/ Bridged
4200 x 2
2
Ω
/ Ch.
2500 x 4
52.9
27.6
4159
3333
825
2817
710
4
Ω
/ Bridged
5000 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Nema L5-30P Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specifi ed here is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum power before amplifi er protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be
tripped even if operation is in excess of max. ratings.
FP 6000Q
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby, with remote power off via NomadLink
0
0
0
0
0
Powered on, idling
134
0
134
456
115
Amp (I)
Watt
Pink noise (1/8
rated power)
16
Ω
/ Ch.
320 x4
6.9
3.5
423
160
263
898
226
32
Ω
/ Bridged
640 x2
8
Ω
/ Ch.
625 x4
10.9
5.4
700
313
388
1323
333
16
Ω
/ Bridged
1250 x2
4
Ω
/ Ch.
1250 x4
18.0
9.0
1215
625
590
2015
508
8
Ω
/ Bridged
2500 x2
2
Ω
/ Ch.
1500 x4
22.8
11.4
1575
750
825
2817
710
4
Ω
/ Bridged
3000 x2
Pink noise (1/4
rated power)
*3)
16
Ω
/ Ch.
320 x4
11.8
5.9
771
427
344
1175
296
32
Ω
/ Bridged
640 x2
8
Ω
/ Ch.
625 x4
20.0
10.0
1402
833
569
1942
489
16
Ω
/ Bridged
1250 x2
4
Ω
/ Ch.
1250 x4
37.3
18.6
2748
1667
1081
3690
930
8
Ω
/ Bridged
2500 x2
2
Ω
/ Ch.
1500 x4
38.9
19.4
2872
2000
872
2977
750
4
Ω
/ Bridged
3000 x2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Nema L5-30P Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specifi ed here is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum power before amplifi er protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be
tripped even if operation is in excess of max. ratings.