6. Installation
10
D SERIES Lake Operation Manual rev 3.0.4
6. Installation
10
D SERIES Lake Operation Manual rev
3
.0.
3
6.2.2. Mounting front grille
The front grille is shipped on top of the amplifier inside the box to protect it during shipping. The front grille adheres
to the amplifier with magnets. Hold the front grille with your fingers in each of the side cutouts and slide it gently into
place straight from the front.
NOTE: Always ensure the dust filters behind the detachable front panel are clean to ensure maximum
possible airflow. The exterior front panel is held in place by powerful magnets but is easy to detach by
using your fingers in the openings at the each side. To clean the foam filter, detach it from the exterior
front and gently use a vacuum cleaner or gently shake it. Remount with the opposite procedure. Never
operate the amplifier without the dust filter installed.
6.3. Cooling and fan operation
D Series devices use a forced–air cooling system with airflow from front to rear, allowing high continuous power
levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or
lids are placed at the front or rear of the rack. Never attempt to reverse the airflow. Make sure an adequate air
supply is provided in front of the D Series device, and that the rear of the device has sufficient space to allow
air to escape. It is recommended to keep the ambient temperature around the device as cool as possible. An
increased temperature can have a significant negative impact on the expected lifetime on the components
inside the D Series device.
NOTE: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation. Leaving
gaps in between items of equipment degrades the effectiveness of forced–air cooling.
If installing one or more D Series devices in a rack with other fan–cooled equipment, confirm that all other
equipment also uses front–to–rear airflow for cooling. If this precaution is not observed, there is a risk of
overheating, as units with the reverse airflow will be drawing in air which has already been heated by the
D Series devices.
The D Series device is equipped with a sophisticated temperature sensing system which protects it from any
overheating which may occur as a result of inadequate ventilation.
6.4. Operating voltage
D Series has a universal power supply and its mains nominal and operating voltages are specified in the Technical
Specifications. D Series can be ordered with a variety of mains plugs. If the mains plug (AC plug) fitted to the mains
cable (AC cord) is not appropriate for your country it can be removed and a locally–sourced one fitted instead. If
you are not 100% confident of your competence to replace the mains plug (AC plug), the task should be carried
out by qualified personnel.
NOTE: In–rush current is controlled and limited during the soft–start sequence. This enables multiple D
Series Devices on the same AC mains circuit to be turned on simultaneously.