Laars newport Скачать руководство пользователя страница 2

Page 2

 

LAARS Heating Systems

TABLE OF CONTENTS

SECTION 1.
General Information

1.1        Boiler Installation ........................................... 3
1.2        Freight Claims ............................................... 3
1.3        Boiler Location............................................... 3
1.4        Boiler Clearances (to combustibles).............. 3
1.5        Floor .............................................................. 3
1.6        Combustion and Ventilation Air ..................... 3
1.7        Chimney and Draft Requirements ................. 3
1.8        Jacket (normally fi tted) .................................. 4
1.9        Oil Burner (normally fi tted)............................. 4
1.10      Installation of Alternate Nozzles
                for Higher Output ........................................ 4
1.11      Boiler Controls (normally fi tted) ..................... 3
1.12      Oil .................................................................. 3
1.13      Oil Storage and Pipe Layout.......................... 3

1.14      Electrical Wiring............................................. 4
1.15      Operation 
                (Honeywell L.8124A or L7224A aquastat        
                relay)........................................................... 4
1.16      Domestic Water Piping .................................. 4
1.17      Cleaning the Boiler ........................................ 5
1.18      Cleaning the Chimney ................................... 6
1.19      Servicing the Burner ...................................... 6
1.20      Maintenance of the Tankless Coil ................. 6
1.21      Coil Removal ................................................. 6

SECTION 2.
Replacement Parts

2.1        Ordering Information.................................... 11
2.2        Parts List...................................................... 11

OUT OF

PRODUCTION

Содержание newport

Страница 1: ...ich could cause serious injury property damage or death Improper installation and or operation will void the warranty WARNING If the information in this manual is not followed exactly a fire or explos...

Страница 2: ...er normally fitted 4 1 10 Installation of Alternate Nozzles for Higher Output 4 1 11 Boiler Controls normally fitted 3 1 12 Oil 3 1 13 Oil Storage and Pipe Layout 3 1 14 Electrical Wiring 4 1 15 Opera...

Страница 3: ...gnee 1 3 Boiler Location The boiler should be positioned as near to the chimney as possible and have a minimum smoke pipe connector length of 18 457mm CAUTION Newport boilers must not be directly conn...

Страница 4: ...unit Important Refer to burner pump instructions for detailed fuel line and pump usage information All installations must conform to local and national codes See Figures 5A and 5B Figure 5A One pipe...

Страница 5: ...tire flue and venting system inspected 1 17 Cleaning the Boiler To maintain the high thermal efficiency and a long life from your boiler it should be cleaned at least once a year preferably at the end...

Страница 6: ...be causing a blockage 1 19 Servicing the Burner This should only be carried out by a trained and licensed service technician in accordance with the burner maker s instructions 1 20 Maintenance of the...

Страница 7: ...35 133 30 150 44 160 47 177 52 Output MBTU hr kW 90 26 105 30 116 34 130 38 139 40 154 48 Efficiency AFUE 83 6 83 1 83 1 83 7 83 0 83 0 Net Stack Temperature F C 312 156 353 178 371 188 351 177 386 1...

Страница 8: ...front panel 3 with screws 2 Slide assembled jacket over boiler and secure side panels to base tray 3 Fix rear panel 4 to sides 4 Adjust corner brackets 5 on heat exchanger so they touch inside of jack...

Страница 9: ...rmation Air vent Fill pipe Valve Figure 5A 1 min Oil tank H Filter P Burner Boiler Air vent 1 min Fill pipe Oil tank Figure 5B Valve Filter Burner Boiler H PIPE LENGTHS H One Pipe Gravity System 3 8 O...

Страница 10: ...verload protection as required 24V Room Thermostat 1K L1 Hot Power Supply 120V L2 Circulator Switch Low Limit Circulator Hi Limit 1K2 Oil Burner Relay Heating Circulator AQUASTAT RELAY L8124A 1K1 WIRI...

Страница 11: ...85 110 Use with P N 51 056 51 090 Flue Cover Assembly 85 110 52 108 Front Panel Assembly 85 110 52 116 Left Panel Assembly 85 110 52 124 Right Panel Assembly 85 110 51 128 Top Panel Assembly 85 110 5...

Страница 12: ...Fax 800 559 1583 Customer Service Service Advisors 20 Industrial Way Rochester NH 03867 603 335 6300 Fax 603 335 3355 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130...

Отзывы: